User manual HEAT AND GLO RED40ST

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HEAT AND GLO RED40ST. We hope that this HEAT AND GLO RED40ST user guide will be useful to you.

Lastmanuals help download the user guide HEAT AND GLO RED40ST.


Mode d'emploi HEAT AND GLO RED40ST
Download
Manual abstract: user guide HEAT AND GLO RED40ST

Detailed instructions for use are in the User's Guide.

[. . . ] Owner's Manual Installation and Operation Models: RED40 RED40ST NOTICE DO NOT DISCARD THIS MANUAL · Important operating and maintenance instructions included. · Read, understand and follow these instructions for safe installation and operation. · Leave this manual with party responsible for use and operation. D DI O N SC OT AR D WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. · DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. [. . . ] The intake vent cover provided with the appliance must be used. Note: The blower is essential for keeping components and the appliance environment in safe operating temperatures. H1 MAX. = TWO 90° BENDS INLET CONVECTION AIR MAY BE VENTED IN ANY DIRECTION, INCLUDING DOWNWARD. MIN. CLEARANCE FROM INTAKE TO OBJECTS = 24 IN. DO NOT terminate blower vent into an attic, crawl space, or the appliance chase. Vent must terminate on an adjacent, interior wall. NOTE: The 8 in. intake vent cover provided with the appliance must be used. Figure 9. 3. Active Convection Technology Duct and Termination. CONVECTION AIR DUCT 8 FT. MAXIMUM CONVECTION AIR DUCT Figure 9. 4. Active Convection Technology Duct Venting Specifications. Heat & Glo · RED40, RED40ST · 2155-900 Rev. F · 8/09 37 10 Installing Vent Pipe (DVP Pipe) A. Assemble Vent Sections To attach the first vent component to the starting collars of the appliance: · Lock the vent components into place by sliding the pipe section onto the collar. · Align the seam of the pipe and seam of collar to allow engagement. Rotate the vent component to lock into place. Use this procedure for all vent components. · Slide the gasket over the first vent section and place it flush to the appliance. This will prevent cold air infiltration. High temperature caulk may be used to hold the part in place. · Continue adding vent components, locking each succeeding component into place. · Ensure that each succeeding vent component is securely fitted and locked into the preceding component. Commercial, Multi-family (Multi-level exceeding two stories), or High-Rise Applications For Installation into a commercial, multi-family (multi-level exceeding two stories) or high-rise applications: All outer pipe joints must be sealed with high temperature silicone, including the slip section that connects directly to the horizontal termination cap. [. . . ] F · 8/09 71 Service Parts Service Parts Diagram RED40 Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ Granite -- No Media 6 5 6 4 3 6 3 3 5 4 2 1 2 3 1 2 Porcelain -- No Media 6 2 4 5 2 1 ITEM DESCRIPTION COMMENTS PART NUMBER Refractory Kit 1 2 3 4 5 6 Outer Bottom Panel Bottom Front Panel (Qty 3 req) Bottom Back Panel (Qty 3 req) Front Corner Panel (Qty 2 req) ITEM DESCRIPTION COMMENTS PART NUMBER Refractory Kit 1 2 3 4 5 6 Front Corner Panel (Qty 2 req) GR40-F 2155-217 2155-215 2155-216 2155-235 2155-210 2155-209 POR40-F 2155-230 2155-223 2155-226 2155-224 2155-225 2155-222 Panel Side (Qty 2 req) Outer Bottom Panel Bottom Front Panel Bottom Back Panel Back Panel Panel Side (Qty 2 req) Back Panel (Qty 3 req) Granite -- With Media 3 2 3 1 2 Porcelain -- With Media 3 3 1 2 1 1 2 ITEM 1 2 3 72 DESCRIPTION Refractory Kit Side Panel (Qty 2 req) Panel Side (Qty 2 req) Back Panel (Qty 3 req) PART NUMBER GR40-L 2175-225 2155-210 2155-209 ITEM 1 2 3 DESCRIPTION Refractory Kit Side Panel (Qty 2 req) Panel Side (Qty 2 req) Back Panel PART NUMBER POR40-L 2155-223 2155-219 2155-222 Heat & Glo · RED40, RED40ST · 2155-900 Rev. F · 8/09 Service Parts Service Parts Diagram RED40ST Beginning Manufacturing Date: May 2009 Ending Manufacturing Date: ______ 1 4 5 2 6 3 7 8 11 10 9 Base Pan -- No Media Option CB D E A Base Pan -- Media Option A B C D E F G F G Part number list on following page. Heat & Glo · RED40, RED40ST · 2155-900 Rev. F · 8/09 73 Service Parts List IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HEAT AND GLO RED40ST

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HEAT AND GLO RED40ST will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag