User manual HAWKE 153 INDUSTRIAL GENERAL PURPOSE ASSEMBLY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE 153 INDUSTRIAL GENERAL PURPOSE. We hope that this HAWKE 153 INDUSTRIAL GENERAL PURPOSE user guide will be useful to you.

Lastmanuals help download the user guide HAWKE 153 INDUSTRIAL GENERAL PURPOSE.


Mode d'emploi HAWKE 153 INDUSTRIAL GENERAL PURPOSE
Download

You may also download the following manuals related to this product:

   HAWKE 153 INDUSTRIAL GENERAL PURPOSE ASSEMBLY AI 321 ISSUE L 08-06 (231 ko)

Manual abstract: user guide HAWKE 153 INDUSTRIAL GENERAL PURPOSEASSEMBLY

Detailed instructions for use are in the User's Guide.

[. . . ] Assembly Instructions for cable gland: 153 Industrial General Purpose International Assembly Instructions AI 390 / Issue A - 08/09 Operating temperature range -60°C +80°C Os to F Sizes Certification Details 1 Gland Type: 153 IP66 Industrial Certified to Hawke Approved Drawings Only 2 3 1. Backnut Middle Nut Armour Clamping Ring Armour Spigot Inner Seal Entry (with captive deluge seal), if fitted 4 5 6 Cable Preparation Gland Preparation 6 Armour/braid 5 II 3 4 I I 4 3 3 2 2 Note: Tape armour must be re-trimmed at 90° to the vertical axis of the cable after it has been spread, to ensure that the full face is correctly presented. 2 1 1 1 Shroud Option A Strip cable to suit equipment as shown above and expose the armour/braid 'I'. 'I' = 20mm for cable gland sizes Os to C 'I' = 25mm for cable gland sizes C2 to H & J 'II' = to suit equipment. [. . . ] Hand tighten the middle nut to the entry and turn a further half to one full turn with a spanner/wrench. IMPORTANT: Support the cable to prevent it from twisting. To ease wiring inside the enclosure, it may be beneficial to strip the inner sheath of the cable as shown above. E Unscrew the middle nut and visually inspect that the armour/braid has been successfully clamped between the armour spigot and the armour clamping ring . If armour/braid not clamped, repeat assembly. F Remove entry and refit inner seal , replace entry and re-assemble middle nut onto the entry component . Tighten up the middle nut using a wrench/spanner until resistance is felt between the seal and cable, then turn the middle nut through a further half a full turn to complete the inner seal. Tighten the backnut to form a seal around the cable, then tighten a further full turn using a wrench/spanner. Ensure that the middle nut does not rotate when tightening the backnut . Ensure that the deluge seal is pulled down into position, if fitted. Locate the shroud over the cable gland, if applicable. CABLE GLAND SELECTION TABLE Cable Acceptance Details Size Ref. Entry Thread Size Metric Os O A B C C2 D E F M20 M20 M20 M25 M32 M40 M50 M63 M75 NPT ½" ½" ½" - ¾" ¾" - 1" 1" - 1¼" 1¼" - 1½" 1½" - 2" 2" - 2½" 2½" - 3" Min. 3. 0 6. 5 10. 0 12. 5 19. 0 25. 0 Inner Sheath Standard Seal Max. 8. 0 11. 9 14. 3 20. 2 26. 5 32. 5 Alternative Seal (S) Min. ----8. 5 9. 5 14. 5 22. 0 27. 5 39. 0 48. 5 Max. ----13. 4 15. 4 21. 2 28. 0 34. 8 46. 5 58. 3 Outer Sheath Standard Steel Wire 'W' 0. 8/1. 25 0. 8/1. 25 0. 8/1. 25 1. 25/1. 6 1. 6/2. 0 1. 6/2. 0 2. 0/2. 5 2. 5 2. 5 Wire Braid 'X' 0. 2/0. 35 0. 2/0. 35 0. 2/0. 35 0. 2/0. 45 0. 2/0. 45 0. 3/0. 45 0. 4/0. 45 0. 4/0. 45 0. 4/0. 45 Max Strip / Tape Length 'Z' Across Across Flats Corners 0. 2 - 0. 8 0. 2 - 0. 8 0. 2 - 0. 8 0. 2 - 1. 0 0. 2 - 1. 4 0. 2 - 1. 8 0. 2 - 1. 8 0. 2 - 1. 8 0. 2 - 1. 8 76 76 78 83 87 94 114 110 115 24. 0 24. 0 30. 0 36. 0 46. 0 55. 0 65. 0 80. 0 95. 0 27. 7 27. 7 34. 6 41. 6 53. 1 63. 5 75. 1 92. 4 109. 6 Hexagon Dimensions Min. [. . . ] Sealing washer, to offer additional ingress protection of the enclosure at the cable gland entry. Earthtag, to provide an external armour/braid bonding point. Serrated washer, to dampen any vibrations that may loosen the locknut or cable gland assembly. AI 390 - Issue A / Page 3 of 3 Multi-Orifice Seal Impact Category Connection to Metallic Layers Insulation Characteristics Non-Metallic [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE 153 INDUSTRIAL GENERAL PURPOSE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE 153 INDUSTRIAL GENERAL PURPOSE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag