If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98306. We hope that this HANNA INSTRUMENTS HI 98306 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 98306.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 98306 (148 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 98306
Detailed instructions for use are in the User's Guide.
[. . . ] Conmet 2 Conductivity Meter with ATC*
Specifications: - Range 0. 00 to 19. 99 mS/cm - Resolution 0. 01 mS/cm - Accuracy (@20°C / 68°F) ± 2% of Full Scale - Typical EMC Deviation ± 2% of Full Scale - Temp. Compensation Automatic 0°C to 50°C (32 to 122°F) - ATC Coefficient 1. 9% ±0. 15% per °C, referenced to 25°C (77°F) - Battery type 4 x 1. 5V ALKALINE - Battery life Approximately 150 hours - Operating temperature 0 to 50°C (32 to 122°F); 95% RH max. [. . . ] This avoids the possibility of crosscontamination errors. · When not in use, switch the CONMET 2 off. · To improve performance, clean the probe regularly by rinsing in alcohol for a few minutes. · Replace all 4x1. 5V batteries if the display becomes faint or disappears, or if the reading is unstable or unchanged. · To replace the batteries, switch the CONMET 2 off. Pull out the battery compartment and replace the batteries (Fig. Battery replacement must only take place in a non hazardous area using the battery type specified in this instruction manual.
This meter is in compliance with the CE directives.
*Automatic Temperature Compensation
Since the conductivity concentration changes as the temperature of the sample changes, ATC standardizes the value you read to 25°C (77°F). This feature eliminates the need to measure the temperature and calculate its effects on the conductivity concentration of the sample each time you perform a measurement. The results will be measurements that are consistent with the temperature variable eliminated. Calibration Instructions: · If readjustment is required, connect the conductivity probe to the meter without covering the calibration slot (Fig. · To readjust the CONMET 2, dip it into the calibration solution HI 7030 (12. 88 mS/cm @25°C/77°F). Wait 30 to 45 seconds for the reading to stabilize and, if necessary, correct the reading to "12. 88 " by slowly turning the calibration trimmer with the small screwdriver provided. Return the conductivity probe to its working position when finished. The CONMET 2 Conductivity Meter is supplied in a rugged plastic carrying case with a 120 mL HI 7030 calibration solution bottle (Fig. [. . . ] To avoid damages or burns, do not perform any measurement in microwave ovens. The instrument has to be switched off before cleaning the conductivity probe.
ISCONMET2 03/96 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98306
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.