User manual HASE KAIRO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HASE KAIRO. We hope that this HASE KAIRO user guide will be useful to you.

Lastmanuals help download the user guide HASE KAIRO.


Mode d'emploi HASE KAIRO
Download

You may also download the following manuals related to this product:

   HASE KAIRO DATASHEET (154 ko)

Manual abstract: user guide HASE KAIRO

Detailed instructions for use are in the User's Guide.

[. . . ] This section contains important information on using this technical documentation. Utmost care was taken in preparing this document. Nevertheless, suggestions for improvement and comments regarding any errors are always welcome. This symbol alerts you to a potentially hazardous situation. [. . . ] The thermal output depends on the amount of fuel you put in the stove. When adding more fuel, please do not exceed the maximum fuel load size of 2, 5 kg. Exceeding the maximum fuel load size leads to a danger of overheating, which can result in damage to the stove and the risk of a stove fire. 5 kg and are no longer than 30 cm in length for about 55 min. 4, 5 kWm, burn wood logs that weigh 1 kg and are no longer than 25 cm in length for about 40 min. The surface of your stove was treated in a sandblasting machine before applying the colour coating. Despite careful and thorough inspection, there may still be some residual material in the stove body, which can fall out when your stove is being installed. To prevent any damage, please immediately vacuum up these small steel pellets with a vacuum cleaner. The first time a stove is operated, the heat development causes the emission of volatile components from the coating, sealing strips and lubricants, and smoke and odours can occur. At a higher combustion temperature, this one-time process can take between 4 to 5 hours. To achieve this higher combustion temperature, please increase the fuel quantity recommended in Section 7, , , Adding Fuel/ Heating with Nominal Thermal Output", by approximately 25%. To prevent adverse effects on health, nobody should stay in the room(s) during this process unless absolutely necessary. Room is well-ventilated and open the windows and outside doors. If needed, use a fan for faster air circulation. If the maximum temperature is not reached during the first heating operation, you may notice an odour for a short period of time the next time the stove is used as well. Procedure Open the throttle flap entirely, if your flue pipe has one Open shaking grate Open secondary and primary air slide completely Sweep remaining ash and any unburned charcoal into the centre with broom Place 2-3 small logs into the middle of the fire box; stack approx. Light the ignition material at several places. Light the material at several points Open fire box door Position of Control Elements Set handle of throttle flap along the length of the pipe Pull out shaking grate slide Pull out secondary and primary air slide (II) (fig. More fuel should be added to the fire when the flames from the previous burning off phase have just gone out. adding Fuel (Wood) Procedure Open the throttle flap entirely, if your flue pipe has one Set control elements Position of Control Elements Set handle of throttle flap along the length of the pipe. [. . . ] Piled up ashes can impair or even block the supply of primary air supply to the stove. Please ensure that the air supply path for the primary air between the ash drawer and the bottom of the ash compartment remains clear. 15 a B-VG (Austria), can only be operated when the fire box is closed; more than one device can be connected to the chimney. (A): RB BF1-Hn 1169 The following data applies to the chimney characteristics in accordance with EN 13384-1 / 2: Combustion Values Depending on the insulation of the building, the nominal thermal output of 9 kW indicated on 35 - 130 m² (subject to change) Dimensions: Stove Fire box Height 120, 5 cm 49 cm Width 86 cm 40 cm Depth 65 cm 31 cm 260 / 327 kg 1800 cm² 18 cm 10 cm The original Declaration of Conformity and associated documents are available from the manufacturer upon request. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HASE KAIRO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HASE KAIRO will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag