If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96706C. We hope that this HANNA INSTRUMENTS HI 96706C user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 96706C.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 96706C MANUAL 2 (1169 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 96706C
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
HI 96706C Phosphorus ISM
www. hannainst. com
This Instrument is in Compliance with the CE Directives
1
Dear Customer, Thank you for choosing a Hanna product. This manual will provide you with the necessary information for the correct use of the instrument. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] · GLP/ : this is a bi-functional key. In calibration mode press to edit the date and time. OPERATING MODES · Measurement mode: default operation mode, enables both validation and measurement. · Calibration mode: may be entered by keeping CAL CHECK pressed for three seconds (the "CAL" tag appears), it enables calibration of the instrument. · GLP mode may be entered by pressing GLP/ ("GLP" appears), it enables consulting of user calibration date or restore factory calibration. DISPLAY ELEMENTS DESCRIPTION
5 4 3 2 1 6 7 8 9 10
1) The measuring scheme (lamp, cuvet, detector), appears during different phases of zero or reading measurement 2) Error messages and warnings 3) The battery icon shows the charging level of the battery 4) The hourglass appears when an internal checking is in progress 5) Status messages 6) The chronometer appears when the reaction timer is running 7) The month, day and date icons appear when a date is displayed 8) Four digit main display 9) Measuring units 10) Four digit secondary display 8
ERRORS AND WARNINGS
The instrument shows clear messages when erroneous condition appears. Messages are also displayed when the obtained values are outside expected range. a) on zero reading Light High: There is too much light to perform a measurement. Please check the preparation of the zero cuvet.
Light Low: There is not enough light to perform a measurement. Please check the preparation of the zero cuvet.
No Light:The instrument cannot adjust the light level. Please check that the samples does not contain any debris.
b) on sample reading Inverted cuvets: The sample and the zero cuvet are inverted.
Zero: A zero reading was not taken. Follow the instructions of the measurement procedure for zeroing the meter.
9
Under range: A blinking "0. 0" indicates that the sample absorbs less light than the zero reference. Check the procedure and make sure you use the same cuvet for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates an over range condition. · It is possible to take multiple readings in a row, but it is recommended to take a new zero reading for each sample and to use the same cuvet for zeroing and measurement. · After the reading it is important to discard immediately the sample, otherwise the glass might become permanently stained. · All the reaction times reported in this manual are referred to 20°C (68°F). As a general rule of thumb, they should be doubled at 10°C (50°F) and halved at 30°C (86°F). · In order to maximize accuracy, prior to a measurement follow the validation procedure to be sure that the instrument is properly calibrated. 12
STARTUP
Prepare the instrument for measurement as follows: · Unpack the instrument by removing the dust protection sleeve from the instrument cuvet holder. · Place the battery in the instrument as described in the "BATTERY REPLACEMENT" chapter. · Place the instrument on a flat table. · Do not place the instrument under direct sun light.
MEASUREMENT PROCEDURE
To compensate the meter for the sample turbidity or color, the measurement takes place in two phases. [. . . ] · The instrument briefly notifies "done" when restores factory calibration and returns to measurement mode.
BATTERY MANAGEMENT
To save battery, the instrument shuts down after 10 minutes of non-use in measurement mode and after 1 hour of non-use in calibration mode. If a valid measurement was displayed before auto shut off, the value is displayed when the instrument is switched on. The blinking "ZERO" means that a new zero has to be performed. One fresh battery lasts for around 750 measurements, depending on the light level. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96706C
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.