User manual HANNA INSTRUMENTS HI 935006

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 935006. We hope that this HANNA INSTRUMENTS HI 935006 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 935006.


Mode d'emploi HANNA INSTRUMENTS HI 935006
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 935006

Detailed instructions for use are in the User's Guide.

[. . . ] 8 Functional Description and Specifications of HI 935005 . . . . . . . . . . . . . . . . . . . . . . 9 Functional Description and Specifications of HI 935006 . . . . . . . . . . . . . . . . . . . . 10 Functional Description and Specifications of HI 935007 . . . . . . . . . . . . . . . . . . . . 11 Operational Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Measurement Resolution Key (0. 1 or 1) 5. Memory Recalling Key. Specifications Range Resolution Accuracy Typical EMC Deviation Probe Battery Environment Dimensions Weight -200. 0 to 1370°C 0. 1°C (-200. 0 to 999. 9°C) 1°C (1000 to 1370°C) ±0. 2% F. S. for one year, excluding probe error ±3°C ±6°F K-thermocouple (optional) (see pages 22-25) 9V/100 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) 1. Thermocouple Type Selection Key (K or J or T) 5. Measuring Scale key (°C or °F). Specifications Range K J T -200. 0 to 1370°C / -300. 0 to 2500°F -200. 0 to 900. 0°C / -300. 0 to 1650°F -200. 0 to 400. 0°C / -300. 0 to 750. 0°F 0. 1°C (up to 999. 9°C) 0. 1°F(up to 999. 9°F) 1°C (over 1000°C) 1°F (over 1000°F) K= ±0. 2% F. S. for one year, excluding probe error ±3°C ±6°F K, J and T thermocouple(optional) (for K-thermocouple see pages 22-25) 9V/100 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) Resolution Accuracy Typical EMC Deviation Probe Battery Environment Dimensions Weight 7 8 mank93r4. p65 9 10 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 935005 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 935006 ins rum n s °C ins rum n s 1 °C 1 RANGE: -80. 0°C to +400°C K-THERMOCOUPLE THERMOMETER 7 CLEAR ON OFF 2 ON OFF 2 6 HI HOLD 3 5 HI 935005 LO °C °F 4 Foodcare RANGE: -50°C to +950°C HI 935006 1. Measuring Scale Key (°C or °F) 5. HI/LO Temperature erasing key. Specifications Low Range High Range Resolution -50. 0 to 150. 0°C -58. 0 to 199. 9°F / 200 to 302ºF -50 to 950°C -58 to 1742°F 0. 1°C (-50. 0 to 150. 0°C) 1°C (-50 to 950°C) 0. 2°F (-58. 0 to 199. 9°F) 1°F (-58 to 1742°F) ±0. 4ºC (low range ºC) ±0. 8ºF (low range ºF) ±0. 2% f. s. (high range ºC/ºF) ±3°C ±6°F K-thermocouple (pag. 22-25) 9V/500 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) 1. ON/OFF Key. Specifications Range Resolution Accuracy Typical EMC Deviation Probe Battery Environment Dimensions Weight -80. 0 to 120. 0°C 121 to 400°C 0. 1°C (-50. 0 to 120. 0°C) 1°C (120 to 400°C) ±0. 3% for one year, excluding probe error ±3°C T-thermocouple (optional) 9V/500 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) Accuracy Typical EMC Dev. Probe (optional) Battery Environment Dimensions Weight 9 10 mank93r4. p65 11 12 FUNCTIONAL DESCRIPTION AND SPECIFICATIONS OF HI 935007 OPERATIONAL GUIDE INITIAL PREPARATION Remove the battery cover on the rear of your thermometer, unwrap the battery and connect it to the clip. Insert the battery in its compartment and replace the cover. 9 VOLT BATTERY Battery Compartment SLIDE OFF To switch on, press ON/OFF on the front of the unit. ON OFF 1. Measuring Scale Key (°C or °F). Specifications Low Range High Range Resolution -50. 0 to 150. 0°C -58. 0 to 199. 9°F / 200 to 302ºF -50 to 950°C -58 to 1742°F 0. 1°C (-50. 0 to 150. 0°C) 1°C (-50 to 950°C) 0. 2°F (-58. 0 to 199. 9°F) 1°F (-58 to 1742°F) ±0. 4ºC (low range ºC) ±0. 8ºF (low range ºF) ±0. 2% f. s. (high range ºC/ºF) ±3°C ±6°F HI766C K-thermocouple 9V/500 hrs of continuous use 0 to 50°C (32 to 122°F); 95% RH 143x80x38mm (5. 6x3. 2x1. 5") 320 g (11. 3 oz. ) Your thermometer will carry out a self diagnostic test. The LCD shows all the segments at once, to make sure none is missing. BAT HOLD KJT ºC ºF HI LO After the test, the thermometer will switch to the measurement mode. If a temperature probe is plugged in, the unit will display the temperature. For HI 93530, HI93531, HI 93532, HI 93551 If the probe is not plugged in, the display will show "----". For HI 935005 and HI 935006 If the probe is not plugged in, the display will show "Er". To switch your thermometer off, press ON/OFF again. Accuracy Typical EMC Dev. Probe (included) Battery Environment Dimensions Weight ON OFF 11 12 mank93r4. p65 13 14 MEASURING SCALE (°C/°F)(for HI93530, HI93531, HI93551, HI935005, HI935007 only) When the meter is turned on, it automatically defaults to the °C scale. Measurements can be performed on either the Centigrade or the Fahrenheit scale. To change the scale, press °C/°F once. HOLD MODE (for HI93530, HI93551 and HI 935005 only) The reading hold function is activated by the HOLD key. [. . . ] To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. HI 766F High temperature wire probe without handle, max 1100°C/2000°F 255mm 10" 1. 5mm 0. 06" HI 766F1 Flexible probe without handle, max 480°C/900°F 2mm 0. 08" 1m 3. 3' HI 766TV1 Pipe clamp probe, max 200°C/390°F 35mm Max. 1. 4" Other accessories: HI 710004 Soft carrying case measuring 150x90x30mm HI 710007 Blue rubber boot measuring 155 x 90 x 45 mm HI 710008 Orange rubber boot measuring 155 x 90 x 45 mm HI 710031 Rugged carrying case MANK93R4 Instruction manual 25 All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 26 mank93r4. p65 27 28 CE DECLARATION OF CONFORMITY MANK93R4 02/01 Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 935006

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 935006 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag