If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 145-00. We hope that this HANNA INSTRUMENTS HI 145-00 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 145-00.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 145-00 (40 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 145-00
Detailed instructions for use are in the User's Guide.
[. . . ] SPECIFICATIONS: HI 145-00 HI 145-20
Instruction Manual
HI 145-01 HI 145-30
°C
Range
-50. 0 to 220°C
°F
-58. 0 to 428°F
Resolution 0. 1°C(-50 to199°C) 0. 1°F(-20. 0 to 199°F) 1°C(200 to 220°C) 1°F (200 to 428°F) Accuracy
±0. 3°C (-20 to 90°C) ±0. 5°F (-4 to 194°F) ±0. 4% F. S. (outside) ±0. 4% F. S. (outside) ±0. 3°C ±0. 5°F
HI 145-00 HI 145-01 HI 145-20 HI 145-30
Rugged Waterproof Thermometers
Typical EMC Deviation Battery Type Battery Life
Alkaline 1 x 1. 5V AAA type approx. 10, 000 hours of continuous use
Dimensions HI145-00/HI 145-01 92x165x38 mm (3. 6x6. 5x1. 5") HI145-20/HI 145-30 92x340x38 mm (3. 6x13. 4x1. 5")
SUGGESTIONS FOR USERS:
Before using this product, make sure that it is entirely suitable for the environment in which it is used. [. . . ] HI 145-20 (Celsius) and HI 145-30 (Fahrenheit) have been especially designed for temperature measurement of hot liquids. The stainless steel probe is 300 mm (12") long and has a 5mm (0. 2") diameter.
semi-solid samples. A minimum immersion level of 4 cm (1 ½") is recommended. · Wait for a few seconds for the display to stabilize. · To freeze the display, press the hold button. A blinking M appears on the right side of the LCD to indicate that reading has been memorized. Press either the HOLD 20. 0 M or ON/OFF button to return to normal measurement mode.
ON OFF
HOLD
HI 145
· When not in use, switch the HI 145 off, or else the meter will automatically switch off itself after 8 minutes.
· Variations in readings or fading display can
indicate a weak battery (see below).
OPERATION: · Turn the HI 145 on. "CAL" will appear on the LCD, to indicate an automatic calibration check. Subequent to a successful cali20. 0 bration check, the LCD will display "-0-". If the calibration check is unsuccessful, the LCD will display "ERR", which means the meter requires factory calibration. [. . . ] Battery should only be replaced in a safe area using an alkaline type. PROTECTIVE CAP: With the thermometer, is supplied with a protective cap, which can also be used to hold the thermometer on the side of a vessel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 145-00
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.