User manual HANNA INSTRUMENTS HI 8564

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 8564. We hope that this HANNA INSTRUMENTS HI 8564 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 8564.


Mode d'emploi HANNA INSTRUMENTS HI 8564
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 8564 (436 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 8564

Detailed instructions for use are in the User's Guide.

[. . . ] 2 Functional Description of HI 93640 . . . . . . . . . . . 3 Specifications of HI 8564 . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Specifications of HI 93640 . . . . . . . . . . . . . . . . . . . . . . . . 5 Operational Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] probe 3) Liquid Crystal Display 4) ON/OFF Key (to switch on/off) 5) RH% Key (to display RH measurements) 6) 7) O O 7) Shielded Cable 8) Low RH Trimmer 9) Low Temperature Trimmer 10) High RH Trimmer 11) High Temperature Trimmer 12) Polypropylene Probe Body 13) Protective Cover (to prevent damage to sensor) Display Indicators: "OC" (to indicate Temperature readings in degrees Centigrade) "H" (to indicate Relative Humidity readings) "V" (to indicate that battery needs to be replaced) F Key (to display Temperature in Fahrenheit) C Key (to display Temperature in Centigrade) Display Indicators: "OC" (to indicate Temperature readings in degrees Centigrade) "H" (to indicate Relative Humidity readings) "V" (to indicate that battery needs to be replaced) 2 3 SPECIFICATIONS OF HI 8564 SPECIFICATIONS OF HI 93640 RANGE RH °C °F 10. 0 to 95. 0% 0. 0 to 60. 0 32 to 140 RANGE RH °C °F 5. 0 to 95. 0% 0. 0 to 60. 0 32 to 140 RESOLUTION RH °C °F ACCURACY (@20°C / 68°F) RH °C °F 0. 1% 0. 1 1 RESOLUTION RH °C °F ACCURACY (@20°C / 68°F) RH °C °F 0. 1% 0. 1 1 +2% +0. 4 +1 for one year, excluding probe error +2% +0. 4 +1 for one year excluding probe error TYPICAL EMC DEVIATION RH °C °F OPERATING CONDITIONS BATTERY +2% +0. 5 +1 0 to 50 oC (32 to 122 oF) 98% RH max. One 9V, 100 hours of continuous use, with low battery indicator TYPICAL EMC DEVIATION RH °C °F OPERATING CONDITIONS BATTERY ±3% ±0. 4 ±0. 8 0 to 50oC (32 to 122oF) 98% RH max. One 9V, 100 hours of continuous use, with low battery indicator 190 x 80 x 38 mm (7. 5 x 3. 1 x 1. 5") 320 g (11. 3 oz. ) DIMENSIONS Meter Probe 185 x 82 x 45 mm (7. 3" x 3. 2" x 1. 8") L:165 mm D:25 mm with 2 m cable (L:6. 5" D:1" 7' cable) DIMENSIONS WEIGHT WEIGHT Meter Probe 315 g (11. 1 oz. ) 200 g (7 oz. ) 4 5 OPERATIONAL GUIDE INSTRUMENT PREPARATION Each meter is supplied complete with a 9V battery. Slide off the battery compartment cover on the back of the meter (see page 12), unwrap the battery and install it. To prepare HI 8564 for use connect the RH probe to the DIN socket on the top of the meter. be removed. Whenever the probe is to be used in a dusty or smoky environment, the filter must be kept on at all times. TEMPERATURE MEASUREMENTS Simply press the °C or °F keys to take the temperature readings directly from the same probe. Note: Press °C key to display the temperature in °C. °C "°C" is displayed when measuring temperature in degrees Centigrade. ON OFF Turn the meter on by pressing the ON/OFF key. ON OFF EXAMPLE: A temperature reading taken in degrees Centigrade would read: °C °C Using the HI 8564 or HI 93640 thermo-hygrometer is simple. However, the recommendations below should always be followed. RELATIVE HUMIDITY MEASUREMENTS · The end of the humidity detector should be exposed to a current of air moving at 0. 5 m (20") per second or more. · In the absence of air movement, the response can be accelerated by moving the probe. · The probe sensor must never come into contact with water or other liquids. If this should happen, or if condensation causes drops to form on the surface of the humidity sensor, turn off the instrument and wait until the liquid has evaporated completely. In order to accelerate the evaporation process, the humidity sensor could be exposed to a current of air. For HI 93640 only: in order to obtain a faster response, the sintered filter should 6 Press °F key to read the same value in degrees Fahrenheit: °F °F If you experience any problems in taking measurements, please contact your dealer or the nearest Hanna Instruments Customer Service Department. 7 CALIBRATION All Hanna hygrometers have been precalibrated at the factory. Hanna Instruments uses state-of-the-art thermal humidity chambers for this purpose. It is generally recommended to have all hygrometers recalibrated at least once a year. For an accurate annual recalibration, contact your nearest Hanna Service Center. You can also check the status of your HI 8564 and perform a quick recalibration (with an accuracy of ±5%) by using the Hanna mini-calibration chambers HI 7101. The kits are composed of two thermally isolated chambers, each one equipped with a threaded cap and three bottles containing the appropriate precalibrated saturated salts to produce a known RH value. Li Cl 11. 1% Na Cl 75. 4% · When the salt has dissolved completely, add all the content of the second bottle of HI 7111. · Allow the solution obtained to cool, and then pour it into the chamber marked "RH 11. 1%", making sure that no residue remains on the walls of the glass container. Li Cl 11. 1% Na Cl 75. 4% CALIBRATION KIT · Seal the chamber well when not in use, as the LiCl solution is extremely hygroscopic and tends to capture the humidity present in the air causing the solution to expand in volume and to overflow from the container. H 2 CALIBRATION KIT Preparing the (HI 8564 only): Calibration Solutions O H2 · Pour approximately 12 cc of distilled water into the other chamber marked "RH 75. 4%". Li Cl 11. 1% Na Cl 75. 4% CALIBRATION KIT · Pour approximately 26 cc of distilled water into a glass container. 26 cc · Immerse this container into a bath of ice and water and shake briefly. · Slowly add the contents of a HI 7111 bottle containing LiCl into the glass container while continuing to shake. 8 · Add all the content of the HI 7121 bottle containing NaCl while continuously shaking the container to avoid the formation of lumps. Seal this container well when not in use. The calibration kit needs 4 hours for stabilization. Li Cl 11. 1% Na Cl 75. 4% CALIBRATION KIT Li C l 12 9 3 6 9 l Li C O 12 cc Na Cl 4h RH Calibration Procedure (HI 8564 only): · Bring the calibration kit to a temperature of approximately 20°C. [. . . ] In HI 8564 the trimmers are sensitive to Electrostatic Discharge. It is recommended to use an antistatic screwdriver during calibration. Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24VAC or 60VDC. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 8564

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 8564 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag