User manual HANNA INSTRUMENTS HI 95759

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 95759. We hope that this HANNA INSTRUMENTS HI 95759 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 95759.


Mode d'emploi HANNA INSTRUMENTS HI 95759
Download
Manual abstract: user guide HANNA INSTRUMENTS HI 95759

Detailed instructions for use are in the User's Guide.

[. . . ] If the cap is properly installed, then contact your dealer or the nearest Hanna Customer Service Center. The blinking "BAT" indicates that the battery voltage is getting low and the battery needs to be replaced. PRELIMINARY EXAMINATION Please examine this product carefully. Make sure that the instrument is not damaged. If any damage occured during shipment, please notify your Dealer. [. . . ] ±0. 1% Transmittance Light Source Tungsten lamp with narrow band interference filter @ 560 nm Method Direct Measurement Light Detector Silicon Photocell Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Battery Type 1 x 9 volt Auto-Shut off After 10' of non-use Dimensions 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") Weight 290 g (10 oz. ) REQUIRED STANDARD Description Glycerol This indicates that the battery is dead and must be replaced. Once this indication is displayed, the meter will lock up. "Configuration": this indicates that the meter has lost its configuration. Contact your dealer or the nearest Hanna Customer Service Center. ERROR MESSAGES a) on calibration This indicates that the calibration procedure failed due to a low signal-tonoise ratio. "No Light": the instrument cannot adjust the light level. Please check that the sample does not contain any debris. Quantity/test 4 mL "Light Low": there is not enough light to perform a measurement. Please check the preparation of the Glycerol cuvet. "Light High": there is too much light to perform a measurement. Please check the preparation of the Glycerol cuvet. b) on sample reading There is too much light for the sample measurement. Please check if the right sample cuvet is inserted. "Cal": calibration was not performed. Follow the instruction in the operational guide for calibrating the meter. A blinking "100. 0" on sample reading is a warning that the Glycerol Reference cuvet is still inserted in the instrument, or indicates that the sample absorbs less light than the Glycerol Reference. Check the procedure and recalibrate the instrument. · Do not use the same cuvet with glycerol for more than 5-10 times to perform calibration and dispose of it after 1 day has passed. · Never re-use maple syrup sample cuvets, dispose of them after use. · Use one syringe for glycerol, and the other one for syrup in order to avoid contamination. Note: Maple Syrup samples exposed to direct sunlight and/or air will darken over time. This is caused by microorganisms. · Remove the Glycerol cuvet. · Use the second syringe to add to a clean cuvet 4 mL of maple syrup, up to 5 mm (0. 2") below the rim. ANALYSIS KIT C219/C220 Kit ACCESSORIES Kit for Maple Syrup analysis, including 82 cuvets, 30 mL of Glycerol and two 5 mL syringe (75 tests average) OPERATIONAL GUIDE · Turn the meter on by pressing ON/OFF. [. . . ] Always check clearness of cuvets prior to use. BATTERY REPLACEMENT Battery replacement must only take place in a non-hazardous area. Simply slide off the battery cover on the back of the meter. Detach the battery from the terminals and attach a fresh 9V battery while paying attention to the correct polarity. Replace the battery and replace the cover. Recommendations for Users Before using these products, make sure that they are entirely suitable for your specific application and for the environment in which they are used. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 95759

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 95759 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag