User manual HEAT AND GLO ST-550TM-IPI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HEAT AND GLO ST-550TM-IPI. We hope that this HEAT AND GLO ST-550TM-IPI user guide will be useful to you.

Lastmanuals help download the user guide HEAT AND GLO ST-550TM-IPI.


Mode d'emploi HEAT AND GLO ST-550TM-IPI
Download
Manual abstract: user guide HEAT AND GLO ST-550TM-IPI

Detailed instructions for use are in the User's Guide.

[. . . ] Owner's Manual Installation and Operation Models: ST-550TM-IPI NOTICE DO NOT DISCARD THIS MANUAL · Important operating and maintenance instructions included. · Read, understand and follow these instructions for safe installation and operation. · Leave this manual with party responsible for use and operation. D DI O N SC OT AR D WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. · DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. [. . . ] D · 4/09 29 Two Elbows V1 Minimum 1 ft. 305 mm 610 mm 915 mm 1. 2 m 1. 5 m H Maximum 2 ft. 610 mm 914 mm 1. 5 m 2. 1 m 4. 6 m V2 * * * * * V1 + V2 Min. * * * * * V2 H Max. (12. 2 m) * No specific restrictions on this value EXCEPT V1 + V2 + H cannot exceed 40 ft. (12. 2 m) Note: A section of vertical pipe (12 inches minimum) MUST be installed prior to attaching a 90° elbow. V1 H1 Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7. 3). Figure 7. 9 Three Elbows V1 Minimum 1 ft. 305 mm 610 mm 915 mm 1. 2 m 1. 5 m H Maximum 1 ft. 305 mm 610 mm 1. 2 m 1. 8 m 4. 3 m V2 * * * * * V1 + V2 Min. * * * * * V2 H MAX. (12. 2 m) * No specific restrictions on this value EXCEPT V1 + V2 + H1 + H2 cannot exceed 40 ft. (12. 2 m) Note: A section of vertical pipe (12 inches minimum) MUST be installed prior to attaching a 90° elbow. H1 H2 V1 Note: There MUST be a 25% reduction in total H when using flex vent except when using the simple up and out installation (see Figure 7. 3). INSTALLED HORIZONTALLY Figure 7. 10 30 Heat & Glo · ST-550TM-IPI · 2142-900 Rev. D · 4/09 8 Vent Clearances and Framing B. Wall Penetration Framing Combustible Wall Penetration Whenever a combustible wall is penetrated, you must frame a hole for the wall shield firestop(s). The wall shield firestop maintains minimum clearances and prevents cold air infiltration. · The opening must be framed on all four sides using the same size framing materials as those used in the wall construction. · SLP pipe - A wall shield firestop must be placed on each side of an interior wall. (38 mm) overlap of attached heat shields must be maintained. for information for regarding the installation of a horizontal termination cap. Non-Combustible Wall Penetration If the hole being penetrated is surrounded by noncombustible materials such as concrete, a hole with diameter one in. Whenever a non-combustible wall is penetrated, the wall shield firestop is only required on one side and no heat shield is necessary. A. Pipe Clearances to Combustibles WARNING!DO NOT pack insulation or other combustibles: · Between ceiling firestops · Between wall shield firestops · Around vent system Failure to keep insulation or other material away from vent pipe may cause over heating and fire. Note: Heat shields MUST overlap by a minimum of 1-1/2 in. · SLP heat shield - designed to be used on a wall 4-3/8 in. · If wall thickness is less than 4-3/8 the existing heat shields must be field trimmed. [. . . ] (102 mm) the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (384 mm) Term Cap Minimum Effective Length 3-1/8 in. Maximum Effective Length 4-3/4 in. (305 mm) SLP-TRAP Horizontal Termination Cap Max Effective Length Trap1 79 mm 5-1/4 in. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HEAT AND GLO ST-550TM-IPI

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HEAT AND GLO ST-550TM-IPI will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag