If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 931300. We hope that this HANNA INSTRUMENTS HI 931300 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 931300.


Mode d'emploi HANNA INSTRUMENTS HI 931300
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 931300

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI931300 HI 931301 Portable Microprocessor Logging pH Meters with Last Calibration Data Storage RANGE pH 0. 00 . +100. 0 These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a more precise idea of its versatility in a wide range of applications. [. . . ] Place the probe as close as possible to the reference thermometer. The secondary display (lower) LCD will blink "0" for approximately 30 seconds. °C 0 °C (32 °F) CAL 20 · When "0" stops blinking, the calibration can be confirmed. Press the CFM key to confirm the first temperature value. CFM · If the value is out of the offset range, "E1" as error message will show on the secondary display. Press the CAL key to re-calibrate the value. CAL · If everything is satisfactory the secondary LCD will blink "50" expecting the second temperature measurement. Note: If a single point calibration is required, press the CAL key to leave the temperature calibration mode now. However, it is always better to proceed as follows for a two-point calibration. · Immerse the temperature probe in the container at 50°C (122°F). Place the probe as close as possible to the reference thermometer. CAL °C 50 °C (122 °F) · When "50" stops blinking, indicating that the probe has stabilized, press the CFM 21 key again to confirm the second calibration point. CFM · If the input is out of the slope range, "E2" as error message will appear on the secondary display. Press the CAL key to recalibrate the value. CAL If everything is satisfactory the temperature calibration is complete and the meter will resume the normal operational mode. 22 LOGGING FUNCTION (HI931300 only) LOGGING MODE In this mode data will be stored directly into memory for later retrival. Set the appropriate logging interval (see Operational Guide section on page 6). Press the ALT and the LOG keys simultaneously to enter the logging mode. The log number and page number will appear for a few seconds on the display to indicate the correct operational mode. ON/OFF LOG ALT CAL When the meter is in logging mode, "LOG" is displayed on the bottom left corner of the LCD with the time on the primary display and the logging interval on the secondary one. During logging, press the LOG key to show the total number of data that has been logged (sample number). TIME LOG INTV LOG To view measurements during logging press the RANGE key and the display will show the temperature. °C RANGE 23 To view the pH values press the RANGE key again. pH RANGE To return to the logging information press the LOG key. LOG After approximately 5 minutes the display will switch off but the logging function remains active. To reactivate the display press the ON/OFF key. ON/OFF Note: Once in the logging mode, the interval cannot be changed. Exit the logging mode first (pressing the ALT and the LOG keys) before setting the new interval. ON/OFF LOG ALT CAL TO STOP LOGGING To stop logging, press the ALT and LOG keys simultaneously. The display will show the lot and page number again for a few seconds. ON/OFF LOG ALT CAL The running lot number can be reset by simply removing and replacing the batteries. 24 DATA TRANSFER TO PC HI 931300 contains infrared emitting circuitry. Set the meter to the TIME mode and simply place your data-logger on a HI9200 Infrared Transmitter (ensuring that TIME the two infrared LEDs are placed on top of each other) and the memory can then be downloaded to your PC through the HI9200's RS232 port. During the data transfer the instrument displays the message "r 232". Using the HI9200 Infrared Transmitter, all recorded data can be fed to your Personal Computer for easy reproduction, storage or elaboration without the interference of cables or cords between the meter and the transmitter. Data transmission from the instrument to the PC is now much easier with new HI92000 Windows® compatible application software offered by Hanna Instruments. Windows® is registered Trademark of "Microsoft Co. " 25 HI92000 allows you to use the powerful means of most spread sheet programs (e. g. Simply open the file downloaded by HI92000 and it is possible to make any elaboration available with your software (e. g. User friendly, HI92000 offers a variety of features and has an on line help to support you throughout any situation. To install HI92000 you need a 3. 5" drive and a few minutes to follow the instructions conveniently printed on the disk label. FAULT FUNCTIONS Erroneous solution used for the offset calibration For pH calibration: Make sure the buffer solution used is pH 7 and replace if necessary For temperature calibration: Make sure the water is at 0°C/32°F Erroneous solution used for the offset calibration For pH calibration: Make sure the buffer solution used is pH 4 or 10. [. . . ] Use: surface measurement. 12 mm 0. 5" HI 1413 110 mm 4. 3" Kynar® is registered Trademark of "Pennwalt Corp. " 40 Extension cables for screw-type electrodes only (screw to BNC connector) HI7855/1 HI7855/3 HI7855/5 HI7855/10 HI7855/15 Extension cable 1m (3. 3') long Extension cable 3m (9. 9') long Extension cable 5m (16. 5') long Extension cable 10m (33') long Extension cable 15m (49. 5') long HI 7855 SERIES CABLE CONNECTORS CONNECTOR AND 3. 0 mm (0. 12") CABLE WITH BNC CONNECT TO SCREW TYPE ELECTRODES CONNECT TO THE BNC SOCKET OF THE METER POWER UNITS HI710005 HI710006 Voltage adapter from 110 VAC to 12 VDC Voltage adapter from 220 VAC to 12 VDC 41 OTHER ACCESSORIES BAT1. 5AA/P 1. 5V AA battery (8 pcs) ChecktempC Pocket-size thermometer with penetration probe and 0. 1°C resolution (range -50. 0 to 150. 0°C) HI 76405 Electrode holder HI 7669/2W HI 8427 Temperature probe with 1 m (3. 3') screened cable pH and ORP electrode simulator with 1 m (3. 3') coaxial cable ending in female BNC connectors (HI 7858/1) Infrared Transmitter Windows® software for data transfer to PC pH and ORP electrode simulator with LCD display 1 m (3. 3') coaxial cable ending in female BNC connectors (HI 7858/1) Instruction manual Rugged carrying case HI 9200 HI 92000 HI 931001 MAN9313R1 HI710031 Windows® is registered Trademark of "Microsoft Co. " 42 ELECTRODE APPLICATION REFERENCE GUIDE Application 1. Laboratory general use Electrodes HI 1332B, HI 1911B, HI 1312S HI 1910B, HI 1130B, HI 1110S HI 1131B, HI 1111S HI 2031B, FC 200B, HI 2020S, FC 200S FC 200B, FC 200S FC 911B, FC 100B HI 1910B, HI 1912B HI 1053B, HI 1050S HI 1230B, HI 1210S HI 1331B, HI 1310S FC 911B, FC 100B FC 200B, FC 220B, FC 200S FC 210B HI 1130B, HI 1912B, HI 1110S HI 1135B, HI 1115S HI 1053B, HI 1050S HI 1053B, FC 200B, HI 1050S, FC 200S HI 1134B, HI 1135B, HI 2114B, HI 2910B, HI 1114S, HI 1115S HI 1131B, HI 1230B, HI 1332B, HI 1330B HI 1111S, HI 1210S, HI 1312S, HI 1310S HI 1413B, HI 1410S FC 100B FC 200B, HI 2031B, FC 200S, HI 2020S HI 1083B, HI 1080S FC 210B HI 1053B, HI 1050S HI 1413B, HI 1410S HI 1230B, HI 1210S HI 1332B, HI 1312S FC 200B, HI 2031B, FC 200S, HI 2020S HI 2031B, HI 2020S HI 1413B, HI 1410S HI 1230B, HI 1210S HI 1043B, HI 1040S HI 1043B, HI 1040S HI 1130B, HI 1110S HI 1413B, HI 1410S H 1130B, HI 2114B, HI 2910B HI 1131B, HI 1111S HI 1131B, HI 1111S FC 911B, HI 1912B, HI 1911B HI 1330B, HI 1310S FC 220B 20. Micro plate sampling of less than 100 mL 24. Titrations with constant temperature range 39. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 931300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 931300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag