User manual HEIDENHAIN ND 287 8-2010

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HEIDENHAIN ND 287. We hope that this HEIDENHAIN ND 287 user guide will be useful to you.

Lastmanuals help download the user guide HEIDENHAIN ND 287.


Mode d'emploi HEIDENHAIN ND 287
Download

You may also download the following manuals related to this product:

   HEIDENHAIN ND 287 QUICK REFERENCE GUIDE (2555 ko)

Manual abstract: user guide HEIDENHAIN ND 2878-2010

Detailed instructions for use are in the User's Guide.

[. . . ] Operating Instructions ND 287 English (en) 8/2010 ND 287 Screen 1 2 3 4 5 ND 287 Front Panel 7 6 Controls and Displays 1 Status bar Current operating mode: Actual Value, Distance-To-Go. Current display mode for input X1, X2 or coupled axes X1:X2. SCL shown in black: Scaling factor is active. COMP shown in black: Error compensation or axis-error compensation is active for the currently displayed axis or coupled axes. [. . . ] If the measured value falls below or exceeds the control limits during statistical process control, the ND 287 displays a warning and switches the display to the respective control chart. If a measured value falls below or exceeds the defined tolerance limits, the ND displays the appropriate sorting symbols and the display value in red if you have activated this display color. Pin 17 or pin 18 at D-sub connection X41 are active. When you press START SPC, the ND 287 automatically resumes measured-value recording for the SPC that was last active. The previously measured sample values are retained in the FIFO memory. The memory is only cleared if you change the SPC settings in the SAMPLES or TOLERANCES form, or if you delete the measured values with the DELETE STATISTIC parameter (see "Deleting SPC statistics" on page 56). A new SPC cannot be started until the current SPC has been completed and the measured values recorded have been deleted (see "Deleting SPC statistics" on page 56). 56 I Working with the ND 287 Position Display Unit The measured values and the data of the diagrams and control charts always apply to the currently active display mode (see "Axis display mode" on page 27): In display mode X1, the SPC data applies to the encoder at input X1. In display mode X2, the SPC data applies to the encoder at input X2. In display mode X1:X2, the SPC data applies to the defined coupled position value (X1+X2, X1-X2 or f(X1, X2). Select the first soft-key page of the standard screen. Press the START SPC soft key to start the SPC function. SERIES soft key is displayed on the screen, press the MEAS. SERIES [SPC] soft key to open the SERIES OF MEASUREMENTS menu, and then press the MEAS. SERIES [SPC] soft key to switch to the SPC mode (see "Switching between series of measurements and SPC mode" on page 42). The sample counter x y/z counter is shown on the left side of the message line e. g. x is the number of the measurement that is currently being performed for the current sample, y is the number of measurements that have been recorded so far, and z is the total number of measurements that has been entered. You can switch to an analysis of the current SPC at any time by pressing the SPC ANALYSIS soft key in order to analyze the measured values recorded so far (see "SPC analysis" on page 49). VALUE soft key to delete the measured value that was last recorded. Press the ENTER key to confirm, or press the C key to cancel. You can stop the current statistical process control at any time by pressing the STOP SPC key, and you can restart it at a later time. Fig. I. 63 Standard screen with soft-key page 1 All parameters required for statistical process control and the possibility of analyzing a previously recorded SPC are provided by the SPC menu. I. 64 SPC has been started ND 287 57 I ­ 5 Series of Measurements and Statistical Process Control I ­ 6 Sorting and Tolerance Checking I ­ 6 Sorting and Tolerance Checking Sorting function To sort the parts, the ND 287 compares the displayed value with an upper or lower sorting limit, and displays the sorting result in color as a display value and with the appropriate sorting symbol in the status display: Green symbol: = Values that are displayed in green are within the sorting limits. Red symbol: < or > Values that are displayed in red are smaller than the defined lower sorting limit or greater than the defined upper sorting limit. [. . . ] 30 VA The encoder fulfills the requirements for electromagnetic compatibility according to 2004/108/EEC with respect to the generic standards for Noise immunity (IEC 61000-6-2) Emission (IEC 61000-6-4) Operating temperature Storage temperature Relative air humidity Protection (IEC 60529) Weight Housing Housing dimensions 0 °C to 50 °C (32 °F to 122 °F) ­40 °C to 85 °C (­40 °F to 185 °F) Annual mean: < 75% In exceptional cases: < 90% IP 40 rear panel, IP 54 front panel Approx. 2. 5 kg (5. 5 lb. ) Benchtop design, cast-metal housing Width: 211 mm, height: 112 mm (including feet), depth: 251 mm (including connector) Main power input Line fuse Power Electromagnetic compatibility/ CE compliance ND 287 137 II ­ 8 Specifications II ­ 9 Dimensions II ­ 9 Dimensions ND 287 Dimensions in mm HEIDENHAIN Front view with dimensions Side view with dimensions Dimensions in mm Bottom view with dimensions Tolerancing ISO 8015 ISO 2768 - m H < 6 mm: ±0. 2 mm 138 II Installation, Specifications II ­ 10 Accessories ID numbers for accessories ID number 654017-01 654018-01 654019-01 654020-01 366964-xx 354770-xx Accessories Encoder module, packaged Analog module, packaged Ethernet module, packaged Mounting base for installation in a 19-inch electrical cabinet, packaged Data transfer cable for RS-232-C/V. 24 interface, packaged Data transfer cable for USB interface, packaged ND 287 139 II ­ 10 Accessories II ­ 10 Accessories Mounting the input assemblies Danger to the operator and internal components! Do not mount the input assembly while the unit is under power! Disengage the power plug before opening the unit! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HEIDENHAIN ND 287

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HEIDENHAIN ND 287 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag