User manual HAWKE ZPL 6 SERIES ASSEMBLY AI272 ISSUE M 07-08
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAWKE ZPL 6 SERIES. We hope that this HAWKE ZPL 6 SERIES user guide will be useful to you.
Lastmanuals help download the user guide HAWKE ZPL 6 SERIES.
Manual abstract: user guide HAWKE ZPL 6 SERIESASSEMBLY AI272 ISSUE M 07-08
Detailed instructions for use are in the User's Guide.
[. . . ] Assembly Instructions for: ZPL 6** Series Enclosures
IMPORTANT: This document should be read carefully before commencing installation
Zones of Use of Terminal Box CAT II 2G for use in Zone 1. [. . . ] Locate and tighten all the lid securing screws into the box body. ENCLOSURE INSTALLATION (EI) a) The IP rating of the enclosure must be maintained for the area of use (e. g. IP6* for Zone 21 dust environment) by the use of correct arrangement of cable/gland/sealing arrangements and in accordance with the installation codes as detailed in IEC/EN 60079-14 - IEC/EN 61241 and these installation instructions. b) Where other certified components are part of the assembly, the user must take account of any limitations listed on relevant certificates. c) If an optional Breather/Drain as listed on the enclosure certificate is fitted the enclosure must be sited such that the Breather/Drain is pointing vertically downwards from the bottom of the box, and the IP rating of the selected Breather/Drain shall match the IP rating of the enclosure. d) The enclosure may be ready supplied with cable entries. Where the customer drills cable entries they must be installed in accordance with the component certificate BAS01ATEX2101U, Baseefa06ATEX0116U or IEC Ex No: BAS06. 0027U and enclosure limitations, these specify a maximum clearance on the entry thread of 0. 7mm for plain holes and where adjacent cable entries are installed sufficient clearance must be maintained to allow for the fitting of sealing/retaining washers and the rotation of the cable gland hexagons, and leave a minimum of material between adjacent holes inline with the above certificate number(s). e) All unused entry apertures must be sealed using a stopping plug as listed on the enclosure certificate and also the IP rating of the enclosure shall be maintained for the zone of use. [. . . ] UK
www. ehawke. com
AI 272 - Issue M / Page 1 of 1 Sales (UK): 0870 606 0105 Sales: +44 (0) 161 830 6698 Technical (UK): 0870 458 9358 Technical: +44 (0) 161 830 6697 Fax: +44 (0) 161 830 6648 E-mail: sales@ehawke. com
ZPL 612 = 74, ZPL 615 = 94, ZPL 620 = 128, ZPL 626 = 106. 5, ZPL 630 = 125
ZPL 626 = 160,
ZPL 626 = 144 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE ZPL 6 SERIES
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.