User manual HONEYWELL DPTM50D-5000D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL DPTM50D-5000D. We hope that this HONEYWELL DPTM50D-5000D user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL DPTM50D-5000D.


Mode d'emploi HONEYWELL DPTM50D-5000D
Download
Manual abstract: user guide HONEYWELL DPTM50D-5000D

Detailed instructions for use are in the User's Guide.

[. . . ] 3-WIRE DIFFERENTIAL PRESSURE TRANSMITTERS WITH DIGITAL DISPLAY AND CURRENT/VOLTAGE OUTPUT SPECIFICATION DATA & MOUNTING INSTRUCTIONS DPTM50D-5000D FEATURES · · · · · · · · · · · Monitoring gaseous, non-aggressive media Piezo-resistive pressure transducer Up to 40 kPa (60 kPa) overload capacity Rugged design; protection class IP54 Easy installation and wiring connection Measurement range adjustable by jumper Response time adjustable by jumper Output signal adjustable by jumper Red digital display Display of values > +1000 Pa in kPa Re-zeroing possible by pushbutton NOTE: These sensors are not suitable for use in installations under periodic inspection by the U. S. Food and Drug Administration. GENERAL The differential pressure transmitters of the DPTM series are used for measuring differential pressure, positive pressure, and vacuum. [. . . ] The pressure to be measured is applied to and thus deflects a thin membrane made of mono-silicon. The membrane's semiconductor resistors (arranged to simultaneously compensate for the temperature response) detect this mechanical deflection and generate an electrical output signal. The output signal is converted into the 0. . . 10 V or 4. . . 20 mA analog signal which changes (within the specified error limits) in proportion to the applied pressure and is shown in the LED display. NOTE: The devices are factory pre-set to pressure range 1. This can be changed (except for +/- models) to pressure range 2 by removing the corresponding jumper (see Fig. NOTE: The devices are factory pre-set to a response time of 1 second. This can be changed to 100 ms by removing the corresponding jumper (see Fig. NOTE: The devices are factory pre-set to an output signal of 0. . . 10 V. This can be changed to 4. . . 20 mA by removing the corresponding jumper (see Fig. Mounting WIRING PRESSURE RANGE jumper inserted = pressure range 1 jumper removed = pressure range 2 RESPONSE TIME jumper inserted = 1 sec jumper removed = 100 msec ACCESSORIES DPSK: Included in delivery. [. . . ] Wiring details Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative: Fema Controls Honeywell GmbH P. O. Box 1254 71099 Schönaich Germany phone: (49) 7031-637-02 fax: (49) 7031-637-850 http://www. honeywell. de/fema Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL DPTM50D-5000D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL DPTM50D-5000D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag