[. . . ] Assembly Instructions for flange: 483 Exd I 484 Exd I
Assembly Instructions AI 344 / Issue M - 12/09 Certification Details
Flange Type: 483 and 484 Exd I Baseefa08ATEX0333U IM 2 IP66 IECEx BAS08. 0113U
483 Exd I
This is a component certified flange adaptor, ensure that apparatus certificate lists this component as acceptble.
A
`T'
`S'
`M' +0 / -0. 07
`K'
A
SECTION A-A
FLANGE ADAPTOR DIMENSIONS - 483
K O A B C C2 D E M P 6. 7 6. 7 9. 1 9. 1 R 11. 1 11. 1 15. 1 15. 1 18. 1 18. 1 20. 5 S 7. 0 7. 0 8. 7 8. 7 10. 5 10. 5 13. 5 T 4. 1 4. 1 4. 0 4. 0 3. 8 3. 8 4. 0
Fixing Screws
EQUIPMENT ENTRY HOLE SIZE - 483
MAX O A B C C2 D E 25. 70 25. 70 32. 05 38. 40 51. 10 63. 80 76. 50 MIN 25. 45 25. 45 31. 80 38. 15 50. 85 63. 55 76. 25
57. 15 25. 40 57. 15 25. 40 69. 85 31. 75 82. 55 38. 10
M6 M6 M8 M8 M10 M10 M10
95. 25 50. 80 11. 1 114. 30 63. 50 11. 1 127. 00 76. 20 14. 1
Connection Solutions
Hawke International is a division of Hubbell Ltd. [. . . ] UK
`V'
`P'
`R'
AI 344 - Issue M / Page 1 of 2 Sales: +44 (0) 161 830 6698 Technical: +44 (0) 161 830 6697 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke. com
www. ehawke. com
484 Exd I
This is a component certified flange adaptor, ensure that apparatus certificate lists this component as acceptble.
`S' `P' `R'
A
`T'
`M' +0 / -0. 07
36. 5
`V'
A
SECTION A-A
FLANGE ADAPTOR DIMENSIONS - 484
K O/A B C C2 D E F M P 6. 7 6. 7 9. 1 9. 1 R 11. 1 11. 1 15. 1 15. 1 18. 1 18. 1 20. 5 S 7. 0 7. 0 8. 7 8. 7 10. 5 10. 5 13. 5 T 4. 1 4. 1 4. 0 4. 0 3. 8 3. 8 4. 0
Fixing Screws
EQUIPMENT ENTRY HOLE SIZE - 484
MAX O/A B C C2 D E F 19. 35 25. 70 32. 05 38. 40 51. 10 63. 80 76. 50 MIN 19. 10 25. 45 31. 80 38. 15 50. 85 63. 55 76. 25
44. 45 19. 05 57. 15 25. 40 69. 85 31. 75 82. 55 38. 10
M6 M6 M8 M8 M10 M10 M10
95. 25 50. 80 11. 1 114. 30 63. 50 11. 1 127. 00 76. 20 14. 1
FOR BOTH 483 AND 484 Step 1 ( Prior to Installation) Ensure the holes in the equipment are compatable with the flange adaptor. Details of equipment entry hole sizes and relevant dimensions of the adaptor are shown in the tables. Step 2 Push the adaptor into the equipment entry hole and secure the adaptor to the enclosure using 2 socket cap head screws of the correct thread size. The length of the thread must be selected such that the screws do not bottom in the fixing holes. [. . . ] NOTE: Do not use a stopping plug to close off the female thread of adaptor.
AI 344 - Issue M / Page 2 of 2
`K' [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE 484 EXD I
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.