User manual HANNA INSTRUMENTS HI 98140

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98140. We hope that this HANNA INSTRUMENTS HI 98140 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 98140.


Mode d'emploi HANNA INSTRUMENTS HI 98140
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 98140 (1305 ko)
   HANNA INSTRUMENTS HI 98140 MANUAL 2 (995 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 98140

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 98140 - HI 98150 Portable Waterproof Microprocessor Logging GLP pH / ORP Meters www. hannainst. com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with the TABLE OF CONTENTS PRELIMINARY EXAMINATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The meter will display "1900 mV" on the lower LCD with the "BUF 3" indication. When the "CFM" symbol blinks, the reading is stable. Press ALT and CFM to confirm the third value. Calibration is now complete, the instrument returns to normal operational mode. Note: "WRONG" message notifies the user if the selected value is wrong. TEMPERATURE CALIBRATION PROCEDURE (for technical personnel only) A two point calibration at 0. 0, 50. 0°C has to be performed in order to store the new calibration data in memory. Immerse the pH electrode with the built-in temperature sensor in the 0°C temperature bath. Press ALT and CALT to enter temperature calibration mode. The meter will display "0. 0 °C" on the lower LCD with the "BUF 1" and "CAL" indication. When the reading is stable the "CFM" symbol starts to blink. LCD will then display 50. 0°C on the lower LCD with the "BUF 2" indication. Immerse the pH electrode with the built-in temperature sensor in the 50°C temperature bath. When the reading is stable the "CFM" symbol starts to blink. Press ALT and CFM to confirm and return to normal operational mode. 16 LOGGING FUNCTION To store the current reading in memory press the LOG key while in measurement mode. The LCD will display "Stor" along with the "LOG" indication and the sample number for a few seconds. By pressing the LOG key a complete set of information is memorized: date, time, pH and mV (HI98150 only) readings, temperature reading and also a message on the meter status. Up to 500 samples can be stored into memory. When the memory is full and the LOG key is pressed, the sample will not be stored and the LCD will display "FULL". In this case it is necessary to delete all the memory to proceed. TO VIEW LOGGED DATA To retrieve the memorized information press ALT and RCL. The meter displays the date (upper LCD) and the number (lower LCD) of the last logged sample. The "ZERO" indication will be displayed if no samples are stored in memory. · Select the desired sample number with the arrow keys. Pressing the key while the last sample is displayed causes the meter to go to the first sample. · Press RANGE to view remaining data of the selected sample. After the date information, the remaining data will be displayed in the following order: 17 - year - time - pH reading "----" means reading out of range or no probe was connected. "OrP" means that an ORP electrode was connected. [. . . ] combination pH electrode, double junction, with built-in temperature NTC sensor and EEPROM for GLP data storing. combination pH electrode with knife (penetration 20mm/ 0. 79"), single junction, with built-in temperature NTC sensor and EEPROM for GLP data storing. combination pH electrode with knife (penetration 35mm/ 1. 38"), single junction, with built-in temperature NTC sensor and EEPROM for GLP data storing. Voltage adapter from 115 VAC to 12 VDC Voltage adapter from 230 VAC to 12 VDC Rugged carrying case 1. 5V AA batteries (4 pcs) Electrode holder pH and mV simulator pH and mV simulator with LCD display 5 to 9-pin cable for connection to PC SMART ELECTRODES HI1616D HI1617D HI1618D HI3619D HI3620D FC 201D FC 212D FC231D FC241D OTHER ACCESSORIES HI710005 HI710006 HI 710031 HI 740027 HI 76405 HI 8427 HI 931001 HI 920011 29 WARRANTY All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98140

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 98140 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag