User manual HITACHI DESKSTAR P7K500 MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HITACHI DESKSTAR P7K500. We hope that this HITACHI DESKSTAR P7K500 user guide will be useful to you.

Lastmanuals help download the user guide HITACHI DESKSTAR P7K500.


Mode d'emploi HITACHI DESKSTAR P7K500
Download

You may also download the following manuals related to this product:

   HITACHI DESKSTAR P7K500 DATASHEET (462 ko)
   HITACHI DESKSTAR P7K500 INSTALLATION GUIDE (162 ko)

Manual abstract: user guide HITACHI DESKSTAR P7K500MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Hitachi Global Storage Technologies Hard Disk Drive Specification Hitachi Deskstar P7K500 Hitachi CinemaStar P7K500 3. 5 inch hard disk drive Models: HDP725016GLAT80 HDP725016GLA380 HDP725025GLAT80 HDP725025GLA380/1 HDP725032GLAT80 HDP725032GLA380 HDP725032GLA360/1 HDP725040GLAT80 HDP725040GLA380 HDP725040GLA360/1 HDP725050GLAT80 HDP725050GLA380 HDP725050GLA360/1 HCP725016GLAT80 HCP725016GLA380 HCP725025GLAT80 HCP725025GLA380 HCP725032GLAT80 HCP725032GLA380 HCP725050GLAT80 HCP725050GLA380 Revision 1. 0 (November 14, 2007) The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with local law: HITACHI GLOBAL STORAGE TECHNOLOGIES Inc. PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer or express or implied warranties in certain transactions, therefore, this statement may not apply to you. This publication could include technical inaccuracies or typographical errors. [. . . ] The device timeout values are described in the Section 11. 0 on the page 266. 9. 1 PIO Data In commands Device Configuration Identify Identify Device Read Buffer Read Log Ext Read Multiple Read Multiple Ext Read Sector(s) Read Sector(s) Ext Read Stream PIO SMART Read Attribute Values SMART Read Attribute Thresholds SMART Read Log Sector These commands are: Execution includes the transfer of one or more 512 byte sectors of data from the device to the host. 9. 2 PIO Data Out commands These commands are: Device Configuration Set Download Microcode Format Track Security Disable Password Security Erase Unit Security Set Password Security Unlock Set Max Set Password command Set Max Unlock command SMART Write Log Sector Write Buffer Write Log Ext Write Multiple Write Multiple Ext HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 111 Write Multiple FUA Ext Write Sector(s) Write Sector(s) Ext Write Stream PIO Execution includes the transfer of one or more 512 byte sectors of data from the host to the device. 9. 3 Non-Data commands Check Power Mode Configure Stream Device Configuration Freeze Lock Device Configuration Restore Execute Device Diagnostic Flush Cache Flush Cache Ext Idle Idle Immediate Initialize Device Parameters NOP Read Native Max Address Read Native Max Address Ext Read Verify Sector(s) Read Verify Sector(s) Ext Recalibrate Security Erase Prepare Security Freeze Lock Seek Set Features Set Max Address Set Max Address Ext Set Max Lock command Set Max Freeze Lock command Set Multiple Mode Sleep SMART Disable Operations SMART Enable/Disable Attribute Autosave SMART Enable Operations SMART Execute Off-line Data Collection SMART Return Status SMART Save Attribute Values SMART Enable/Disable Automatic Off-Line Standby Standby Immediate Write Uncorrectable Ext These commands are: Execution of these commands involves no data transfer. 9. 4 DMA Data In commands and DMA Data Out commands These commands are: Read DMA Read DMA Ext Read Stream DMA Write DMA Write DMA Ext Write DMA FUA Ext Write Stream DMA Execution of this class of command includes the transfer of one or more blocks of data between the device and HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 112 the host using DMA transfer. 9. 5 First-party DMA commands Read FPDMA Queued Write FPDMA Queued These commands are: Execution of this class of commands includes command queuing and the transfer of one or more blocks of data between the device and the host. The protocol is described in the section 4. 2 "Native Command Queuing" of "Serial ATA II: Extensions to Serial ATA 1. 0a". Host knowledge of I/O priority may be transmitted to the device as part of the command. There are two priority classes for NCQ command as high priority, the host is requesting a better quality of service for that command than the commands issued with normal priority. The device may choose to complete a normal priority command before an outstanding high priority command, although preference shallbe given to the high priority commands. The priority class is indicated in bit 7 (Priority Information) in the Sector Count register for NCQ commands (READ FPDMA QUEUED and WRITE FPDMA QUEUED). This bit can indicate either the normal priority or high priority class. If a command is marked by the host as high priority, the device shall attempt to provide better quality of service for the command. It is not required that devices process all high priority requests before satisfying normal priority requests. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 113 HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 114 10. 0 Protocol 3 3 3 3 3 1 2 2 3 3 3 2 1 3 3 3 3 3 1 4 4 4 5 1 1 1 3 3 1 1 1 4 4 3 3 3 3 2 3 2 3 2 2 Table 79 Command Descriptions Command Check Power Mode Check Power Mode* Configure Stream Device Configuration Restore Device Configuration Freeze Lock Device Configuration Identify Device Configuration Set Download Microcode Execute Device Diagnostic Flush Cache Flush Cache Ext Format Track Identify Device Idle Idle* Idle Immediate Idle Immediate* Initialize Device Parameters Read Buffer Read DMA Read DMA Read DMA Ext Read FPDMA Queued Read Log Ext Read Multiple Read Multiple Ext Read Native Max Address Read Native Max Address Ext Read Sector(s) Read Sector(s) Read Sector(s) Ext Read Stream DMA Read Stream PIO Read Verify Sector(s) Read Verify Sector(s) Read Verify Sector(s) Ext Recalibrate Security Disable Password Security Erase Prepare Security Erase Unit Security Freeze Lock Security Set Password Security Unlock Command Set Code (Hex) E5 98 51 B1 B1 B1 B1 92 90 E7 EA 50 EC E3 97 E1 95 91 E4 C8 C9 25 60 2F C4 29 F8 27 20 21 24 2A 2B 40 41 42 1x F6 F3 F4 F5 F1 F2 7 1 1 0 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 6 1 0 1 0 0 0 0 0 0 1 1 1 1 1 0 1 0 0 1 1 1 0 1 0 1 0 1 0 0 0 0 0 0 1 1 1 0 1 1 1 1 1 1 Binary Code Bit 5 1 0 0 1 1 1 1 0 0 1 1 0 1 1 0 1 0 0 1 0 0 1 1 1 0 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 1 1 4 0 1 1 1 1 1 1 1 1 0 0 1 0 0 1 0 1 1 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 3 0 1 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 1 1 0 0 1 0 1 1 0 0 0 0 1 1 0 0 0 1 0 0 0 0 0 2 1 0 0 0 0 0 0 0 0 1 0 0 1 0 1 0 1 0 1 0 0 1 0 1 1 0 0 1 0 0 1 0 0 0 0 0 0 0 1 1 0 0 1 0 0 0 0 0 0 0 1 0 1 1 0 0 1 1 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 0 1 1 0 0 1 1 1 0 0 0 1 0 1 0 1 1 1 1 1 0 0 1 0 0 0 1 1 1 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 0 0 0 1 0 0 1 0 1 1 0 HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 115 Protocol 3 3 3 3 3 3 3 3 3 3 3 1 1 3 3 2 3 3 3 3 3 2 4 4 4 4 5 2 2 2 2 2 2 2 4 4 3 Command Seek Set Features Set Max Address Set Max Address Ext Set Multiple Mode Sleep Sleep* SMART Disable Operations SMART Enable/Disable Attribute Auto save SMART Enable Operations SMART Execute Off-line Data Collection SMART Read Attribute Values SMART Read Attribute Thresholds SMART Return Status SMART Save Attribute Values SMART Write Log Sector SMART Enable/Disable Automatic Off-line Standby Standby* Standby Immediate Standby Immediate* Write Buffer Write DMA Write DMA Write DMA Ext Write DMA FUA Ext Write FPDMA Queued Write Log Ext Write Multiple Write Multiple Ext Write Multiple FUA Ext Write Sector(s) Write Sector(s) Write Sector(s) Ext Write Stream DMA Write Stream PIO Write Uncorrectable Ext 1: 2: 3: 4: 5: +: Command Set --Continued-Protocol : Code (Hex) 7x EF F9 37 C6 E6 99 B0 B0 B0 B0 B0 B0 B0 B0 B0 B0 E2 96 E0 94 E8 CA CB 35 3D 61 3F C5 39 CE 30 31 34 3A 3B 45 7 0 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1 0 1 0 0 0 0 0 0 6 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 1 1 0 0 1 0 1 0 1 0 0 0 0 0 1 Binary Code Bit 5 4 3 2 1 1 1 0 1 1 1 1 1 0 1 1 0 1 0 0 0 1 1 0 0 1 0 1 1 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 0 0 0 0 1 0 1 1 0 0 0 0 1 0 1 1 0 1 0 0 0 1 0 0 0 1 0 1 1 0 1 1 1 1 1 1 0 0 0 1 1 1 1 0 0 0 1 1 1 1 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 1 1 1 0 1 1 1 0 0 0 0 1 1 1 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 1 1 0 0 0 1 0 0 1 0 0 0 1 1 0 0 1 1 1 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 0 0 1 0 0 1 1 PIO data IN command PIO data OUT command Non data command DMA command Vendor specific command Table 80 Commands marked * are alternate command codes for previous defined commands. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 116 Command (Subcommand) (SMART Function) SMART Read Attribute Values SMART Read Attribute Thresholds SMART Enable/Disable Attribute Autosave SMART Save Attribute Values SMART Execute Off-line Data Collection SMART Read Log SMART Write Log SMART Enable Operations SMART Disable Operations SMART Return Status SMART Enable/Disable Automatic Off-line (Set Features) Enable Write Cache Set Transfer Mode Enable Advanced Power Management Enable Power-up in Standby Feature Set Power-up in Standby Feature Set Device Spin-up Enable Address Offset Mode Enable Automatic Acoustic Management Disable read look-ahead feature Disable reverting to power on defaults Disable write cache Disable Advanced Power Management Disable Power-up in Standby Feature Set Disable Address Offset Mode Enable read look-ahead feature Disable Automatic Acoustic Management Enable reverting to power on defaults Table 81 Command Set (Subcommand) Command code (Hex) Feature Register (Hex) D0 D1 D2 D3 D4 D5 D6 D8 D9 DA DB 02 03 05 06 07 09 42 55 66 82 85 86 89 AA C2 CC B0 B0 B0 B0 B0 B0 B0 B0 B0 B0 B0 EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF EF Table 78 Command Set on page 115 and Table 79 Command Set --Continued-- on page 116 show the commands that are supported by the device. Table 80 on page 117 shows the sub-commands those are supported by each command or feature. HITACHI Deskstar & CinemaStar P7K500 Hard Disk Drive specification (Rev 1. 1) 117 The following symbols are used in the command descriptions: Output Registers 0 Indicates that the bit must be set to 0. 1 Indicates that the bit must be set to 1. Indicates that the device number bit of the Device/Head Register should be specified. This bit is reserved since all Serial ATA devices behave like Device 0. Indicates that the head number part of the Device/Head Register is an output parameter and should be specified. Zero specifies CHS mode and one does LBA addressing mode. Original meaning is already obsoleted, there is no difference between 0 and 1. (Using 0 is recommended for future compatibility. ) Option Bit. Indicates that the Option Bit of the Sector Count Register should be specified. (This bit is used by Set Max ADDRESS command) V Valid. Indicates that the bit is part of an output parameter and should be specified. x Indicates that the hex character is not used. Input Registers 0 Indicates that the bit is always set to 0. [. . . ] In this case read commands and/or write commands shall return ERR status information that is consistent with the error. If the LOG feature is set to x5h sectors that have been made pseudo uncorrectable when read back shall be listed as failed in the standard error logs and shall cause SMART utilities to indicate failure if too many sectors are uncorrectable. The LOG feature set to xAh shall indicate that reading of pseudo uncorrectable sectors shall not be logged as an error in any standardized error logs. The pseudo uncorrectable or flagged uncorrectable status of a sector shall remain through a power cycle. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HITACHI DESKSTAR P7K500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HITACHI DESKSTAR P7K500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag