User manual HANNA INSTRUMENTS HI 9056

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9056. We hope that this HANNA INSTRUMENTS HI 9056 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 9056.


Mode d'emploi HANNA INSTRUMENTS HI 9056
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 9056

Detailed instructions for use are in the User's Guide.

[. . . ] 7 Display Codes Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Battery Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Shockproof Rubber Boots . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Hanna manufactures several K-type thermocouple probes for different applications. See pages 14-17 for more details. FUNCTIONAL DESCRIPTION AND SPECIFICATIONS FOR HI 9056 1. Measurement Resolution Key (0. 1 or 1) 5. Memory Recalling Key. Specifications Range Resolution Accuracy (@20°C / 68°F) Typical EMC Deviation Probe Battery Environment Dimensions Weight -200. 0 to 1370°C 0. 1°C (-200. 0 to 999. 9°C) 1°C (1000 to 1370°C) ±0. 2% F. S. for one year, excluding probe error ±3°C ±6°F K-thermocouple (optional) (see pages 14-17) 9V/300 hours of continuous use 0 to 50°C (32 to 122°F); 95% RH 180 x 83 x 40 mm (7. 1 x 3. 3 x 1. 6") 350 g (12. 4 oz. ) 4 5 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 9057 OPERATIONAL GUIDE INITIAL PREPARATION Remove the battery cover on the rear of your thermometer, unwrap the battery and connect it to the clip. Insert the battery into the compartment and replace the cover. To switch on, press ON/OFF on the front of the unit. ON OFF 1. Thermocouple Type Selection Key (K or J or T) 5. Measuring Scale key (°C or °F). Specifications -200. 0 to 1370°C / -300. 0 to 2500°F -200. 0 to 900. 0°C / -300. 0 to 1650°F -200. 0 to 400. 0°C / -300. 0 to 750. 0°F Resolution 0. 1°C (up to 999. 9°C) 0. 1°F(up to 999. 9°F) 1°C (over 1000°C) 1°F (over 1000°F) Accuracy K= ±0. 2% F. S. (@20°C / 68°F) J = ±0. 2% F. S. for one year, excluding probe error Typical EMC ±3°C Deviation ±6°F Probe K, J and T thermocouple (optional) (for K-thermocouple see pages 14-17) Battery 9V/300 hours of continuous use Environment 0 to 50°C (32 to 122°F); 95% RH Dimensions 180 x 83 x 40 mm (7. 1 x 3. 3 x 1. 6") Weight 350 g (12. 4 oz. ) Range K J T The thermometer performs a self diagnostic test. The LCD dispalys all the segments at once, to ensure none are missing. BAT HOLD KJT ºC ºF HI LO After the test, the thermometer will switch to the measurement mode. If a temperature probe is plugged in, the unit will display the temperature. If the probe is not plugged in, the display will show "----". To switch your thermometer off, press ON/ OFF again. MEASURING SCALE (°C/°F) (HI 9057 only) When the meter is turned on, it automatically defaults to the °C scale. Measurements can be performed on either the Centigrade or the Fahrenheit scale. 6 7 To change the scale, press °C/°F once. °C °F °F Check the highest or lowest measured temperature by pressing the respective HI or LO key. The appropriate display indicator, "HI" or "LO", will light up together with the value retrieved from memory. °C HI MEASUREMENT RESOLUTION When switched on, HI 9056 °C and HI 9057 default to a 0. 1 digit resolution (see specifications). These instruments automatically change the resolution to 1 degree when the measured temperature is higher than 999. 9°C. In HI 9056, when the temperature is lower than 999. 9°C it is possible to change the resolution by pressing the 0. 1/1 key. HOLD MODE (HI 9057 only) The reading hold function is activated by the HOLD key. To freeze the measured temperature on the display, press and hold the HOLD key. "HOLD" is displayed when this key is pressed. °C LO Release the key to resume normal operation. CLEAR HI-LO FUNCTION (HI 9057 only) By pressing HI and LO simultaneously the present measurement reading is assigned in memory as the highest and lowest temperature reading, i. e. both "HI" and "LO" will have equal temperature readings. HOLD As soon as the HOLD key is released, the meter returns to normal operational mode. HI-LO FUNCTION (HI 9057 only) Maximum and minimum temperatures are monitored throughout a continuous measuring process. [. . . ] You can turn it off by pressing ON/OFF. SHOCKPROOF RUBBER BOOTS These rubber boots are specially made to prolong the life of your instruments and to prevent damage due to accidental falls. They and are available in two different colors: HI 710009 = blue colored HI 710010 = orange colored Select the proper color according to your preference. 12 13 ACCESSORIES HI 766PE1 General use probe, max 900°C/1650°F K-Type Thermocouple Probes with detachable handle & mini-connector (to be plugged into HI 766HD probe handle): HI 766PA Roller surface probe, max 320°C/600°F 155mm 6. 1" 3mm 0. 12" HI 766PE2 General use probe, max 900°C/1650°F 100mm 4" 280mm 11" 7. 8" HI 766PB Surface probe, max 650°C/1200°F 200mm 7. 8" 5mm 0. 20" HI 766HD Rugged thermocouple probe handle with 1 m (3. 3' ) cable fitted with a miniconnector 200mm 7. 9" with integral handle, 1 m cable & miniconnector: HI 766PC Penetration probe, max 900°C/1650°F 155mm 6. 1" HI 766A Roller surface probe, max 320°C/600°F 100mm 4" 280mm 11" 3mm 0. 12" HI 766PD Air probe, max 300°C/570°F 420mm 13. 3" 16. 5" 250mm 9. 8" 3mm 0. 12" HI 766B Surface probe, max 650°C/1200°F 400mm 15. 7" 260mm 10. 2" 14 15 HI 766B1 90° surface probe, max 450°C/840°F HI 766E2 General use probe, max 900°C/1650°F 360mm 13. 8" 220mm 8. 5" 5mm 0. 2" 30mm 1. 2" 300mm 11. 8" HI 766B2 Surface probe, max 900°C/1650°F 8mm 0. 3" 130mm 5. 1" HI 766F High temperature wire probe without handle, max 1100°C/2000°F 255mm 10" 1. 5mm 0. 06" HI 766B3 Small surface probe with insulated shaft, max 200°C/390°F 5mm 0. 2" 130mm 5. 1" HI 766F1 Flexible probe without handle, max 480°C/900°F 2mm 0. 08" 1m 3. 3' HI 766C Penetration probe, max 900°C/1650°F 260mm 10. 3" 120mm 4. 8" 3mm 0. 12" HI 766TV1 Pipe clamp probe, max 200°C/390°F HI 766D Air probe, max 300°C/570°F 385mm 15. 2" 245mm 9. 6" 3mm 0. 12" 35mm Max. 1. 4" HI 766E1 General use probe, max 900°C/1650°F 260mm 10. 2" 120mm 4. 7" 3mm 0. 12" Other accessories: HI 710002 Soft carrying case HI 710009 Blue rubber boot HI 710010 Orange rubber boot 17 16 WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrodes and the probes are guaranteed for a period of six months. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9056

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9056 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag