User manual HANNA INSTRUMENTS HI 8417

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 8417. We hope that this HANNA INSTRUMENTS HI 8417 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 8417.


Mode d'emploi HANNA INSTRUMENTS HI 8417
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 8417

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI8417 - HI8519 HI8520 - HI8521 Microprocessor Bench-top pH Meters HI 84 17 °C pH ON OFF t3 d3 BUFF ER VA d1 LUES NB 20°C t1 STD S pH 6, 8 d2 pH NB 7, 02 8 STD S pH 4, 0 pH NBS 4, 00 0 pH STD 9, 2 pH 10, 05 2 t2 CAL CON °C °C pH mV http://www. hannainst. com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with CSA, UL and (EN 50081-1 and EN 50082-1) directives. TABLE OF CONTENTS PRELIMINARY EXAMINATION GENERAL DESCRIPTION FUNCTIONAL DESCRIPTION AND SPECIFICATIONS: HI8417 HI8519 HI8520 HI8521 OPERATIONAL GUIDE PH CALIBRATION PROCEDURE FOR HI8417 PROCEDURE FOR HI8519 PROCEDURE FOR HI8520/HI8521 CAL. [. . . ] (Note: the "pH" symbol will be flashing throughout the calibration procedure). The buffer value will be CON displayed on the right LCD. · Allow 1-2 minutes for the pH reading to stabilize. The pH reading will be temperature compensated. if the buffer temperature is at 25°C, the right display will show "pH 7. 01". If the buffer temperature is at 20°C, the display will show "pH 7. 03" (see page 23). °C pH If "Err4" appears the calibration solution is wrong. Note: If you are not using the ATC probe, refer to page 22 to manually correct for temperature. · Press the CON key again to accept the buffer value. CON The first point calibration is now complete. · If the pH/mV key is pressed at this point, the calibration process is ended and only the offset of the meter is calibrated. For greatest accuracy, however, it is recommended that a two-point calibration is performed. · Rinse the electrode and the temperature probe before immersing them into pH 4. 01/ pH10. 01 (or 9. 18) calibration buffer, shake briefly and wait for thermal equilibrium. 19 · The meter automatically recognizes the buffer value and prompts for the second at "d2" or "t2" (= pH 4. 01, acid) or "d3" or "t3" (pH 9. 18 and pH10. 01 respectively, alkaline). CON · Press the CON key to confirm the pH value. · The display will indicate the temperature compensated buffer value e. g. if the temperature is at 25°C, the display will show "pH 4. 01" or "10. 01" or "pH 9. 18", depending on the solution being used. If the temperature is at 20°C, the display will show respectively "pH 4. 00" or "pH 10. 06" or "pH 9. 22" (see page 23). °C pH · Press CON key again to confirm calibration. · The pH symbol will stop flashing and the unit is ready for measurements. · If the reading is drifting, turn the meter off and repeat the calibration procedure waiting longer for the reading to stabilize. However, usually 1 or 2 minutes is enough time to prevent a drifting reading. Note: If you need to unplug the instrument, press the OFF key thus switching the instrument off before disconnecting the power cord. In this way the instrument will retain the calibration data. Otherwise, re-calibration might be necessary. In the case of a power failure while the instrument is operational, recalibration might be required. PH CALIBRATION FOR HI8519 Note: If you need to calibrate to NBS standards, use pH 6. 86 (HI7006 or HI8006) and pH 9. 18 (HI7009 or HI8009) instead of pH7. 01 and 10. 01 respectively. [. . . ] Use: general purpose. 12 mm 0. 5" HI 3230 120 mm 4. 7" "S" VERSION HI 4430B Plastic-body (Ultem®), gel-filled, combination gold ORP electrode. Use: general purpose. 12 mm 0. 5" HI 4430 120 mm 4. 7" "S" VERSION Extension cables for screw-type electrodes only (screw to BNC connector): HI7855/1 Extension cable 1m (3. 3') long HI7855/3 Extension cable 3m (9. 9') long HI7855/5 Extension cable 5m (16. 5') long HI 7855 SERIES CABLE CONNECTORS CONNECTOR AND 3. 0 mm (0. 12") CABLE WITH BNC CONNECT TO SCREW TYPE ELECTRODES CONNECT TO THE BNC SOCKET OF THE METER 35 HI7855/10 Extension cable 10m (33') long HI7855/15 Extension cable 15m (49. 5') long Power Units: HI710005 HI710006 Voltage adapter from 115 VAC to 12 VDC Voltage adapter from 230 VAC to 12 VDC OTHER ACCESSORIES ChecktempC Pocket-size thermometer (range -50. 0 to 150. 0°C) HI 76405 Electrode holder HI 7669/2W Temperature probe with 1 m (3. 3') screened cable (not for HI 8519) HI 8427 pH and ORP electrode simulator with 1 m (3. 3') coaxial cable ending in female BNC connectors HI 931001 pH and ORP electrode simulator with LCD and 1 m (3. 3') coaxial cable ending in female BNC connectors MANPHBNR3 Instructions manual 36 ELECTRODE APPLICATION REFERENCE GUIDE Application 1. Aquarium Bath-water Beer Bread Cheese Dairy products Dirty water Emulsions Environment Flasks Food industry general use Fruit Fruit juices, organic Galvanizing waste solution Heavy-duty applications High purity water Horticulture In-line applications Laboratory general use Leather Lemon juice Meat Micro plate sampling of less than 100 mL Milk and Yogurt Paints Paper Photographic chemicals Quality control Sausages Semisolid products Skin Soil samples Solvents Strong acid Submersion application Surface measurements Swimming pool Titrations with constant temperature range Titrations with wide temperature range Very high humidity Vials and test tube Wine processing Electrodes HI 1332B, HI 1911B HI 1910B, HI 1130B HI 1131B HI 2031B, FC 200B FC 200B FC 911B, FC 100B HI 1910B, HI 1912B HI 1053B HI 1230B HI 1331B FC 911B, FC 100B FC 200B, FC 220B FC 210B HI 1130B, HI 1912B HI 1135B HI 1053B HI 1053B, FC 200B HI 1134B, HI 1135B, HI 2114B, HI 2910B HI 1131B, HI 1230B, HI 1332B, HI 1330B HI 1413B FC 100B FC 200B, HI 2031B HI1083B FC 210B HI 1053B HI 1413B HI 1230B HI 1332B FC 200B, HI 2031B HI 2031B HI 1413B HI 1230B HI 1043B HI 1043B HI 1130B HI 1413B H I1130B, HI 2114B, HI 2910B HI 1131B HI 1131B FC 911B, HI 1912B, HI 1911B HI 1330B FC 220B 37 WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrodes and the probes are guaranteed for a period of six months. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 8417

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 8417 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag