Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HERKULES G375. We hope that this HERKULES G375 user guide will be useful to you.
Lastmanuals help download the user guide HERKULES G375.
Detailed instructions for use are in the User's Guide.
[. . . ] Use the equipment only for its intended use. Do not exceed the maximum working pressure of the lowest rated system component. Do not operate the gun washer at a pressure above the maximum working pressure rating of the gun(s) being cleaned. Route the hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. [. . . ] Pipe and dispose of the exhaust air safely. If diaphragm fails, the fluid may be exhausted along with the air.
Page 4 of 13
Model Information
B C
A
D
NOTE: Dimensions listed are overall measurements.
Model
Description
Two independently operating stainless steel tanks clean
Weight lbs/(kg)
110 (49. 9)
A
42. 75 (1086)
Dimensions in. /(mm) B C
15. 5 (394) 16. 88 (429)
D
41. 5 (1054)
G375
up to 4 guns and 4 cups simultaneously with two independent diaphragm pumps.
Installation
Installing the Gun Washer
1) Place gun washer on a level surface in a properly ventilated paint mixing room or paint booth.
Grounding the Gun Washer
1) Connect the ground wire on the gun washer's pump to a true earth ground. Ground all equipment used or located in the gun washer area.
2)
Connecting the Air Line
1) Install a 1/4 in. npt male coupler, that is compatible with the quick disconnect of your air supply line, into the air supply port of the filter/regulator located on the right leg (see fig. 2). Connect air line with at least 75 psi to the coupler. Do not adjust.
Air supply port
2)
fig. 2
Page 5 of 13
Operation
Connecting the Solvent to the Washer
1) Insert the drain pipe and siphon tube into a fresh 5 gallon solvent can and secure the plug in the opening. The can must contain at least 2. 5 gallons of solvent to pump properly. Use a high quality solvent.
Placing Equipment in the Gun Washer
To clean guns not mentioned here, use the long or short stem supports as needed (see pg. 11). For questions or adapter kits contact your paint gun washer distributor. Siphon Feed Guns Place the gun siphon tube on the short stem support. Gravity Feed Guns (HVLP) Place the long stem support over the short stem support. Place paint inlet of gun on long stem support. Place the air cap assembly over the air inlet of the gun to prevent solvent from entering the passage. Pressure Feed Guns Place long stem support over the short stem support. Place paint inlet of gun on long stem support. Pots and Cups Place a pot or a cup on the cup holder.
2)
Preparing the Equipment to be washed
1) Remove paint cup or paint line and the air line from the paint gun. Remove all gauges and regulators from painting equipment. Lock the gun trigger in the open position by placing the trigger lock around the gun handle and trigger (see fig. 3).
2) 3) 4)
CAUTION
All pressure gauges must be removed before placing the equipment in the gun washer to avoid damaging the gauges.
Siphon Feed Gun
Gravity Feed Gun (HVLP)
Air Cap Assembly Long Stem Support
Paint Cup
Paint Cup Cup Holder Trigger Lock
Paint Cup
Pressure Feed Gun
Short Stem Support
Note: Only one gun & one cup shown for clarity. G375 will clean two guns & two cups in each tank simultaneously.
fig. 3
Page 6 of 13
Operation
Operating the Gun Washer
1) Make sure wire trigger locks and other accessories are inside the gun washer tank. Place equipment in the tank according to the diagrams shown in fig. 3. Close the gun washer lid.
Gun Washer Information
1) The two tanks of the gun washer can be operated independently. The timer on the right leg operates the pump for the right tank, while the timer on the left leg operates the pump for the left tank.
2)
2)
3) 4)
Operating the Manual Brush
Turn the timer knob clockwise 90 degrees to start the gun washer. [. . . ] Make sure the air line is properly connected with at least 75 psi. Check all air connections to ensure that there are no leaks. Make sure there is 5 gallons of clean solution in the gun washer. The cleaning solution should be an inch above the intake filter. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HERKULES G375
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HERKULES G375 will begin.