If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 8711. We hope that this HANNA INSTRUMENTS HI 8711 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 8711.


Mode d'emploi HANNA INSTRUMENTS HI 8711
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 8711

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 8510 · HI 8512 HI 8710 · HI 8711 HI 8720 Panel Mounted pH and ORP Indicators and Controllers ORP HI 8720E mV DOSAGE OXID. REDUC. SLOPE AL MEA SURE SET COARSE SET FINE AL 0 mV TEST 500 mV TEST www. hannainst. com 0£ 1 PRELIMINARY EXAMINATION Dear Customer, Thank you for choosing a HANNA instruments® product. Please read this instruction manual carefully before using the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] Note: The electrode should be submerged at least 4 cm (1½") into the solution. The thermometer should be located as close as possible to the pH electrode. MEA SURE COARSE SET FINE Rinse pH electrode and thermometer probe thoroughly with water, then immerse them in pH4. 01 (HI 7004) or pH 10. 01 (HI 7010) buffer solution. Note: For accurate readings, use pH 4. 01 if you are going to measure acid samples or pH 10. 01 for alkaline measurements. Shake briefly and wait one minute before adjusting the slope trimmer to display the ph value of the buffer solution, i. e. pH 4. 01 (or 10. 01) at 25°C (77°F). °C 4 cm (1½") HI 7007 DOSAGE SLOPE ACID BASE O MEA SURE SET COARSE pH SET FINE °C HI 7004 If the buffer solution temperature is different from 25°C (77°F), refer to the "pH vs. temperaturare" chart on page 36 for the appropriate pH value at the noted temperature. The calibration is now complete and the instrument is ready for use. Note: If a Pt100 temperature sensor is used, immerse it into the buffer solutions during calibration. Shake briefly and wait one minute before adjusting the 0 trimmer to display the buffer solution value, i. e. "pH 7. 01" at 25°C (77°F). DOSAGE SLOPE 4 cm (1½") ACID BASE O MEA SURE SET COARSE pH SET FINE If the buffer solution temperature is different from 25°C (77°F), refer to the "pH vs. temperaturare" chart on page 36 for the appropriate pH value at the noted temperature. 34 34£ 35 pH VALUES AT VARIOUS TEMPERATURE Temperature has an effect on the pH. The calibration buffer solutions are affected by temperature changes to a lesser degree than normal solutions. Please refer to the following chart to perform the pH calibration: pH DIAGNOSTIC TESTS TEMP °C °F 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 32 41 50 59 68 77 86 95 104 113 122 131 140 149 158 4. 01 4. 01 4. 00 4. 00 4. 00 4. 00 4. 01 4. 02 4. 03 4. 04 4. 05 4. 06 4. 07 4. 09 4. 11 4. 12 6. 86 6. 98 6. 95 6. 92 6. 90 6. 88 6. 86 6. 85 6. 84 6. 84 6. 83 6. 83 6. 84 6. 84 6. 85 6. 85 pH VALUE 7. 01 9. 18 7. 13 7. 10 7. 07 7. 04 7. 03 7. 01 7. 00 6. 99 6. 98 6. 98 6. 98 6. 98 6. 98 6. 99 6. 99 9. 46 9. 39 9. 33 9. 27 9. 22 9. 18 9. 14 9. 10 9. 07 9. 04 9. 01 8. 99 8. 97 8. 95 8. 93 10. 01 10. 32 10. 24 10. 18 10. 12 10. 06 10. 01 9. 96 9. 92 9. 88 9. 85 9. 82 9. 79 9. 77 9. 76 9. 75 HI 8510, HI 8710 and HI 8711 are provided with autodiagnostic functions that allow to check and troubleshoot any malfunctioning. The functions are made via front panel keys to isolate the cause of malfunction whether it is due to pH electrode contamination, internal offset circuit or amplifier circuit. First press the MEASURE key, then one of the following keys. MEA SURE COARSE SET FINE A) Sensor Test Immerse the electrode in pH 7. 01 buffer solution (HI 7007), press SENSOR TEST key and the display shows the mV response of the electrode. 4 cm (1½") HI 7007 SENSOR TEST mV For instance, if the buffer temperature is 25°C (77°F), calibrate to read on the display pH 4. 01 or 7. 01 or 10. 01. If the buffer temperature is 20°C, calibrate to read on the display pH 4. 00 or 7. 03 or 10. 06. If the buffer temperature is 50°C, calibrate to read on the display pH 4. 06 or 6. 98 or 9. 82. If the electrode is in good working condition, the value should be within ±30 mV. A value between 30 and 60 mV or -60 and -30 mV, indicates some contamination of the electrode. If the value is higher than 60 mV or lower than -60 mV, the contamination is too high and the electrode should be replaced. 36 36£ 37 B) Internal Offset Circuit Test Press the pH7 TEST key and the display should show a value within 7±1 pH, to verify the internal circuit of the meter in terms of the offset compensation. ORP DIAGNOSTIC TESTS pH 7 TEST pH HI 8512 and HI 8720 are ORP controllers provided with autodiagnostic functions that allow to check and troubleshoot any malfunctioning. The functions are made via front panel keys to isolate the cause of malfunction. For HI 8720 only, press MEASURE key before proceeding with the following tests. MEA SURE C) Amplifier Circuit Test Press the pH4 TEST key and the display should show a value within the 3. 30 to 4. 30 pH range, to verify the amplifier circuit of the meter. COARSE SET FINE A) pH 4 TEST pH 0 mV Test Press the 0 mV TEST key and the display should show a value of 0±10 mV, to verify the "zero" calibration of the instrument. mV 0 mV TEST 500 mV TEST B) 500 mV Test Press the 500 mV TEST key and the display should show a value of 500±20 mV, to verify the slope at 500 mV. mV 0 mV TEST 500 mV TEST 38 38£ 39 LED INDICATION All LEDs above the keys indicate the state of each function, whether it is active or the display is indicating the mode. For HI 8711 only Each LED can be in one of the following states: A) Light on The mode is displayed on the LCD but is not active, e. g. the alarm setpoint is displayed but the alarm contact is open. TAKING REDOX MEASUREMENTS Redox measurements allow the quantification of the solution oxidizing/reducing power, and are commonly expressed in mV. [. . . ] When shipping any instrument, make sure it is properly packaged for complete protection. Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. The trimmers are sensitive to electrostatic discharges. It is recommended to use antistatic screwdrivers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 8711

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 8711 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag