User manual HANNA INSTRUMENTS HI 98107

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98107. We hope that this HANNA INSTRUMENTS HI 98107 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 98107.


Mode d'emploi HANNA INSTRUMENTS HI 98107
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98107 (101 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98107

Detailed instructions for use are in the User's Guide.

[. . . ] pHep® HI 98107 Pocket-sized pH Meter pHep is a rugged pH tester with replaceable electrode and renewable reference junction. The instrument can be calibrated at two points by the user, simply acting on the offset and slope calibration trimmers. · To activate the electrode, immerse it in HI70300 storage solution for 2 hours. [. . . ] · Immerse it in the solution to be tested without exceeding the maximum immersion level. · Stir gently and wait for the reading to stabilize. · After use, rinse the electrode with tap water to minimize contamination. · Store the electrode with a few drops of storage (HI70300) or pH7 (HI7007) solution in the protective cap. · Always replace the protective cap after use. DO NOT USE DISTILLED OR DEIONIZED WATER FOR STORAGE PURPOSES. · Large differences in pH readings (±1 pH) could be due to lack of calibration or dry electrode. MAINTENANCE: The sensor should be kept moist at all times. For this purpose, always keep wet the tissue inside the protective cap. In case of erroneous readings even after an accurate conditioning and calibration, the reference junction might be contaminated or clogged. Pull out 2 mm (1/8'') of the cloth junction to renew the electrode reference (it is recommended to cut the cloth leaving always at least 2 mm -1/8'' over the reference compartment) and repeat the calibration procedure. The cloth junction can be pulled out approximately 20 times. After that, the electrode can be replaced (see the Electrode Replacement section). BATTERY REPLACEMENT: If calibration can not be performed or the display fades, batteries level is low and batteries must be replaced. Slide off the battery compartment cover and replace all four 1. 5V batteries while paying attention to their polarity. 300 HI 70 Batteries should only be replaced in a nonhazardous area using the battery type specified in this instruction manual. Manufacturers since 1978 pHep® HI 98107 Pocket-sized pH Meter SPECIFICATIONS: RANGE 0. 0 to 14. 0 pH RESOLUTION 0. 1 pH ACCURACY (@20°C/68°F) ±0. 1 pH TYPICAL EMC DEVIATION ±0. 1 pH ENVIRONMENT 0 to 50 C (32 to 122 F); 95% RH Manual, at two points through CALIBRATION offset and slope trimmers BATTERY TYPE 4 x 1. 5V alkaline (included) BATTERY LIFE approx. 1700 hours of continuous use DIMENSIONS 175 x 41 x 23 mm (7. 9 x 1. 8 x 1") WEIGHT 78 g (2. 7 oz. ) ACCESSORIES: HI 73106 Spare electrode HI 77400P pH 4. 01 & 7. 01 calibration kit (5 x 20 mL, each) HI 77700P pH 7. 01 calibration kit (10 x 20 mL) HI 770710P pH 7. 01 & 10. 01 calibration kit (5 x 20 mL, each) HI 7004M pH 4. 01 buffer solution (230 mL bottle) HI 7007M pH 7. 01 buffer solution (230 mL bottle) HI 7010M pH 10. 01 buffer solution (230 mL bottle) HI 70300M Storage solution (230mL) HI 7061M Electrode cleaning solution (230mL bottle) HI 731326 Calibration screwdriver (20 pcs) Visit our Internet Home Page: http://www. hannainst. com ELECTRODE REPLACEMENT: The electrode can be easily replaced in the following way: · Slide off the battery cover. · Remove the screw on the back of the pHep located below the battery compartment and slide off the whole internal part of the tester. Internal circuit and electrode: · Reinsert the battery compartment cover. [. . . ] · Reinsert the internal circuit with the new electrode into the plastic casing. · Fasten the screw on the back below the battery compartment. · Perform a new calibration before using the pHep again. ONE YEAR WARRANTY & SERVICEABLE: Covered by one year warranty against defects in workmanship and materials, this tester is now completely serviceable. Contact your dealer for further information. The pHep is in compliance with the CE directives EN 50082-1, EN 50081-1 and EN 61010-1. IS98107-R3 09/01 pHep® is a registered Trademark of "Hanna Instruments" [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98107

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98107 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag