User manual HAWKE ZEZE 62 ASSEMBLY AI281 ISSUE H 12-08

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE ZEZE 62. We hope that this HAWKE ZEZE 62 user guide will be useful to you.

Lastmanuals help download the user guide HAWKE ZEZE 62.


Mode d'emploi HAWKE ZEZE 62
Download
Manual abstract: user guide HAWKE ZEZE 62ASSEMBLY AI281 ISSUE H 12-08

Detailed instructions for use are in the User's Guide.

[. . . ] Assembly Instructions for: ZEZE 22, 42 & 62 Enclosures IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Terminal Box CAT II 2G for use in Zone 1 or 2. Areas as defined in IEC/EN 61241-0 & 1. [. . . ] Unscrew the lid propr screw until it clears the hole in the lid. Lift the lid and swing the lid prop back inside the box. Tighten the M6 lid securing screws. TO REMOVE THE LID: 1. Disconnect power (isolate all circuits). Screw one of the hinge grub screws inwards until it clears the hole in the lid. Hold the lid securely and then screw the other grub screw inwards until it clears the hole in the lid. Remove the lid and place in an area where it will not be subject to damage or moisture. TO REPLACE THE LID: 1. Ensure the inside of the lid is dry and free from dust and foreign matter. Place the lid back onto the base and hold securely in position. Unscrew the hinge grub screws through the holes in the lid as far as possible. Tighten the M6 lid securing screws. ENCLOSURE INSTALLATION (EI) a) The IP rating of the enclosure must be maintained for the area of use (e. g. IP6* for Zone 21 dust environment) by the use of correct arrangement of cable/gland/sealing arrangements and in accordance with the installation codes as detailed in IEC/EN 60079-14 - IEC/EN 61241 and these installation instructions. [. . . ] This area, following installation, must be protected against corrosion. b) The earth leads must be at least equal to the cross section of the largest live conductor up to 16mm² or a minimum of 0. 5 x the maximum cross sectional area of the live conductor above 35mm², with a minimum cross sectional area of 16mm². AI 281 - Issue H / Page 2 of 2 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE ZEZE 62

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE ZEZE 62 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag