Detailed instructions for use are in the User's Guide.

[. . . ] By installing a pressure reducing valve, pressurisation damage is avoided and water consumption is reduced. The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. [. . . ] The set pressure is also maintained constant, even when there is wide inlet pressure fluctuation. Reduction of the operating pressure and maintaining it at a constant level minimizes flow noise in the installation. Special Features · · · · · · Non-rising stem for setting outlet pressure and position indicator on spring bonnet (except for DN200) The adjustment spring is not in contact with the potable water With inlet and outlet pressure gauge (DN80-DN150) or with outlet pressure gauge (DN50, DN65, DN200) Inlet pressure balancing - fluctuating inlet pressure does not influence outlet pressure Powder coated inside and outside - Powder used is physiologically and toxicologically safe Reliable and proven Water, compressed air* and nitrogen* in consideration of valid standards (e. g. 16 bar 0. 2 - 2 bar Construction The pressure reducing valve comprises: · · · · · EN0H-1008GE23 R1109 · Subject to change Range of Application Medium Housing with PN16 flanges per ISO7005-2, EN1092-2 Spring bonnet with adjustment screw Adjustment spring Valve system complete with diaphragm Pressure gauge Grey cast iron housing Cast iron spring bonnet Bronze valve seat Bronze piston guide Cone up to DN150: brass, DN200: steal Spring steel adjustment spring EPDM diaphragm NBR seal collar NBR seals Stainless steel screws and nuts Inlet pressure Outlet pressure Technical Data Materials · · · · · · · · · · Operating tempera- max. 70°C ture Nominal pressure Minimum pressure drop PN16 0. 5 bar Diaphragm pressure max. DIN/DVGW tested in compulsory test sizes DN 65, DN 80 and DN 100 FY69P RV283P Strainer With double mesh, grey cast iron housing, powder coated inside and outside. A = Mesh size approximately 0. 5 mm F76S-F Reverse-rinsing filter Red bronze housing and filter bowl. Available in sizes DN 65 to DN 100, with filter mesh sizes 100 µm or 200 µm FY69P F76S-F EN0H-1008GE23 R1109 · Subject to change 48 www. honeywell. com D15P Pressure reducing valve with balanced seat Installation Example Connection size W* DN 50 mm 115 65 150 80 170 100 225 125 240 150 275 200 410 * Minimum distance from wall to centre line of pipework Installation Guidelines · · · Install in horizontal pipework with spring bonnet directed upwards Install shutoff valves The installation location should be protected against frost and be easily accessible o Pressure gauge can be read off easily o Simplified maintenance and cleaning Install downstream of the filter or strainer o This position ensures optimum protection for the pressure reducing valve against dirt Provide a straight section of pipework of at least five times the nominal valve size after the pressure reducing valve (in accordance with DIN 1988, Part 5) Typical Applications Pressure reducing valves of this type are suitable for multi dwelling buildings, industrial and commercial applications within the range of their specifications. Pressure reducing valves should be installed: · · If the static pressure exceeds the maximum permissible value for the system If several pressure zones are required when a pressurisation system is used (pressure reducers on each storey of a building) If pressure fluctuations in the downstream system must be avoided To achieve constant inlet and outlet pressures on pumped pressure boosting systems To reduce the water consumption · · · · · Flow Diagram EN0H-1008GE23 R1109 · Subject to change www. honeywell. com 49 D15P Pressure reducing valve with balanced seat Spare Parts DN50 - DN150 Pressure Reducing Valve D15P, from 2003 onwards No. 5708000 5708100 5708200 5708300 5708400 5708500 5708600 0901353 0901354 0901355 0901356 0901357 0901358 0901359 0900255 0900256 0900257 0900258 0900259 0900260 0900261 0900247 0900248 0900249 0900250 0900251 0900252 0900253 M07M-A16 M07M-A4 Diaphragm for D15PDN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 Set of seals DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 2 1 6 4 2 2 3 2 2 3 4 DN200 Guide bush with seal DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 Seat bush with seal DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 6 5 5 6 Pressure gauge Ranges 0 - 16 bar Pressure gauge Ranges 0 - 4 bar 1 4 2 2 2 2 3 Automation and Control Solutions Honeywell GmbH Hardhofweg D-74821 Mosbach Phone: (49) 6261 810 Fax: (49) 6261 81309 http://europe. hbc. honeywell. com www. honeywell. com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. [. . . ] Available in sizes DN 65 to DN 100, with filter mesh sizes 100 µm or 200 µm FY69P F76S-F EN0H-1008GE23 R1109 · Subject to change 48 www. honeywell. com D15P Pressure reducing valve with balanced seat Installation Example Connection size W* DN 50 mm 115 65 150 80 170 100 225 125 240 150 275 200 410 * Minimum distance from wall to centre line of pipework Installation Guidelines · · · Install in horizontal pipework with spring bonnet directed upwards Install shutoff valves The installation location should be protected against frost and be easily accessible o Pressure gauge can be read off easily o Simplified maintenance and cleaning Install downstream of the filter or strainer o This position ensures optimum protection for the pressure reducing valve against dirt Provide a straight section of pipework of at least five times the nominal valve size after the pressure reducing valve (in accordance with DIN 1988, Part 5) Typical Applications Pressure reducing valves of this type are suitable for multi dwelling buildings, industrial and commercial applications within the range of their specifications. Pressure reducing valves should be installed: · · If the static pressure exceeds the maximum permissible value for the system If several pressure zones are required when a pressurisation system is used (pressure reducers on each storey of a building) If pressure fluctuations in the downstream system must be avoided To achieve constant inlet and outlet pressures on pumped pressure boosting systems To reduce the water consumption · · · · · Flow Diagram EN0H-1008GE23 R1109 · Subject to change www. honeywell. com 49 D15P Pressure reducing valve with balanced seat Spare Parts DN50 - DN150 Pressure Reducing Valve D15P, from 2003 onwards No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL D15P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL D15P will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag