User manual HANNA INSTRUMENTS PH 209

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS PH 209. We hope that this HANNA INSTRUMENTS PH 209 user guide will be useful to you.

Lastmanuals help download the user guide HANNA INSTRUMENTS PH 209.


Mode d'emploi HANNA INSTRUMENTS PH 209
Download

You may also download the following manuals related to this product:

   HANNA INSTRUMENTS PH 209 (1048 ko)

Manual abstract: user guide HANNA INSTRUMENTS PH 209

Detailed instructions for use are in the User's Guide.

[. . . ] Instruction Manual pH 209-209R Bench-top pH Meter http://www. hannainst. com This Instrument is in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. This instrument is in compliance with directives. PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. [. . . ] TEMP °C °F 32 0 41 5 10 50 15 59 20 68 25 77 30 86 35 95 40 104 45 113 50 122 55 131 60 140 65 149 70 158 4. 01 4. 01 4. 00 4. 00 4. 00 4. 00 4. 01 4. 02 4. 03 4. 04 4. 05 4. 06 4. 07 4. 09 4. 11 4. 12 6. 86 6. 98 6. 95 6. 92 6. 90 6. 88 6. 86 6. 85 6. 84 6. 84 6. 83 6. 83 6. 84 6. 84 6. 85 6. 85 pH VALUES 7. 01 9. 18 7. 13 9. 46 9. 39 7. 10 9. 33 7. 07 9. 27 7. 04 9. 22 7. 03 9. 18 7. 01 9. 14 7. 00 9. 10 6. 99 9. 07 6. 98 9. 04 6. 98 9. 01 6. 98 8. 99 6. 98 8. 97 6. 98 8. 95 6. 99 8. 93 6. 99 10. 01 10. 32 10. 24 10. 18 10. 12 10. 06 10. 01 9. 96 9. 92 9. 88 9. 85 9. 82 9. 79 9. 77 9. 76 9. 75 ELECTRODE CONDITIONING AND MAINTENANCE Note: to prevent damage to the electrode, remove the pH electrode from the solution before turning the meter off. If the meter is OFF, detach the electrode from the meter before immersing the electrode in the storage solution. Reference Filling Hole Reference Filling Hole Sensitive Wire Reference Wire Reference Junction Glass Bulb Plastic Body pH Electrode Reference Wire Sensitive Wire Reference Junction Glass Bulb Glass Body pH Electrode For instance, if the buffer temperature is 25 C, the display should show pH 4. 01, 7. 01 or 10. 01 at pH 4, 7 or 10 buffers, respectively. At 20 C, the display should show pH 4. 00, 7. 03 or 10. 06. The meter reading at 50 C will then be 4. 06, 6. 98 or 9. 82. Reference Wire Reference Junction Platinum or Gold tip Reference Wire Reference Junction Platinum or Gold tip Glass Body ORP Electrode Plastic Body ORP Electrode PREPARATION Remove the protective cap. DO NOT BE ALARMED IF SALT DEPOSITS ARE PRESENT. This is normal with electrodes and they will disappear when rinsed with water. During transport tiny bubbles of air may form inside the glass bulb affecting proper functioning of the electrode. These bubbles can be removed by "shaking down" the electrode as you would do with a glass thermometer. If the bulb and/or junction is dry, soak the electrode in HI 70300 or HI 80300 Storage Solution for at least one hour. 10 11 For refillable electrodes: If the filling solution (electrolyte) is more than 2½ cm (1") below the fill hole, add HI 7082 or HI 8082 3. 5M KCl Electrolyte Solution for double junction or HI 7071 or HI 8071 3. 5M KCl+AgCl Electrolyte Solution for single junction electrodes. For a faster response, unscrew the fill hole screw during measurements. for single junction or HI 7082 or HI 8082 for double junction electrodes). Allow the electrode to stand upright for 1 hour. Follow the Storage Procedure above. CLEANING PROCEDURE Soak in Hanna HI 7061 or HI 8061 General Cleaning Solution for approximately ½ hour. Removal of films, dirt or deposits on the membrane/junction: Soak in Hanna HI 7073 or HI 8073 Protein Cleaning - Protein Solution for 15 minutes. - Inorganic Soak in Hanna HI 7074 or HI 8074 Inorganic Cleaning Solution for 15 minutes. - Oil/grease Rinse with Hanna HI 7077 or HI 8077 Oil and Fat Cleaning Solution. IMPORTANT: After performing any of the cleaning procedures rinse the electrode thoroughly with distilled water, refill the reference chamber with fresh electrolyte (not necessary for gel-filled electrodes) and soak the electrode in HI 70300 or HI 80300 Storage Solution for at least 1 hour before taking measurements. TROUBLESHOOTING Evaluate your electrode performance based on the following. · Noise (Readings fluctuate up and down) could be due to: ­ Clogged/Dirty Junction: Refer to the Cleaning Procedure above. ­ Loss of shielding due to low electrolyte level (in refillable electrodes only): refill with fresh HI 7071 or HI 8071 for single junction or HI 7082 or HI 8082 for double junction electrodes. · Dry Membrane/Junction: Soak in HI 70300 or HI 80300 Storage Solution for at least 1 hour. · Drifting: Soak the electrode tip in warm (approx. 50-60 C) Hanna HI 7082 or HI 8082 Solutions for one hour and rinse the tip with distilled water. [. . . ] Use: very high humidity. 12 mm 0. 5" "S" VERSION 120 mm 4. 7" FC 911 110 mm 4. 3" Ultem® is registered Trademark of "General Electrics Co. " Kynar® is registered Trademark of "Pennwalt Corp. " 18 19 Extension cables for screw-type electrodes (screw to BNC adapter) HI7855/1 Extension cable 1m (3. 3') long HI7855/3 Extension cable 3m (9. 9') long HI7855/5 Extension cable 5m (16. 5') long HI7855/10 Extension cable 10m (33') long HI7855/15 Extension cable 15m (49. 5') long HI 7855 SERIES CABLE CONNECTORS CONNECTOR AND 3. 0 mm (0. 12") CABLE WITH BNC ELECTRODE APPLICATION REFERENCE GUIDE Application 1. Aquarium Bath-water Beer Bread Cheese Dairy products Dirty water Emulsions Environment Flasks Food industry general use Fruit Fruit juices, organic Galvanizing waste solution Heavy-duty applications High purity water Horticulture In-line applications Laboratory general use Leather Lemon juice Meat Micro plate sampling of less than 100 mL Milk and Yogurt Paints Paper Photographic chemicals Quality control Sausages Semisolid products Skin Soil samples Solvents Strong acid Submersion application Surface measurements Swimming pool Titrations with constant temperature range Titrations with wide temperature range Very high humidity Vials and test tube Wine processing Electrodes HI 1332B, HI 1911B HI 1910B, HI 1130B HI 1131B HI 2031B, FC 200B FC 200B FC 911B, FC 100B HI 1910B, HI 1912B HI 1053B HI 1230B HI 1331B FC 911B, FC 100B FC 200B, FC 220B FC 210B HI 1130B, HI 1912B HI 1135B HI 1053B HI 1053B, FC 200B HI 1134B, HI 1135B, HI 2114B, HI 2910B HI 1131B, HI 1230B, HI 1332B, HI 1330B HI 1413B FC100B FC 200B, HI 2031B HI1083B FC 210B HI 1053B HI 1413B HI 1230B HI 1332B FC 200B, HI 2031B HI 2031B HI 1413B HI 1230B HI 1043B HI 1043B HI 1130B HI 1413B H I1130B, HI 2114B, HI 2910B HI 1131B HI 1131B FC 911B, HI 1912B, HI 1911B HI 1330B FC 220B CONNECT TO SCREW TYPE ELECTRODES CONNECT TO THE BNC SOCKET OF THE METER OTHER ACCESSORIES HI710005 HI710006 ChecktempC HI 76405 Voltage adapter from 115 VAC to 12 VDC Voltage adapter from 230 VAC to 12 VDC Pocket-size thermometer (range -50. 0 to 150. 0 C) Electrode holder HI 8427 pH and ORP electrode simulator with 1 m (3. 3') coaxial cable ending in female BNC connectors HI 931001 pH and ORP electrode simulator with LCD and 1 m (3. 3') coaxial cable ending in female BNC connectors 20 21 WARRANTY All Hanna Instruments meters are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. The electrodes and the probes are guaranteed for a period of six months. This warranty is limited to repair or replacement free of charge. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS PH 209

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS PH 209 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag