If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 148-00. We hope that this HANNA INSTRUMENTS HI 148-00 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 148-00.
Manual abstract: user guide HANNA INSTRUMENTS HI 148-00
Detailed instructions for use are in the User's Guide.
[. . . ] If you need additional technical information, do not hesitate to email us at tech@hannainst. com. These instruments are in compliance with the CE directives.
SPECIFICATIONS HI 148-00
Range Resolution Accuracy Setpoint Hysteresis Alarm Sensor Environment Power supply Dimensions Weight -20. 0 to 60. 0ºC 0. 1ºC ±0. 5ºC Selectable from 0. 0 to 50. 0ºC ±0. 5ºC around setpoint LED blinks when measured temperature is higher than the setpoint Incorporated, encapsulated stainless steel -20 to 60ºC; RH 100% External 12 VDC (included) 86 x 94 x 33 mm (3. 3 x 3. 7 x 1. 3") 150 g (5. 2 oz. )
FUNCTIONAL DESCRIPTION
GENERAL DESCRIPTION
HI 148 is an indicator for the monitoring of food temperature in different production cycles. Constructed in a compact casing and with a molded eye, HI 148 can be installed on the QC bench or wherever necessary to control the ambient temperature of food chain, from the storage room to the point of delivery. [. . . ] This alarm is a cost-saving feature with a tremendous potential. It can be used as a forewarning that the refrigeration or air conditioning unit is malfunctioning, or that a door has been left open, or point to any other mishaps, common in a busy workplace. HI 148 is a convenient and very inexpensive way to ensure that temperature of the environment in which food is prepared, kept and served never varies too much from the limits imposed by the HACCP regulations. In fact , the meter frees workers from having to manually check the temperature and immediately signals if and when an abnormality arises. Celsius and Fahrenheit models are available.
These Instruments are in Compliance with the CE Directives
1. 12VDC power adapter (included)
OPERATIONAL GUIDE HI 148-01
Range Resolution Accuracy Setpoint Hysteresis Alarm Sensor Environment Power supply Dimensions Weight -4. 0 to 140. 0ºF 0. 1ºF ±0. 9ºF Selectable from 32. 0 to 122. 0ºF ±1ºF around setpoint LED blinks when measured temperature is higher than the setpoint Incorporated, encapsulated stainless steel -4 to 140ºF; RH 100% External 12 VDC (included) 86 x 94 x 33 mm (3. 3 x 3. 7 x 1. 3") 150 g (5. 2 oz. )
TAKING MEASUREMENTS
· Turn the meter on by connecting the 12 VDC power adapter to the meter and to the mains. · A value will appear on the LCD, to indicate the temperature. Wait a few minutes for the display to stabilize.
ADJUSTING THE SETPOINT
With HI 148 you can select your own setpoint and be alerted with a visual LED alarm when an abnormal situation arises. · Unscrew and remove the rear panel and gasket seal to access the MEASURE/SET switch.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. The meters are supplied with 12 VDC power adapter. Note: Conserve all packing material until the instrument has been observed to function correctly because any defective item must be returned to the Dealer in its original packing.
· Move the switch to the left (SET Mode).
· Replace the rear panel and the gasket, ensuring the unit is properly closed.
WARRANTY
HI 148-00/01 Thermometer are warranted for one year against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The sensor are warranted for a period of one year also. This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. [. . . ] During operation, ESD wrist straps should be worn to avoid possible damage to the probe by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use these instruments when voltage at the measurement surface exceed 24 VAC or 60 VDC. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 148-00
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 148-00 will begin.