User manual HANNA INSTRUMENTS HI 38061

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 38061. We hope that this HANNA INSTRUMENTS HI 38061 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 38061.


Mode d'emploi HANNA INSTRUMENTS HI 38061
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 38061

Detailed instructions for use are in the User's Guide.

[. . . ] Read the value in the result window directly in mg/L (or ppm) of Phosphate. To convert this result to mg/L (ppm) of Phosphorus, divide it by 3. 1. 2- Using the pipette, add to each glass vial 10 mL of sample (up to the mark). 10 mL www. hannainst. com SIGNIFICANCE AND USE Phosphorus occurs in natural waters and in wastewaters almost entirely as phosphates (PO43-). Large quantity of phosphate arise from laundering industries as it is used in many cleaning preparations, from soil runoff and sewage. [. . . ] If there is any noticeable damage, notify your Dealer or the nearest Hanna office immediately. Each kit is supplied with: · HI 93713-0 Reagent, packets (100 pcs); · Deionized Water, 1 bottle (500 mL); · 1 checker disc (including a mirror, a mirror holder , the 38061 and the 38073 discs); · 2 glass vials with caps; · 1 plastic pipette (3 mL); · 1 long plastic pipette. Note: Any damaged or defective item must be returned in its original packing materials. 10- Using the pipette, add to each glass vial 7. 5 mL of sample (up to the mark). 7. 5 mL 11- Insert one of them into the left hand opening of the checker disc. This is the blank. PRINTED IN ITALY CHEMICAL REACTION Adaptation of the ascorbic acid method. The reaction between phosphate and the reagent causes a blue tint in the sample. 5- Wait for 3 minutes to allow reaction to occur. 6- Remove the cap and insert the reacted sample into the right hand opening of the checker disc. 12- Add to the other glass vial 1 packet of HI 93713-0 Reagent. Replace the cap and shake vigorously for 20 seconds. This is the reacted sample. ISTR38061 13- Wait for 3 minutes to allow reaction to occur. 14- Remove the cap and insert the reacted sample into the right hand opening of the checker disc. 15- Hold the checker disc so that a light source illuminates the samples from the back of the windows. 21- Use the long plastic pipette to add deionized water up to the 7. 5 mL mark, replace the cap and swirl to mix. REFERENCES APHA, AWWA, WEF, Standard Methods for the Examination of Water and Wastewater, 18th edition, 1992 HEALTH AND SAFETY The chemicals contained in this kit may be hazardous if improperly handled. Read the relevant Health and Safety Data Sheet before performing this test. 16- Keep the checker disc at a distance of 30-40 cm (1216") from the eyes to match the color. Rotate the disc while looking at the color test windows and stop when you find the color match. 17- Read the value in the result window, divide it by 10 and record it in mg/L (or ppm) of Phosphate. To convert this result to mg/L (ppm) of Phosphorus, divide it by 3. 1. 0-50 ppm Phosphate (PO43-) Range: 18- Remove the mirror, if installed, and insert just the 38073 disc as shown in the figure. 7. 5 mL 19- Using the 3 mL pipette, add to one of the glass vials 5 mL of sample (up to the mark) and insert the vial into the left hand opening of the checker disc. [. . . ] When not in use, keep the disc protected from light, in a cool and dry place. Interferences: iron above 5 ppm; copper above 10 ppm; hydrogen sulfide, arsenate and highly buffered samples. 5 mL 20- Using the syringe, add to the other vial 0. 75 mL of sample. Note: To measure exactly 0. 75 mL of sample with the syringe, push the plunger completely into the syringe and insert the tip into sample. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 38061

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 38061 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag