Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HITACHI SJ-EN. We hope that this HITACHI SJ-EN user guide will be useful to you.
Lastmanuals help download the user guide HITACHI SJ-EN.
Detailed instructions for use are in the User's Guide.
[. . . ] The SJ-EN uses the open MODBUS/TCP communication protocol. It utilizes a 10Base-T physical interface with a 10 Mbps data transfer rate. Even though the board uses the MODBUS/TCP, this does not necessarily mean that all MODBUS services and functions are supported. Detailed description of the available functionality is provided in Chapter 4 of this manual. [. . . ] CAUTION: When configuring parameters with the standard keypad, the inverter checks for and inhibits invalid parameter combinations when the STR key is pressed. The SJ-EN bypasses this check, so it is incumbent on the user to make sure invalid configuration parameters or combinations are not sent through network commands. Otherwise undesirable inverter behavior may occur. CAUTION: Certain parameter data ranges vary depending on model and capacity. The SJ-EN does NOT check to make sure these data are within range. It is incumbent on the user to make sure data for these parameters is within range for the specific model and rating. These parameters are noted in the parameter tables in the Appendix. Otherwise undesirable inverter behavior may occur.
INVERTER COMPATIBILITY
The inverter firmware revision number is embedded within the inverter Manufacturing Number, which can be found on the product nameplate. The SJ-EN Ethernet Interface option board is compatible only with SJ300 and L300P series inverters with Revision Numbers HIGHER than those shown below. XX8KT XXXXX XXXXX for SJ300-xxxXFU 0. 4 kW (0. 5 hp) to 55 kW (75 hp), or L300P-xxxXFU or L300P-xxxXBRM 1. 5 kW (2 hp) to 75 kW (100 hp) XXEMT XXXXX XXXXX for SJ300-xxxXFU 75kW (100 hp) to 150 kW (200 hp), or L300P-xxxXFU or L300P-xxxXBRM 90 kW (125 hp) to 132 kW (175 hp)
Note: All inverters in the model number series L300P-xxxXFU2 are compatible with the SJ-EN, regardless of revision number.
Page 7 of 38
Chapter 1
NOTES:
Page 8 of 38
Chapter 2
Chapter 2 Installation and Wiring
Orientation to Product Features
Figure 2-1 below shows the physical layout of the SJ-EN Ethernet option board. In particular, note the location of status LEDs and DIP-switches.
STATUS LEDs · · · · STATUS LINK ACTIVITY ERROR
RJ45 Jack
76543210 ON
Connector to connect to SJ300 or L300P (rear of board)
RXD LED
SJ-EN
DIP Switches
OFF
TXD LED
Figure 2-1 SJ-EN Layout
The pinout for the RJ45 connector is as follows: 1. TX Data + TX Data RX Data + NC NC RX Data NC NC
8
7
6
5
4
3
2
1
Figure 2-2 SJ-EN RJ45 Pinouts
Page 9 of 38
Chapter 2
Installing the Option Board
Power down the inverter and wait at least five minutes before moving to the next step. Open and remove the lower terminal cover. Confirm that the red CHARGE LED is extinguished and that the DC bus is fully discharged before proceeding further, otherwise there is the danger of electric shock. You can now remove the upper front cover to expose the two option ports inside. Figure 2-3 below shows how to install the option board to option port 1 or 2 of the inverter. There are four holes on the corners of the option board. Align the board with the port connector in the proper orientation (to the left, when facing the inverter as show). Then align the top two holes with the two screw holes, and the bottom two holes with the two guide posts. Insert the board fully into the connector. Secure the board with the two M3 screws supplied.
Option board
Guide posts for option board positioning
Option port 1 Option port 2
Screw holes for securing the option board (M3 screws x 2)
Figure 2-3 Installation of SJ-EN
Page 10 of 38
Chapter 2 User Interface
The SJ-EN has six LEDs to convey module status and activity. Four LEDs next to the RJ45 connector:
· STATUS (GREEN) This LED will be ON whenever the SJ-EN is receiving proper power from the inverter and the self diagnostics have shown the board to be functioning normally. [. . . ] These will give valuable clues to the nature of the problem. In addition, the inverter operator/keypad will provide diagnostic information for certain types of errors. Error codes for the option boards will have the format of:
E6X. X for a board installed in option slot 1, or E7X. X for a board installed in option slot 2. The number
to the right of the decimal point indicates the drive status at the time of trip, as follows:
EXX. 0 EXX. 3 EXX. 6
At reset At constant speed At starting
EXX. 1 EXX. 4 EXX. 7
At stop During acceleration During DC injection braking
EXX. 2 EXX. 5 EXX. 8
During deceleration f0 Stop During overload restriction
The digit immediately to the left of the decimal point has the following meaning:
Code Trip Name Cause Check Remedy
Defective connection
Connectors (plugs & jacks), cable That PC is powered on and connected Verify proper Ethernet setup of SJ-EN and master device
Replace or repair; press STOP/RESET on inverter keypad Press STOP/RESET on inverter keypad
EX0. X
Ethernet Communication Error
PC not powered up or not connected to inverter Network configuration error
Reconfigure incorrect settings.
EX9. X
Internal Communication Error (between SJ-EN and inverter)
Verify board is Option board ajar or properly seated in loose connector Board lockup Board defective Check status LEDs Check status LEDs Inverter Manufacturing Number for version (see Page 7)
Remove and reseat board Press STOP/RESET key on inverter or cycle power Replace SJ-EN Replace Inverter with later version
Inverter Mismatch (blinking display as shown)
Inverter firmware version not compatible with SJ-EN option board
Page 19 of 38
Appendix
NOTES:
Page 20 of 38
Appendix
Appendix Parameter List
Note: Parameters in BOLDFACE can be edited while inverter is in the RUN mode. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HITACHI SJ-EN
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.