User manual HANNA INSTRUMENTS HI 86301

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 86301. We hope that this HANNA INSTRUMENTS HI 86301 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 86301.


Mode d'emploi HANNA INSTRUMENTS HI 86301
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 86301

Detailed instructions for use are in the User's Guide.

[. . . ] These instruments are in compliance with the directives. SPECIFICATIONS TDS Models HI 86301 HI 86302 0 to 1999 ppm 0. 00 to 10. 00 ppt 1 ppm 0. 01 ppt ±2% f. s Manual, 1 point, through trimmer in the battery compartment Probe (included) HI 7634D/1 HI 7632D/1 Temp. Compensation Automatic, 0 to 50°C (32 to 122°F) with =2%/°C Environment 0 to 50 °C (32 to 122°F); RH max 100% Battery Type 1 x 9V alkaline Battery Life Approx. 150 hours Dimensions 164 x 76 x 45 mm (6. 4 x 3. 0 x 1. 8'') Weight 250 g (8. 8 oz. ) Range Resolution Accuracy Calibration PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. [. . . ] The BEPS (Battery Error Prevention System) automatically switches the meter off when the battery level is too low to ensure reliable readings. The housing has been completely sealed against humidity, for use in any type of environment. The probe is easy to clean and requires little maintenance. Choose the model with the measurement range that best fits your application: · HI 86301 reads TDS from 0 to 1999 ppm (mg/L) · HI 86302 reads TDS from 0. 00 to 10. 00 ppt (g/L) · HI 86303 reads EC from 0 to 1999 S/cm · HI 86304 reads EC from 0. 00 to 19. 99 mS/cm All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. TAKING MEASUREMENTS · Each meter is supplied complete with a 9V alkaline battery. Remove the battery compartment cover on the rear of the meter and install the battery while paying attention to the correct polarity (see also "Battery Replacement" section). · Connect the probe to the DIN plug on the top of the meter, and switch the instrument on by pressing the ON/OFF button. · Immerse the probe into the solution to be tested. For best accuracy, the probe should not touch or stand close to the vessel's walls or bottom. If possible, use plastic beakers to minimize any EMC interference. · Tap the probe gently on the bottom and shake it, to make sure no air bubbles have remained trapped inside. · Allow the reading to stabilize. The LCD will show the EC or TDS value automatically compensated for temperature effects. CALIBRATION · Pour a small quantity of the proper calibration solution in a beaker (HI 7031 for HI 86303, HI 7032 for HI 86301 and HI 86302, HI 7039 for HI 86304). If possible, use plastic beakers to minimize any EMC interference. · The calibration is a manual, 1-point procedure through trimmer. To access the calibration trimmer, remove the battery compartment cover on the rear of the meter. · Turn the meter on and immerse the probe in the calibration solution, making sure that the metal pins are completely submerged and the probe body does not touch nor stand close to the side walls of the beaker. · Tap the probe gently on the bottom and shake it, to make sure no air bubbles have remained trapped inside. [. . . ] Battery replacement must only take place in a nonhazardous area using a 9V alkaline battery. Unscrew the three screws on the rear of the meter, remove the battery compartment cover and replace the 9V battery with a new one. Make sure the battery contacts are tight and secure before replacing the cover. PROBE MAINTENANCE It is recommended to clean the probe at least once a month, by following this procedure: · Immerse the tip of the probe in the HI 7061 cleaning solution for half an hour. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 86301

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 86301 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag