If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 93727. We hope that this HANNA INSTRUMENTS HI 93727 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 93727.
Manual abstract: user guide HANNA INSTRUMENTS HI 93727
Detailed instructions for use are in the User's Guide.
[. . . ] A flashing value higher than the maximum concentration readable (see specifications) indicates that the sample absorbs too much light, meaning that the concentration is too high. The cuvet is not inserted correctly and an excess ambient light is reaching the detector. If the cover is properly installed, then contact your dealer or the nearest Hanna Customer Service Center. [. . . ] If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. , Woonsocket, Rhode Island, 02895 , USA. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
The HI 93727 meter measures the true and apparent color in water and wastewater in the 0 to 500 PCU (Platinum Cobalt Units) range. The meter uses an exclusive positive-locking system to ensure that the cuvet is in the same place every time it is placed into the measurement cell. Display codes aid the user in routine operations. The meters have an auto-shut off feature that will turn the instrument off after 10 minutes of non-use.
Light Emitting Diode @ 470 nm Adaptation of the Colorimetric Platinum Cobalt method Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type/Life 1 x 9 volt/40 hours Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ).
REQUIRED ACCESSORIES
0. 45 µm membrane for true color measurement.
V
OPERATIONAL GUIDE
MEASUREMENT PROCEDURE
· Turn the meter on by pressing ON/OFF. · When the LCD displays "- - -", it is ready. · Fill one cuvet up to 1. 5 cm (¾") below the rim with deionized water and replace the cap. · Fill another cuvet up to 1. 5 cm (¾") below the rim with unfiltered sample and replace the cap. This is the apparent color.
1. 5 cm
ON OFF
· Remove the blank, insert the apparent color cuvet into the instrument and ensure that the notch on the cap is positioned securely into the groove. · Press READ and "SIP" will appear on the display.
TIPS FOR AN ACCURATE MEASUREMENT
The instruction listed below should be carefully followed during testing to ensure best accuracy. · Do not touch the cuvet walls with hands. · In order to maintain the same conditions during the zeroing and the measuring phases, it is necessary to close the cuvet to prevent any contamination. · Do not let the test sample stand too long after reagent is added or accuracy will be lost. [. . . ] · Place the blank into the holder and ensure that the notch on the cap is positioned securely into the groove.
1. 5 cm
· The meter directly displays concentration in color units of true color on the Liquid Crystal Display.
INTERFERENCES
There are no known interferences for this method.
· Press ZERO and "SIP" will appear on the display.
ZERO
BATTERY REPLACEMENT
Battery replacement must only take place in a non-hazardous area using a 9V alkaline battery. Simply slide off the battery cover on the back of the meter. Detach the battery from the terminals and attach a fresh 9V battery while paying attention to the correct polarity. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 93727
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.