[. . . ] Specifications
Type of Unit Duct Mounting GPD @ 140 ° F GPD @ 120 ° F GPD @ 100 ° F Voltage Unit Dimensions Duct Opening Standard Equipment Rotating Drum Return 22. 5 16. 5 10. 6 24V 14 3/4" W x 11" D x 11 1/2" H 4 5/8" x 7 5/8" Wall / duct mount humidistat Self piercing saddle valve 7" Flange & Damper Features · Externally held evaporative media · Independent mounting bracket · Right or left hand discharge without disassembly · All brass valve assembly · Stainless steel cage · Observation window in front door · 2 year warranty Supply 17. 1 12. 4 7. 8
Capacity Selection Guide Sq. Footage Tight Home Average Home Loose Home of Home (GPD*) (GPD*) (GPD*) 1000 1500 2000 2500 3000 4000 0. 5 3. 0 5. 0 7. 5 10. 0 14. 5 5. 0 10. 0 14. 0 19. 0 23. 5 33. 0 10. 0 16. 5 24. 0 30. 5 37. 5 51. 5
The above calculations are for reference only and are based on the following: · Inside temperature 70° F/35% relative humidity · Outside Temp 20° F /70% relative humidity · 8 foot ceiling height · Internal moisture gain of one pound per hour · Furnace on-time of 70% This chart uses A. R. I. standard designations: A "Tight Home" is assumed to be well insulated with vapor barriers, tight storm windows and doors, and a dampered fireplace. Air exchange rate of . 50 changes per hour. [. . . ] The water level should be 1 3/8" below the bottom edge of the 5 1/2" diameter bypass duct opening. If necessary, adjust the float/rod assembly to provide the correct water level. When installing this humidifier above electric warm air heating elements or where water damage could occur from accidental overflow, connect a 1/2" drain hose to the brass overflow nipple. Do NOT solder the drain line directly to the humidifier because heat can warp and damage the pan. Mount the Increaser to the unit by inserting the small end of the Increaser into the open end of the unit and securing with clamp. Attach 7" bypass flex or metal duct (not provided) to Increaser and Return Air Flange. Insert the window panel by reversing Step #1.
Bypass duct
Saddle valve assembly
Humidifier Air cleaner
Bypass duct
Air cleaner Alternate location "A" coil Humidifier Humidifier
Air cleaner Bypass duct
Air cleaner Humidifier Bypass duct Humidifier
4
Electrical Installation
This humidifier is intended to be wired independently of the integrated control panel on your furnace. This will provide power to the humidifier at all times, causing the evaporator pad drum to rotate constantly.
WARNING
Improper electrical wiring can cause personal shock, injury, or property damage. It is required by local codes that the unit be installed by a properly qualified HVAC technician or electrician, following NEC and any other local codes. Read the instructions in the furnace installation manual carefully before attempting installation or operation of this humidifier. Failure to follow these instructions may result in an improper installation and therefore, void the manufacturer's warranty.
120V HOT 120V COMMON HOUSE GROUND
FUSED FURNACE SWITCH/BLOWER OR FUSED CIRCUIT WITH INDEPENDENT WALL SWITCH PLUG-IN TRANSFORMER (NOT PROVIDED) OR INSTALLED TRANSFORMER LOW VOLTAGE (24 VAC)
HUMIDISTAT
HUMIDIFIER
1. Turn the humidistat to the highest level (past 60%) and the humidifier should begin to run. The humidifier should stop when the humidistat is turned off. Set the furnace controls and humidistat for the desired conditions (30-40% RH is recommended). Operation of this unit is automatic.
5
Operation
This 465-C1 humidifier operates on the silent principle of evaporation. When your unit is operating properly, you may observe the drum turning freely by looking through the observation window. Evaporation takes place as the air passes through the moistened evaporator pad held in place by the specially engineered rotating drum assembly. Working in conjunction with the heating system blower, a portion of the warm air is bypassed through the humidifier for quiet and economical humidification of the air in your home. The humidifier is designed for use with either hard or softened water. Set the humidistat in the recommended range of 30-50% Relative Humidity for automatic humidity control during the heating season (a lower setting may be used to control condensation on single pane windows). During the first heating season, check for mineral build-up on the evaporator pad every month to establish the proper cleaning schedule. Clean the unit at the end of each heating season or whenever mineral deposits appear to clog the openings in the evaporator pad You can easily check your humidifier to be sure it is in working condition. [. . . ] There is no warranty due to neglect, alteration or ordinary wear and tear. Herrmidifier's liability is limited to replacement of defective parts or components and does not include the payment of the cost of labor charges to remove or replace such defective components or parts. CareCo will not be responsible for loss of use of any product; loss of time, inconvenience, or any other indirect, incidental or consequential damages with respect to person or property, whether as a result of breach of warranty, neglect or otherwise. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HERRMIDIFIER 465-C1
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.