If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 146-00. We hope that this HANNA INSTRUMENTS HI 146-00 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 146-00.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 146-00 (302 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 146-00
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual &
(HI 146-00 & HI 146-01)
Thermometers
Dear Customer, Thank you for choosing a Hanna product. Please read carefully this manual before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] Liquid Crystal Display
SPECIFICATIONS
HI 146-00 Range -50. 0 to 150. 0°C Resolution 0. 1°C Accuracy ±0. 3°C (-20 to 90°C), ±0. 5°C (outside) Typical EMC Deviation ±0. 3°C HI 146-01 Range -58. 0 to 302°F Resolution 0. 1°F (-58. 0 to 199. 9°F), 1°F(200 to 302°F) Accuracy ±0. 5°F (-4 to 194°F), ±1°F (outside) Typical EMC Deviation ±0. 5°F Common Specifications Probe Stainless steel probe with 2 m (6. 6') cable Battery Type 1 x 1. 5V AA alkaline Battery Life approx. 5 years Casing IP54 Environment 0 to 50°C (32 to 122°F); RH max 95% Dimensions 86 x 110 x 43 mm (3. 4 x 4. 3 x 1. 7'') Weight 150 g (5. 3 oz. )
OPERATIONAL GUIDE
OPERATION · Dip the probe in the sample. An immersion level of 4 cm (1 ½") is recommended. · Do NOT immerse the probe handle. · Do NOT wrench the probe or put heavy objects on the cable. If the cable is damaged, the meter needs to be replaced. · Wait for a few seconds for the display to stabilize. · Variations in readings or fading display can indicate a weak battery. CALIBRATION CHECK SWITCH Remove the back cover and move the internal switch to the "TEST" position. The display should show 0. 0±0. 3°C (32. 0°F±0. 5°F).
Contact your dealer or the nearest Hanna Service Center for recalibration, if necessary. To return to the measurement mode, move back the switch to "MEAS" position. Replace the back cover and tighten the screws.
CE DECLARATION OF CONFORMITY
Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. [. . . ] If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 146-00
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 146-00 will begin.