User manual HAWKE 153 ASSEMBLY AI 341 ISSUE K 05-06
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE 153. We hope that this HAWKE 153 user guide will be useful to you.
Lastmanuals help download the user guide HAWKE 153.
You may also download the following manuals related to this product:
HAWKE 153 ASSEMBLY AI 303 ISSUE N 12-08 (271 ko)
Manual abstract: user guide HAWKE 153ASSEMBLY AI 341 ISSUE K 05-06
Detailed instructions for use are in the User's Guide.
[. . . ] Assembly Instructions for cable gland type 153 9MX2
Class 1 Zone 1 AExe II Offshore Class 1 Zone 2 AExe II Onshore
See Schedule of Limitations : AExe
Assembly Instructions AI 341 Issue K - 05/06
Operating temperature range -20°C +70°C
Listing No. 6.
Backnut Middle Nut Braid Clamping Ring Braid Spigot Inner Seal Entry (with captive deluge seal), if fitted
1 2 3 4 6 5
1a
Please Note: For G, H & J size glands the part 1 will be substituted by part 1a.
Cable Preparation
Cable Gland Preparation
6 5
Braid
4 II I 3 2 3 2 1 4
3
2 1 1
Shroud option A Strip Cable to suit equipment as shown above and expose the braid 'I'. [. . . ] If braid not clamped, repeat assembly.
F Remove entry and refit inner seal , replace entry and re-assemble middle nut onto the entry component . Tighten up the middle nut using a wrench / spanner until resistance is felt between the seal and cable, then turn the middle nut through a further half a full turn to complete the inner seal. Tighten the backnut to form a seal around the cable, then tighten a further full turn using a wrench / spanner. Ensure that the middle nut does not rotate when tightening the backnut . Ensure that the deluge seal is pulled down into position, if fitted. Locate the shroud over the cable gland, if applicable.
AI 341 - Issue K / Page 2 of 4
CABLE GLAND SELECTION TABLE
Size Ref. Os O A B C C2 D E F G H J Entry Thread Size Metric M20 M20 M20 M25 M32 M40 M50 M63 M75 M80 M90 M100 Cable Acceptance Details Inner Sheath'A' Outer Sheath Standard Alternative 'B' Seal Seal (S) NPT Min. ½" 0. 12" 0. 31" 0. 22" 0. 47" ½" 0. 30" 0. 46" 0. 37" 0. 63" ½" 0. 44" 0. 56" 0. 34" 0. 52" 0. 49" 0. 81" ¾" 0. 52" 0. 79" 0. 38" 0. 60" 0. 66" 1. 02" 1" 0. 75" 1. 04" 0. 61" 0. 83" 0. 87" 1. 30" 1¼" 0. 99" 1. 27" 0. 87" 1. 10" 1. 10" 1. 61" 2" 1. 24" 1. 74" 1. 09" 1. 37" 1. 42" 2. 07" 2½" 1. 68" 2. 21" 1. 54" 1. 83" 1. 81" 2. 57" 3" 2. 15" 2. 68" 1. 91" 2. 29" 2. 24" 3. 07" 3½" 2. 63" 2. 87" 3. 05" 3. 52" 3. 05" 3. 52" 3½" 2. 63" 3. 05" 4" 2. 95" 3. 60" 3. 46" 4. 11" 'C' Wire Braid 'X' 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 0. 008"/0. 013" 'G' Hexagon Dimensions Across Across Flats Corners 0. 94" 1. 09" 0. 94" 1. 09" 1. 18" 1. 36" 1. 42" 1. 64" 1. 81" 2. 09" 2. 17" 2. 50" 2. 56" 2. 96" 3. 15" 3. 64" 3. 74" 4. 31" 4. 19" 4. 84" 4. 52" 5. 22" 5. 00" 5. 77"
3. 19" 3. 19" 3. 27" 3. 43" 3. 62" 3. 90" 4. 45" 4. 61" 4. 72" 4. 48" 4. 48" 4. 48"
Sizes Os and O are available with an M16 thread size. If M16 entry is used on O size Cable Glands the maximum cable inner sheath diameter is limited to 0. 43mm.
SCHEDULE OF LIMITATIONS: AExe 1. The cable glands when used with braided cable types are only suitable for use with fixed aparatus, the cable for which must be effectively clamped and cleated elsewhere. This cable gland has an operating temperature range of -20°C to +70°C. When the glands are used in increased safety applications a UL Listed sealing washer may be required between the external face of the enclosure and the gland sealing face in order to maintain the integrity of the increased safety enclosure. A grounding / earth tage has been provided for use as a grounding point when the cable gland is used with plastic enclosures. This must be fitted to the wall of the enclosure using the threads of the gland and the locknut supplied. [. . . ] Serrated washer to dampen any vibrations that may loosen the locknut or cable gland assembly.
AI 341 - Issue K / Page 3 of 4
Visit our Web Site at www. ehawke. com
AI 341 - Issue K / Page 4 of 4 Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. Sales: UK 0870 60 60 105 Sales: +44 (0) 161 830 6698 Technical UK: 0870 458 9358 Technical: +44 (0) 161 830 6697 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke. com
Safety First
International [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE 153
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE 153 will begin.