[. . . ] Hazardous Area Cable Glands 501/423 Application Flameproof and Increased Safety ATEX 'G' Approx(Compressed Length) 'H' The 501/423 cable gland provides two independant seals on non-armoured elastomer and plastic insulated cables. The first is a flameproof seal on the inner or outer cable sheath, with an additional IP seal on the outer sheath. [. . . ] Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10. 9mm. 3 Accessories including locknuts, sealing washers, serrated washers, earth tags, shrouds, adaptors and reducers are also available. Features Provides superior cable retention to standard unarmoured cable glands, with seal at two independant points. When used in increased safety applications, this cable gland may be used with braided cable where the braid and the outer sheath pass into the enclosure. The braid must then be suitably terminated inside the enclosure. Manufactured in brass (standard), nickel plated brass, 316 stainless steel or aluminium. Brass NPT entries are nickel plated as standard. Technical Data Flameproof Exd and Increased Safety Exe. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22. Suitable for use in Gas Groups IIA, IIB and IIC. Construction and test standards IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1. IP66, IP67 and IP68 (30 metres for 7 days) ingress protection to IEC 60529, EN 60529 and NEMA 4X. DTS01 deluge protection, certified by ITS. [. . . ] This document and all copyright therein is the property of: Hawke International a trading name of Hubbell Ltd (A member of the Hubbell Inc Group of Companies). Copyright Condition: This document shall be used only for the purpose for which it is provided and no reproduction or publication of the document may be made and no article may be manufactured or assembled in accordance with information contained in the document without prior written consent of the owner. GOST R-Exd IICU/Exe IIU. Exd IIC/Exe II/DIP A21 IP66. www. ehawke. com Connection Solutions International HWK102 August '08 Ø 'B' [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE 501-423

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE 501-423 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag