User manual HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE ASSEMBLY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE. We hope that this HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE user guide will be useful to you.

Lastmanuals help download the user guide HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE.


Mode d'emploi HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE
Download
Manual abstract: user guide HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSEASSEMBLY

Detailed instructions for use are in the User's Guide.

[. . . ] Assembly Instructions for cable gland: 151/RAC Industrial General Purpose Assembly Instructions AI 393 / Issue A - 08/09 Operating temperature range -60°C +80°C 1 2 Certification Details Gland Type: 151/RAC IP 66 Industrial BS 6121 Types CX, CW and CY Certified to Hawke Approved Drawings Only 3 4 5 Reversible Armour Clamping Ring (RAC) General identification ring orientation for: SWA Position Braid 'X', Flat Steel Wire 'Y', Steel Tape 'Z' Ring Position 1. 5. Backnut Middle Nut Reversible Armour Clamping Ring (RAC) Armour Spigot Entry (with captive deluge seal), if fitted IMPORTANT: The arrowhead indicating the correct armour thickness or type should point towards the equipment Cable Preparation Armour/braid Gland Preparation 5 II 4 3 4 I I 3 3 2 Note: Tape armour must be re-trimmed at 90° to the vertical axis of the cable after it has been spread, to ensure that the full face is correctly presented. 2 2 1 1 1 Shroud Option A Strip Cable to suit equipment as shown above and expose the armour/braid 'I'. [. . . ] UK www. ehawke. com Sales: +44 (0) 161 830 6698 Technical: +44 (0) 161 830 6697 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke. com 5 5mm minimum recommended 5 4 3 5 2 2 2 1 1 1 D Hold the entry in position with a spanner/wrench to prevent rotation. Hand tighten the middle nut to the entry and turn a further ½ to ¾ of a turn with a spanner/wrench. IMPORTANT: Support the cable to prevent it from twisting. To ease wiring inside the enclosure, it may be beneficial to strip the inner sheath of the cable as shown above. E Unscrew the middle nut and visually inspect that the armour/braid has been successfully clamped between the armour spigot and the armour clamping ring . If armour/braid not clamped, repeat assembly. F Reassemble middle nut onto the entry component . Tighten up the middle nut until hand tight, then using a wrench/spanner, turn the nut through one hex. Tighten the backnut to form a seal around the cable, then tighten a further full turn using a wrench/spanner. Ensure that the middle nut does not rotate when tightening the backnut . Ensure that the deluge seal is pulled down into position. Locate the shroud over the cable gland, if applicable CABLE GLAND SELECTION TABLE Cable Acceptance Details Entry Thread Size Size Ref. Metric Os O A B C C2 D E F M20 M20 M20 M25 M32 M40 M50 M63 M75 NPT ½" ½" ½" - ¾" ¾" - 1" 1" - 1¼" 1¼" - 1½" 1½" - 2" 2" - 2½" 2½" - 3" Inner Sheath Outer Sheath Steel Wire Armour/ Tape/Braid Orientation 1 0. 8/1. 25 0. 8/1. 25 0. 8/1. 25 1. 25/1. 6 1. 6/2. 0 1. 6/2. 0 1. 8/2. 5 1. 8/2. 5 1. 8/2. 5 Orientation 2 0/0. 8 0/0. 8 0/0. 8 0/0. 7 0/0. 7 0/0. 7 0/1. 0 0/1. 0 0/1. 0 73 73 74 82 88 91 113 117 115 Max Length Hexagon Dimensions Across Across Flats Corners 24. 0 24. 0 30. 0 36. 0 46. 0 55. 0 65. 0 80. 0 95. 0 27. 7 27. 7 34. 6 41. 6 53. 1 63. 5 75. 1 92. 4 109. 6 Max. 8. 0 11. 9 14. 3 20. 2 26. 5 32. 5 42. 3/44. 4 54. 3/56. 3 65. 3/68. 2 Min. [. . . ] Earthtag, to provide an external armour / braid bonding point. Serrated washer, to dampen any vibrations that may loosen the locknut or cable gland assembly. AI 393 - Issue A / Page 3 of 3 Multi-Orifice Seal X Impact Category Connection to Metallic Layers Insulation Characteristics Non-Metallic [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE 151-RAC INDUSTRIAL GENERAL PURPOSE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag