If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 3815. We hope that this HANNA INSTRUMENTS HI 3815 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 3815.


Mode d'emploi HANNA INSTRUMENTS HI 3815
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 3815

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual Range SPECIFICATIONS 0 to 100 mg/L (ppm) Cl 0 to 1000 mg/L (ppm) Cl­ Smallest Increment 1 mg/L [in the 0-100 mg/L range] 10 mg/L [in the 0-1000 mg/L range] Analysis Method Mercuric nitrate titration Sample Size 5 mL and 50 mL Number of Tests 110 (average) Case Dimensions 200x120x60 mm (7. 9x4. 7x2. 4") Shipping Weight 460 g (1 lb. ) ­ INSTRUCTIONS READ ALL THE INSTRUCTIONS BEFORE USING THE TEST KIT LOOK AT THE BACK PAGE FOR THE ILLUSTRATED PROCEDURE High Range ­ 0 to 1000 mg/L Chloride · Remove the cap from the small plastic vessel. Rinse the plastic vessel with water sample, fill to the 5 mL mark and replace the cap. [. . . ] In high levels, chloride can corrode stainless steel and be toxic to plant life. The Hanna Chloride Test Kit is equipped with all you need to determine chloride level of water. The kit is quick, easy to use and portable. The design makes the kit easy to handle and, except for HI 3815 Mercuric Nitrate solution, practically prevents accidental injury or damage due to spills. Note: mg/L is equivalent to ppm (parts per million). x 100 = Cl ­ Note: push and twist pipet tip onto tapered end of syringe ensuring an air-tight fit. To improve the accuracy of the test: use a 5mL pipette for HR or 50mL pipette for LR to deliver the exact volume of sample to the plastic vessel. After use, rinse the calibrated plastic vessel a couple of times with water, or it may become permanently stained. www. hannainst. com SPECIFICATIONS · While swirling the vessel, add the Nitric Acid Solution dropwise until the solution turns yellow. · Take the titration syringe, and push the plunger completely into the syringe. Insert tip into HI 3815-0 Mercuric Nitrate Solution and pull the plunger out until the lower edge of the plunger seal is on the 0 mL mark of the syringe. · Place the syringe into the cap of the plastic vessel and slowly add the titration solution dropwise, swirling to mix after each drop. Continue adding titration solution until the solution in the plastic vessel changes from yellow to violet. Dear Customer, Thank you for choosing a Hanna Product. Please read the instructions carefully before using the chemical test kit. It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. [. . . ] The color change from yellow to purple determines the end point of this titration. HEALTH AND SAFETY The chemicals contained in this test kit may be hazardous if improperly handled. Read Health and Safety Data Sheets before performing the test. ISTR3815R3 07/02 PRINTED IN ITALY · Read off the milliliters of titration solution from the syringe scale and multiply by 1000 to obtain mg/L (ppm) chloride. x 1000 = Cl ­ HI 3815 CHLORIDE TEST KIT 1 DIPHENYLCARBAZONE INDICATOR 2 NITRIC ACID SOLUTION 3 4 until solution turns yellow 5 mL sample 50 mL sample 5 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 3815

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 3815 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag