User manual HANNA INSTRUMENTS HI 933000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 933000. We hope that this HANNA INSTRUMENTS HI 933000 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 933000.


Mode d'emploi HANNA INSTRUMENTS HI 933000
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 933000 (553 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 933000

Detailed instructions for use are in the User's Guide.

[. . . ] Untitled-19 1 2 Instruction Manual HI 8033 - HI 8633 HI 8733 - HI 8734 HI 933000 Portable Multi-Range Conductivity/TDS Meters mS Dear Customer, Thank you for choosing a Hanna Product. Please read this instruction manual carefully before using the instrument. It will provide you with the necessary information for a correct use of the instrument, as well as a more precise idea of its versatility. These instruments are in compliance with the directives EN 50081-1 and EN 50082-1. TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] the conductivity reading @ 25°C. mS mS · All subsequent measurements will be compensated to 25°C (77°F). If you prefer to standardize the temperature compensation to 20°C (68°F) rather than 25°C (77°F), adjust the trimmer to read "11. 67 mS" (see the conductivity vs. All subsequent measurements will be compensated to 20°C. · The calibration is now complete and the instrument is ready for use. 13 14 HI 7 03 COND. PROCEDURE FOR HI 8733 0 Untitled-19 15 16 The instrument should be re-calibrated at least once a month, or when the probe or battery is changed. Note: For more accurate results, it is advisable to use a calibration solution close to the range to be measured. See the accessories section on page 23 for a wide selection of conductivity solutions. · Pour sufficient quantity of a TDS calibration solution (e. g. HI 7032) into a beaker to cover the holes on the probe. If possible, use plastic beakers to minimize any EMC interference. · Immerse the TDS probe, making sure that holes are completely submerged, and the ChecktempC in the solution. · Wait for a couple of minutes for thermal equilibrium to be reached. · Tap the probe on the bottom, then shake it while rotating to make sure no air bubbles remain trapped in the sleeve. · Record the temperature of the HI 7032 buffer solution from the ChecktempC (e. g. 18°C). HI °C · Adjust the calibration trimmer (see page 7, #6) on the side of the instrument with the calibration screwdriver until the display shows the TDS reading at 25°C (see the TDS vs. @25°C "1382 mg/L". 703 PROCEDURE FOR HI 8734 0 TEMPERAT URE · Switch the instrument on by pressing ON/OFF. · Press TDS/TEMP to display the temperature. · Adjust the TEMPERATURE knob to display 18°C. ON OFF · All subsequent measurements will be compensated to 25°C (77°F). If you prefer to standardize the temperature compensation to 20°C (68°F) rather than 25°C (77°F), leave the TEMPERATURE knob to 18°C (if the temperature of the solution is 18°C). Adjust the trimmer to read "1251 mg/L" (see the TDS vs. All subsequent measurements will be compensated to 20°C. · The calibration is now complete and the instrument is ready for use. [. . . ] Make sure the battery contacts are tight and secure before replacing the cover. HI 933000 9 VOLT BATTERY HI 8033 HI 8633 HI 8733 HI 8734 SLIDE OFF BATTERY SLIDE OFF 21 22 Untitled-19 23 24 SHOCKPROOF RUBBER BOOTS only) ( for H I 933000 only ) These rubber boots are specially made to prolong the life of your instrument and to prevent damage due to accidental bangs and falls. They measure 155 x 90 x 45 mm (6. 1x3. 5x1. 8") and are available in two different colors: HI 710007 = blue HI 710008 = orange. CONDUCTIVITY BUFFER SOLUTIONS IN FDA APPROVED BOTTLES HI 8030L HI 8031L HI 8033L HI 8034L HI 8035L HI 8039L 12880 µS/cm (µmho/cm), 460 mL 1413 µS/cm (µmho/cm), 460 mL 84 µS/cm (µmho/cm), 460 mL 80000 µS/cm (µmho/cm), 460 mL 111800 µS/cm (µmho/cm), 460 mL 5000 µS/cm (µmho/cm), 460 mL mS CONDUCTIVITY METER ON OFF CONDUCTIVITY PROBES HI 76301W 4-ring conductivity/TDS probe with 1 m (3. 3') screened cable (for HI 8033, HI 8633 and HI 8734) 19, 5mm DIA 0. 77" 199. 9 µS 1999 µS 19. 99 mS 199. 9 mS HI933000 85mm 3. 34" 11. 5mm DIA 0. 45" 118. 5mm 4. 66" ACCESSORIES CONDUCTIVITY & TDS BUFFER SOLUTIONS HI 7030L HI 7030M HI 7031L HI 7031M HI 7033L HI 7033M HI 7034L HI 7034M HI 7035L HI 7035M HI 7039L HI 7039M HI 7032L HI 7032M HI 7036L HI 7036M 12880 µS/cm (µmho/cm), 460mL 12880 µS/cm (µmho/cm), 230mL 1413 µS/cm (µmho/cm), 460mL 1413 µS/cm (µmho/cm), 230mL 84 µS/cm (µmho/cm), 460 mL 84 µS/cm (µmho/cm), 230 mL 80000 µS/cm (µmho/cm), 460mL 80000 µS/cm (µmho/cm), 230mL 111800 µS/cm (µmho/cm), 460mL 111800 µS/cm (µmho/cm), 230mL 5000 µS/cm (µmho/cm), 460mL 5000 µS/cm (µmho/cm), 230mL 1382 ppm (mg/L), 460 mL 1382 ppm (mg/L), , 230 mL 12. 41 ppt (g/L), 460 mL 12. 41 ppt (g/L), 230 mL HI 76302W 4-ring conductivity probe with built-in temperature sensor and 1 m (3. 3') screened cable (for HI 933000) HI 7633W 4-ring conductivity probe with built-in temperature sensor and 1 m (3. 3') screened cable (for HI 8733) 19, 5mm DIA 0. 77" 85mm 3. 34" 11. 5mm DIA 0. 45" 118. 5mm 4. 66" OTHER ACCESSORIES HI 710001 Soft carrying case for HI 8033, HI 8633, HI 8733, HI 8734 and HI 933000 measuring 230x100x50 mm CHECKTEMPC Electronic thermometer (range: -50. 0 to 150. 0°C) HI 721313 Rugged carrying case for HI 8733 and HI 8633 measuring 340 x 230 x 90 mm complete with conductivity calibration solution (HI 7030S, 120 mL) and screwdriver 24 23 Untitled-19 25 26 HI 721314 Rugged carrying case for HI 8734 measuring 340x230x90 mm complete with TDS calibration solution (HI 7032S, 120 mL) and screwdriver HI 731326 20 small screwdrivers, length 90 mm, for calibration purposes (except for HI 8033) HI 710007 Blue shockproof rubber boot for HI 933000 HI 710008 Orange shockproof rubber boot for HI 933000 HI 710009 Blue rubber boot for HI 8033, HI 8633, HI 8733 and HI 8734 HI 710010 Orange rubber boot for HI 8033, HI 8633, HI 8733 and HI 8734 MANCONDR2 Instruction manual CE DECLARATION OF CONFORMITY WARRANTY All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrodes and the probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 933000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 933000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag