If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 935005N. We hope that this HANNA INSTRUMENTS HI 935005N user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 935005N.
Manual abstract: user guide HANNA INSTRUMENTS HI 935005N
Detailed instructions for use are in the User's Guide.
[. . . ] This warranty is limited to repair or replacement free of charge. Damages due to accidents, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. [. . . ] Note: The ALT key can be released before pressing the second function key for 1-hand operation. ALT/ CAL : press and hold for about 5 seconds to enter the Calibration mode (with reading within ±3°C range). (ALT +) AOFF : set auto power off delay (8min, 60min, disabled). (ALT +) °C/°F : change reading units (°C or °F). (ALT +) BL : toggle the backlight ON and OFF.
7
OPERATIONAL GUIDE
To switch the instrument ON, press the ON/OFF key. The thermometer will carry out a self diagnostic test routine, the LCD will show all segments for a few seconds (or as long as ON/OFF is held), followed by the percentage indication of the remaining battery life.
HOLD mode. Note: Although the display is frozen, internally the meter continues measuring and updating Hi/Lo and relative values. In HI 935009 only, the held value is also stored in non-volatile memory and can be recalled by pressing (ALT+) MR key. While the MR key is held, the "HOLD" tag lights up and the meter displays the stored value; when the MR key is released, after 1 second the meter returns to normal measurement mode.
The thermometer then enters normal measurement mode. If a temperature probe is plugged in, the meter displays the measured temperature. If no probe is plugged in, or if the reading is over-range, the display shows flashing dashes. If a measurement is slightly over the range of the meter specifications, the display will flash the closest full-scale value. To switch the meter OFF, press the ON/OFF key.
HIGH/LOW TEMPERATURES
The maximum and minimum temperatures are continuously monitored and displayed on the lower portion of the LCD. Note: When the reading goes over-range or the probe is removed, the Hi and Lo values display dashes until cleared.
CLEAR FUNCTION
Upon pressing the CLR key, the High/Low values may be cleared at any time during measurement and the current reading is assigned to the highest and lowest temperature values for the displayed channel only.
°C/°F SELECTION
Measurements can be displayed in either degrees Celsius or Fahrenheit. The meter is factory set to °C scale; to change the scale, press °C/°F key or (ALT+) °C/°F keys,
AUTO SHUT-OFF (HI 935005 and HI 935009)
HI 935005 / 5005N HI 935009
or set the switch located in the battery compartment (HI 935002 only, see figure on page 10).
HOLD and MR FUNCTIONS
The HOLD function is activated by pressing the HOLD key. The measured temperature is held on the display until HOLD is pressed again. The "HOLD" tag blinks on the display while in
8
To save battery life, the HI 935005 and HI 935009 models are provided with an auto-off feature, which switches the instrument off after a certain period of nonuse. The delay time can be changed by the user (8 minutes, 60 minutes, or disabled). To access this feature, the HI 935005 is provided with an internal button located in the battery compartment (see figure on page 10). Unscrew the 4 screws on the back of the meter and select the desired auto-off time period by pressing the button and viewing the value on the LCD. Re-attach the back making sure that the gasket is in place and tighten the 4 screws to ensure a watertight seal.
9
HI 935009 allows the user to select the auto-off time period through the front keyboard; press (ALT+) AOFF to enter the mode, then set the desired auto shut-off interval (8 min, 60 min, or disabled) with the ALT key; release all buttons, wait a few seconds and the meter will return to normal measurement mode.
2-CHANNEL MODELS (HI 935002 and HI 935009)
HI 935002 and HI 935009 models can monitor two samples through two independent temperature channels (probes). The display will show the actual, Hi and Lo (or T1 and T2) values of the selected channel (T1, T2 or T1-T2). [. . . ] (03) 3258. 9565 · Fax (03) 3258. 9567
Korea:
Tel. (02) 2278. 5147 · Fax (02) 2264. 1729
Malaysia:
Tel. (603) 5638. 9940 · Fax (603) 5638. 9829
Singapore:
Tel. 6296. 7118 · Fax 6291. 6906
South Africa:
Tel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 935005N
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 935005N will begin.