If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 3873. We hope that this HANNA INSTRUMENTS HI 3873 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 3873.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 3873 (109 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 3873
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
SPECIFICATIONS
INSTRUCTIONS
-
· It is better to match the color with a white sheet at about 10 cm behind the comparator.
HI 3873 Nitrite Test Kit
Range Smallest Increment Analysis Method Sample Size Number of Tests Case Dimensions Shipping Weight
0 to 1. 0 mg/L (ppm) as NO2 -N 0. 2 mg/L (ppm) NO2--N Colorimetric 10 mL 100 230x59x70 mm (9. 0x2. 3x2. 8") 169 g (6. 0 oz. )
READ THE ENTIRE INSTRUCTIONS BEFORE USING THE KIT · Fill the glass cuvet with 10 mL of the sample, up to the mark. [. . . ] Nitrosation reactions of nitrites can yield organic nitrosamines, which are known to be carcinogenic. Note: mg/L is equivalent to ppm (parts per million).
· To convert the reading to mg/L of Nitrite (NO 2-), multiply the reading by a factor of 3. 29.
www. hannainst. com
· Replace the cap and shake gently until the powder is dissolved. A deposit may remain but it will not affect the reading. · Wait for 6 minutes to allow the color to develop. Remove the cap and fill the color comparator cube with 5 mL of the treated sample (to the mark).
REFERENCES
Adaptation of the EPA approved method 354. 1.
Note: Any damaged or defective item must be returned in its original packing materials.
ISTR3873
12/99
Dear Customer, Thank you for choosing a Hanna Product. Please read the instructions carefully before using the chemical test kit. It will provide you with the necessary information for correct use of the kit. Remove the chemical test kit from the packing material and examine it carefully to make sure that no damage has occurred during shipping. [. . . ] The amount of color developed is proportional to the concentration of nitrite present in the aqueous sample.
PRINTED IN ITALY
· Determine which color matches the solution in the cube and record the result in mg/L (or ppm) of Nitritenitrogen. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 3873
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 3873 will begin.