If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL CM900 WIRELESS. We hope that this HONEYWELL CM900 WIRELESS user guide will be useful to you.
Lastmanuals help download the user guide HONEYWELL CM900 WIRELESS.
Manual abstract: user guide HONEYWELL CM900 WIRELESSINSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] DRAWING DETAILS
PART NUMBER ISS ECO AND DATE
42011076-003
R2
0024168 08/06
DRAWN MKTING DATE
ARTWORK DESCRIPTION CM900 RF INSTALLATION GUIDE (UK - English)
MF
BM
08/06
SIZE AND FOLDING
A3 SIZE WHEN PRINTED SIZE WHEN FOLDED A4 A5 x A6 x A7 OTHER BOOKLET
MATERIAL
CARTRIDGE MATT ART x WEIGHT 70g x 80g 100g 115g 150g OTHER
PRINTING
SINGLE SIDE DOUBLE SIDE
ONECOLOUR TWOCOLOUR THREECOLOUR FULLCOLOUR
x
x
BLACK
SEE FOLLOWING PAGES FOR COLOUR DESIGNATION. ALL PRINTING MUST BE CLEAR, FREE OF SMUDGES AND MULTI COLOUR PRINT PROPERLY REGISTERED
SPECIAL INSTRUCTIONS
Folding Sequence Finished Size
148mm
105mm
CM900 RF Installation Guide
xxxxxxxxxx
Part Number
Front
12 page A5 saddle stitched booklet folded to A6
Back
DO NOT INCLUDE THIS PAGE IN THE PRINTING
CM900 Wireless Installation Guide
CM927 / CM921 Wireless Programmable Room Thermostat & HC60NG Receiver Box
Description
The Honeywell CM900 Wireless (CM927 or CM921) is a modern wireless programmable room thermostat based on Honeywell's proven programming philosophy. To further improve the ease of use, this product includes an extra large LCD display with backlighting and LoT Technology to assist customers during daily use. The CM927/921 room thermostat communicates with the HC60NG receiver box on an 868MHz Radio Frequency (RF) band to control a single heating system component such as a boiler, pump or zone valve. [. . . ] · It is recommended that the receiver box is fully installed.
2. 3 System Check
Now a simple test can be completed to check the full system has been installed correctly: 1. Check the boiler supply is on and check that the green LED on the receiver box is off. Adjust the setpoint up to the maximum (35°C) by pressing the button. The boiler should come on (green LED ON on receiver box) after a few seconds and the symbol appears on the room thermostat LCD display. The boiler will go off (green LED OFF on receiver box) after a few seconds and the symbol disappears. Check the system operation by moving the slider between MAN and OFF modes several times, bearing in mind the switching delay referred to above. Now, you should have completed the installation successfully - to begin operating at the default factory settings move the slider to the AuTO mode or select PROG to modify the built-in heating program accordingly. Installation Guide
3) Basic Operation of the System
3. 1 Automatic Operation
The receiver box receives the heat demand (0100%) signal from the room thermostat. The room thermostat will display the symbol on the LCD display whenever more heat is required. Depending on the demand the receiver box will switch the heating device on to match the current requirements of the system. The green LED indicates the status of the relay output: · Green LED on = relay on · Green LED off = relay off
HC60NG Receiver Box
Push button and relay status LED's
3. 2 Temporary Manual Override
Pressing the receiver box button will override the current relay position. As soon as the next signal is received from the room thermostat the receiver box will return back to automatic operation as the automatic control has higher priority than manual operation.
3. 3 Communications Loss
If the RF communication is lost for a period of 1 hour the red LED will illuminate to indicate that no RF messages have been received during the last hour. The receiver box will also enter the failsafe mode as selected in Installer Mode (see section 4. 2 HC60 Receiver Box Fail-Safe Mode Setup). To allow manual control of the receiver box output manual override is available in fail-safe mode. When RF communication is restored the receiver box will automatically return to normal operation. You can now use the USER GUIDE supplied with the room thermostat to demonstrate how it works to the home owner.
4) Installer Mode
Installer Mode is used to alter the system settings for specific applications, to use the special features of the room thermostat in a different way or to alter the factory preset parameters. Parameters are divided into two groups: - Category 1 parameters Room Thermostat Setup - Category 2 parameters System Setup. These are all listed in section 4. 5 Installer Parameters Table.
CM900 Wireless - Programmable Room Thermostat
4. 1 Entering Installer Mode
1
DAY COPY DAY
2
OFF
DATE PROG AUTO MAN OFF
CM9
1. .
Move the slider switch to the OFF mode. button and the two &
The unit will display the first parameter of installer parameter group category 1 (from Parameter n. 1 to n. 19) as shown
3
Press the or to change factory setting. The display will flash indicating that a change has been made.
4
Press the green button to confirm the change. The display will stop flashing.
5
Press button to go to the next parameter.
6
Press button to go to Installer parameter group category 2 ( ) (from Parameter n. 1 to n. 14).
7
To exit the installer mode, move the slider switch to the AuTO or MAN positions.
4. 2 HC60NG Receiver Box Fail-Safe Mode Setup
The failsafe mode defines the receiver box output relay status if the RF communication is lost (e. g. when the room thermostat stops communicating due to discharged batteries). [. . . ] If the red LED still flashes push the button again until binding is successful. Now go to Section 2) Installing the CM900 Wireless System to setup the system.
5. 2 Multi-Zone System
Multiple room thermostats and receiver box sets can also be used to control multi-zone systems and the CM927/921 room thermostat is compatible with a variety of other Honeywell products including HR80 radiator controllers and HCE80 underfloor heating controllers. If you intend to use it in this way additional installation and user instructions can be obtain by contacting the address at the end of this guide. NOTE: Some of the labels supplied with the pack are for use in multizone applications.
Installation Guide
11
6) Trouble Shooting
6. 1 Trouble Shooting Guide
Symptom (Fault Message)
The room thermostat displays the symbol but the receiver box relay does not switch on. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL CM900 WIRELESS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.