User manual HANNA INSTRUMENTS HI 96770C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 96770C. We hope that this HANNA INSTRUMENTS HI 96770C user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS HI 96770C.


Mode d'emploi HANNA INSTRUMENTS HI 96770C
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS HI 96770C MANUAL 2 (1279 ko)

Manual abstract: user guide HANNA INSTRUMENTS HI 96770C

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual HI 96770C Silica High Range ISM www. hannainst. com This Instrument is in Compliance with the Directives 1 Dear Customer, Thank you for choosing a HANNA product. This manual will provide you with the necessary information for the correct use of the instrument. Please read it carefully before using the meter. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] · GLP/ : this is a bi-functional key. In calibration mode press to edit the date and time. OPERATING MODES · Measurement mode: default operation mode, enables both validation and measurement. · Calibration mode: may be entered by keeping CAL CHECK pressed for three seconds (the "CAL" tag appears), it enables calibration of the instrument. · GLP mode may be entered by pressing GLP/ ("GLP" appears), it enables consulting of user calibration date or restore factory calibration. DISPLAY ELEMENTS DESCRIPTION 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) Instrument status indicator appears during different phases of zero or reading measurement Icons displayed in this area are warning or action icons, signaling next operation The battery icon shows the charging level of the battery The hourglass appears when the instrument is performing an internal check up CAL: appears when the instrument operates in the calibration mode The month, day and date icons appear when a date is displayed The chronometer appears when the reaction timer is running Four digit main display Measuring units Four digit secondary display 8 ERRORS AND WARNINGS The instrument shows clear messages when erroneous condition appears. Messages are also displayed when the obtained values are outside expected range. a) on zero reading Light High: There is too much light to perform a measurement. Please check the preparation of the zero cuvet. Light Low: There is not enough light to perform a measurement. Please check the preparation of the zero cuvet. No Light: The instrument cannot adjust the light level. Please check that the samples does not contain any debris. b) on sample reading Inverted cuvets: The sample and the zero cuvet are inverted. Zero: A zero reading was not taken. As a general rule of thumb, they should be doubled at 10°C (50°F) and halved at 30°C (86°F). · In order to maximize accuracy, prior to a measurement follow the validation procedure to be sure that the instrument is properly calibrated. If necessary, calibrate the instrument. 11 START UP Prepare the instrument for measurement as follows: · Unpack the instrument by removing the cuvet holder protection from the instrument cuvet holder. · Place the battery in the instrument as described in the "BATTERY REPLACEMENT" chapter (see pag. 22). · Place the instrument on a flat table. · Do not place the instrument in direct sun light. MEASUREMENT PROCEDURE Turn the meter on by pressing ON/OFF and follow instruction manual to perform either the MEASUREMENT, VALIDATION or CALIBRATION PROCEDURE. · Turn the meter on by pressing ON/OFF. The display briefly shows all tags on. · When the beeper sounds and the LCD displays dashes, the meter is ready. The blinking "ZERO" indicates that the instrument needs to be zeroed first. · Fill the cuvet with 10 mL of unreacted sample, up to the mark, and replace the cap. · Place the cuvet into the cuvet holder and ensure that the notch on the cap is positioned securely into the groove. 12 · Press ZERO/CFM and the instrument status indicator will appear, depending on the measurement phase. · After a few seconds, the display will show "-0. 0-". The meter is now zeroed and ready for measurement. · Remove the cuvet. · Add the content of one packet of HI 96770A-0 Silica HR reagent A and shake until complete dissolution. · Remove the cap and add the content of one packet of HI 96770B-0 Silica HR reagent B. Replace the cap and shake vigorously dissolution. [. . . ] The instrument asks for confirmation before deleting the last calibration. · Press ZERO/CFM to restore the factory calibration or press GLP/ again to abort factory calibration restore. 20 · The instrument briefly notifies "done" when restores factory calibration and returns to measurement mode. BATTERY MANAGEMENT To save battery, the instrument shuts down after 10 minutes of non-use in measurement mode and after 1 hour of non-use in calibration mode. If a valid measurement was displayed before auto-shut off, the value is displayed when the instrument is switched on. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 96770C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 96770C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag