If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 9161. We hope that this HANNA INSTRUMENTS HI 9161 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 9161.


Mode d'emploi HANNA INSTRUMENTS HI 9161
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 9161

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 9161 · HI 91610 Printing and Logging Thermo-Hygrometers instru m en ts MICR THE OPROC RMO E HYG SSOR P ROM R ETE INTING R HI 91 61C ON/O FF PAP E R RAN G %RH E °C -2 5. 0 . . . 95 0. 0 . . + . 0 60. 0 INTV UP DOW RAN N GE PRIN T LOG www. hannainst. com Dear Customer, Thank you for choosing a HANNA instruments® product. Please read this instruction manual carefully before using the instrument. This manual will provide you with the necessary information for the correct use of the instrument, as well as a precise idea of its versatility. [. . . ] The temperature value is always displayed together with the "°C" or "°F" symbol. a ­ Curernt log number b ­ Current sample number in that particular log c ­ Date (DD-MM-YY) d ­ Printing interval in minutes e ­ Time (HH. MM) f ­ RH% value g ­ Temperature value When the meter is in recording mode, LOG is displayed on the secondary LCD with the RH% value on the primary LCD. LOG 16 17 Press the RANGE key to read the temperature on the primary display. PRINTING/LOGGING WITH HI 91610 RANGE If no key is pressed, after approximately 5 minutes, the meter goes in standby mode to save the battery life. Note: If PRINT is pressed while still in recording mode, a printout is produced without affecting the running number. 10-01-96 0005M -- 05 -*11. 51 65. 2 RH% 25. 0 °C To print the values shown on the display, press PRINT. PRINT PRINT Printing during recording This function can be activated in normal operation mode as well as during logging (and scanning) modes. When in the measurement mode, each printout provides the following information: a ­ Running sample number b ­ Date (DD-MM-YY) 15-01-96 0001 *11. 20 c ­ Time (HH. MM) 65. 6 RH% d ­ RH% value 25. 0 °C e ­ Temperature value <> a b c d e TO STOP RECORDING To exit the recording mode, press ON/OFF. The instrument will make one final exit printout. 10-01-96 --01 -<> 0006 0005M *12. 01 65. 1 RH% 25. 0 °C LOGGING MODE WITHOUT PRINTING This function is particularly useful when measurements have to be taken continuously even in the absence of an operator over a long period of time. In this mode data will be stored directly into memory. Press the ALT and LOG keys simultaneously to enter the logging mode. The current log number and remaining page numbers will appear for a few seconds on the display to indicate the correct operational mode. The printer will print a complete set of data and the "LOG" symbol will appear on the secondary LCD. ON/OFF The running log number can be reset by simply removing the batteries. ALT UP DOWN RANGE TIME LOG Press the ALT and PAPER keys at the same time and the "LOG" symbol on display will start to blink. PRINT PAPER ALT UP If no key is pressed, after approximately 5 minutes the display will switch itself off but the logging function remains active. 18 19 Each printout provides the following information: To reactivate the display press the TIME key. Notes: · Once in the logging mode, the interval cannot be changed. Exit the logging mode (press ALT and LOG together) and then set the new interval. · If the PRINT key is pressed while in logging mode, a printout is produced without affecting the running sample number. PRINT TIME a b 14-01-96 --01-<> 0015 0001M *15. 01 65. 9 RH% 25. 4 °C c d e f SAMPLE NUMBER During logging it is possible to know the running sample number. Press the LOG key twice and the display will show the running number in the current log together with sample number symbol "Sn". g a ­ Current log number b ­ Current sample number (in that particular log) c ­ Date (DD-MM-YY) d ­ Printing interval in minutes e ­ Time (HH. MM) f ­ RH% value g ­ Temperature value 2x LOG LOG It is always possible to switch from the logging with printing function to logging without printouts. Press ALT and PAPER at the same time and the "LOG" symbol will start blinking to indicate that the data is now stored into memory but no longer printed. PRINT PAPER LOGGING MODE WITH PRINTING This function is useful in a variety of applications from unsupervised monitoring to satisfying regulatory requirements. In addition to the printouts, the measurements are also stored into the memory. Press the ALT and LOG key simultaneously to enter the logging mode. The current log number and the remaining page number will be displayed for a few seconds to indicate the correct operational mode. LOG ALT UP ALT UP DOWN LOG RANGE TIME LOG The printer will print a complete set of data and the "LOG" symbol will appear on the secondary LCD. If no key is pressed, the display turns off after about 5 minutes and comes back on only to print at the next logging interval. During printing, the display shows the time, preselected interval and "LOG" symbol. To reactivate the display press the TIME key. TIME Notes: · It is recommended to use an external power supply during logging with printing mode, especially if many printouts are required. · Before proceeding with logging/printing, make sure there is enough paper for your measurements. There is no warning if the machine runs out of paper. [. . . ] All HANNA temperature probes are supplied precalibrated from the factory, ready to be used with your meter. Models with different handle colors are available to avoid cross contamination during testing. HI 762A Air probe with 1 m (3. 3') cable and white handle HI 762A/10 Air probe with 10 m (33') cable and white handle HI 762BL Liquid probe with 1 m (3. 3') cable & black handle HI 762BL/10 Liquid probe with 10 m (33') cable & black handle HI 762L Liquid probe with 1 m (3. 3') cable & white handle HI 762L/10 Liquid probe with 10 m (33') cable & white handle HI 762PBL Penetration probe, 1 m (3. 3') cable & blue handle HI 762PBL/10 Penetration probe, 10 m (33') cable & blue handle HI 762PG Penetration probe, 1 m (3. 3') cable & green handle HI 762PG/10 Penetration probe, 10 m (33') cable & green handle HI 762PR Penetration probe, 1 m (3. 3') cable and red handle HI 762PR/10 Penetration probe, 10 m (33') cable and red handle HI 762PW Penetration probe, 1 m (3. 3') cable & white handle HI 762PW/10 Penetration probe, 10 m (33') cable & white handle HI 762W Wire probe, without handle (hard-to-reach places) with 1 m (3. 3') cable HI 762W/10 Wire probe, without handle (hard-to-reach places) with 10 m (33') cable 32 OTHER ACCESSORIES HI 710005 HI 71006 115 Vac / 12 Vdc power adapter, US plug 230 Vac / 12 Vdc power adapter, European plug HI 9200 HI 92000 HI 710034 HI 710035 HI 721317 Infrared transmitter Windows® compatible software Paper roll (10 pcs) Ink cartridge Rugged carrying case Windows ® is a registered Trademark of "Microsoft Co. " 33 HI 7101 HI 7102 HI 7111/P HI 7121/P RH calibration chamber RH calibration chamber for probes with sintered cap Spare saturation LiCl salts for low humidity calibration (15 g, 6 pcs) Spare saturation NaCl salts for high humidity calibration (33 g, 6 pcs) CE DECLARATION OF CONFORMITY CALIBRATION TEST KEYS HANNA test keys provide a quick and easy way to test the meter's accuracy by simply plug the key to the probe socket on the meter. If the reading differs by more than ±0. 4°C (±0. 8°F) from the test key value, the unit is due for recalibration. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 9161

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 9161 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag