If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 98311. We hope that this HANNA INSTRUMENTS HI 98311 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 98311.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 98311 (226 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 98311
Detailed instructions for use are in the User's Guide.
[. . . ] Battery compartment Liquid Crystal Display (LCD) ON/OFF/MODE button HI 73311 EC/TDS probe Temperature sensor
HI 98312:
HI7030 (12. 88 mS/cm) HI70038 (6. 44 ppt; CONV=0. 5 or 9. 02 ppt; CONV=0. 7)
Probe (included) Battery Type/Life Auto-off Dimensions Weight
HI 73311 EC/TDS probe 4 x 1. 5V with BEPS/typical 100 hours After 8 minutes 163 x 40 x 26 mm (6. 4 x 1. 6 x 1. 0") 85 g (3. 0 oz)
WARRANTY
HI 98311 and HI 98312 are warranted for one year against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The probe is warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. [. . . ] The stainless steel encapsulated temperature sensor facilitates faster and more accurate temperature measurement and compensation.
SET/HOLD button
1. Automatic temperature compensation indicator 2. Measuring units for primary display
Recommendations for Users Before using this product, make sure that it is entirely suitable for the environment in which it is used. Operation of this instrument in residential areas could cause unacceptable interferences to radio and TV equipment. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use this instrument when voltages at the measurement surface exceed 24 VAC or 60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens.
ISTR98311R2 03/03
OPERATIONAL GUIDE
To turn the meter on and to check battery status Press and hold the /MODE button for 2-3 seconds. All the used segments on the LCD will be visible for a few seconds, followed by a percent indication of the remaining battery life (E. g. Taking measurements Submerge the probe in the solution to be tested. Use plastic beakers to minimize any electromagnetic interferences. Select either EC or TDS mode with the SET/HOLD button. The measurements should be taken when the stability symbol on the top left of the LCD disappears. The EC (or TDS) value automatically compensated for temperature is shown on the primary LCD while the secondary LCD shows the temperature of the sample. To change the temperature unit To change the temperature unit (from °C to °F), from measurement mode, press and hold the /MODE button until TEMP and the current temperature unit are displayed on the lower portion of the LCD (E. g. Use the SET/HOLD button to change the temperature unit, and then press the /MODE button twice to return to the normal measuring mode. To freeze the display Press the SET/HOLD button for 2-3 seconds until HOLD appears on the secondary display. Press either button to return to the normal measuring mode. To turn the meter off Press the /MODE button while in normal measuring mode. OFF will appear on the lower part of the display. Notes: · Before taking any measurement make sure the meter has been calibrated. · If measurements are taken in different samples successively, rinse the probe thoroughly to eliminate cross-contamination; and after cleaning, rinse the probe with some of the sample to be measured.
CALIBRATION
For better accuracy, frequent calibration of the instrument is recommended. In addition, the instrument must be recalibrated whenever: a) The EC/TDS probe is replaced. [. . . ] To reset to the default calibration To clear a previous calibration, press the MODE button after entering the calibration mode. The lower LCD will display ESC for 1 second and the meter will return to normal measurement mode. The CAL symbol on the LCD will disappear. The meter will be reset to the default calibration.
PROBE MAINTENANCE
The EC/TDS probe can be easily replaced by using the supplied tool (HI 73128). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 98311
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.