User manual HONEYWELL EXCEL 800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL EXCEL 800. We hope that this HONEYWELL EXCEL 800 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL EXCEL 800.


Mode d'emploi HONEYWELL EXCEL 800
Download

You may also download the following manuals related to this product:

   HONEYWELL EXCEL 800 DATASHEET (4269 ko)
   HONEYWELL EXCEL 800 SOFTWARE DESCRIPTION (591 ko)
   HONEYWELL EXCEL 800 INTERFACE DESCRIPTION (695 ko)

Manual abstract: user guide HONEYWELL EXCEL 800

Detailed instructions for use are in the User's Guide.

[. . . ] Excel 800 SYSTEM HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION AND COMMISSIONING INSTRUCTIONS CONTENTS Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 General Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Information as per EN60730-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Terminals 71, 72 and 75, 76 must be all connected either to Panel Bus I/O modules or to LONWORKS Bus I/O modules. 55 Modem interface, Tx LED (1) and Rx LED (2) Modem LEDs on RJ45 socket Tx (1) flickering The controller is transmitting data to the HMI, e. g. , XI582 or XI882A Rx (2) flickering The controller is receiving data from the HMI Table 37 HMI interface LEDs Fig. 56 I/O Bus switch S2 Communication S2 setting LONWORKS Bus only Panel Bus and LONWORKS Bus LONWORKS BUS modules connected to terminals 11 . . . . 14 of the controller Panel Bus connected to terminals 71, 72 or 75, 76 of the controller Table 39 I/O Bus switch settings LON Panel Modem Signals on RJ45 socket Pin Signal type 1 2 3 4 5 6 7 8 Carrier detect Receive Transmit Data terminal ready Signal ground 5V Clear to send Panel Table 38 Signals of the modem interface Communication Speed Default setting: 9600 baud The communication speed can be set to as high as 38. 4 Kbaud, e. g. , using the HMI (XI852 or XI882A) or a Laptop with XL-Online, see Appendix 2. 37 EN1B-0375GE51 R0709 Description of the XCL8010 Controller Module Excel 800 C-Bus Termination Switch S1 The XCL8010 Controller Module features a 3-position C-Bus termination switch S1. This switch must be set in accordance with the given C-Bus configuration. Fig. 57 C-Bus termination switch Switch setting S1 Baud rate Up to 9600 baud (default setting) 9. 6k all 76k mid 76k end Up to 76800 baud without bus termination Up to 76800 baud with bus termination controller at the end of the C-Bus Table 40 XCL8010 C-Bus termination switch S1 settings Memory Memory Size Usage SRAM 512 KB For controller application, modem trend and firmware RACL application: 128 KB Total application: 192 KB Flash EPROM 2 MB 128 KB Firmware (1 MB) and application (1 MB) storage For bootstrap loader Table 41 XCL8010 memory Note The XCL8010 Controller Module does not contain a battery. RAM (data and realtime clocktime) is buffered for 3 days by a super capacitor. EN1B-0375GE51 R0709 38 Excel 800 Description of the I/O Modules Description of the I/O Modules Common Features Switches located on the Terminal Socket Feature Function Analog Input Modules Types of Analog Input Modules, Terminal Socket Type Description Housing Service · LED test, see section "Troubleshooting" button S1 on page 73 (pluggable I/O · LONWORKS service button functionality modules, for LONWORKS Bus I/O modules only) Hex switch S2 · Module addressing for Panel Bus I/O modules XF821 XFL821 XS821-822 XSU821-822 Panel Bus analog input module LONWORKS Bus analog input module Terminal socket Light-gray Dark-gray Light-gray Table 42 Excel 800 Analog Input Modules LEDs located on the I/O Module Feature Function · Service information, see section "Troubleshooting" on page 73 · Information on power supply, see section "Troubleshooting" on page 73 Service LED (yellow) Power LED (green) Features · 8 analog inputs · Sensor-break and short-circuit detection, see section "Troubleshooting" on page 73. For the location of these elements, see figures of the relative modules. Fig. 58 Legend XF821 Analog Input Module with terminal socket 1 2 3 4 Service button S1 Hex switch S2 Service LED Power LED Functionality of service LED and power LED: see Table 77 to Table 79 on page 77 and following. 39 EN1B-0375GE51 R0709 Description of the I/O Modules Excel 800 Terminals 72 COM B 73 74 24 V~ 24 V~0 Technical Data COM A COM B 24 V~ 24 V~0 71 COM A 75 76 77 78 Input · 0(2) . . . 20 mA (via external 499 /0. 25% resistor · NTC20k (-50. . . +150 °C; default) · PT1000-1 (-50. . . +150 °C) · PT1000-2 (0. . . +400 °C) · PT3000 (-50. . . +150 °C) · BALCO500 (-30. . . +120 °C) · NTC10k (-30. . . +100 °C) · NI1000TK5000 (-30. . . +130 °C) · Slow binary input VAUX VAUX AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI8 AI2 12 3 4 5 6 7 8 21 22 GND GND GND GND GND GND GND GND GND GND 9 10 11 12 13 14 15 16 17 18 25 26 Protection Resolution Accuracy Protected against failure voltage (24 VAC, 40 VDC) 16-bit resolution ±75 mV (0 . . . 59 Terminal assignment and internal connections of analog input modules Table 44 Analog input modules data Terminal SIGNAL Comment Balco500(1 NTC20k (default) 72, 76 73, 77 74, 78 1. . . 8 9. . . 18 21, 22 25, 26 COM b 24 V~ 24 V~0 GND 10 VDC/ 5 mA, ±2% Power supply Power supply Ground. All grounds are internally connected internally to each other. for supplying setpoint potentiometers) Shield connection (functional earth), internally connected to the DIN rail -50. . . -20 °C (-58. . . -4 °F) -20. . . 0 °C (-4. . . +32 °F) 0. . . 30 °C (32. . . 86 °F) 30. . . 70 °C (86. . . 158 °F) AI1 . . . AI8 Analog inputs 1. . . 8 1. 2 K 0. 7 K ­ ­ 1. 2 K 1. 2 K 5. 0 K 5. 0 K 1. 2 K 0. 7 K 0. 7 K 1. 0 K 1. 0 K 0. 7 K 0. 5 K 0. 5 K 0. 5 K 0. 5 K 0. 3 K 0. 5 K 0. 5 K 0. 7 K 0. 7 K 0. 7 K 0. 7 K 0. 5 K 0. 5 K 0. 7 K Table 43 Description of analog input module terminals Notes · Shield connection to be used for shielded I/O cables only. It is not allowed to connect a LONWORKS shield, since LONWORKS requires a resistor and a capacitor. · If additional shield terminals are needed, the XS814 Auxiliary Terminal Package can be installed. 70. . . 100 °C 1. 2 K 1. 2 K 1. 2 K 1. 2 K 1. 0 K 1. 0 K 1. 2 K (158. . . 212 °F) 100. . . 130 °C 1. 2 K 1. 2 K 1. 2 K 1. 2 K 3. 0 K (212. . . 266 °F) 130. . . 150 °C 1. 2 K 1. 2 K (266. . . 302 °F) 150. . . 400 °C (302. . . 752 °F) (1 (2 (3 PT3000 2-wire communication bus (LON/Panel Bus) Range NTC10k ­ ­ ­ PT1000-1 PT1000-2 (2 71, 75 COM a 2-wire communication bus (LON/Panel Bus) 1. 2 K ­ ­ 1. 2 K 5. 5 K ­ 1. 2 K ­ ­ ­ Balco specified for -30 °C . . . +120 °C, only NTC10k specified for -30 °C . . . +100 °C, only NI1000TK5000 specified for -30 °C . . . +130 °C, only Table 45 Accuracy of analog input sensors Note The accuracy of the sensor itself is not included in this table. EN1B-0375GE51 R0709 40 NI1000TK5000(3 ­ Excel 800 Description of the I/O Modules Internal Impedance when Connecting Sensors Fig. 60 Analog input low impedance (input circuit for PT1000, Balco500, PT3000, NI1000TK5000, slow binary input) Fig. 61 Analog input high impedance (input circuit for voltage input for active sensors) Fig. 62 Analog input impedance setpoint (input circuit for NTC10k, NTC20k, wall module setpoint) 41 EN1B-0375GE51 R0709 Description of the I/O Modules Excel 800 Connection Examples Active Sensor and Potentiometer Fig. 63 Analog input module, wiring example 1 For fusing specifications see section "Fusing Specifications" on page 10. EN1B-0375GE51 R0709 42 Excel 800 Description of the I/O Modules Passive Sensor and 0 (4) . . . [. . . ] [°C] Resistance [] Terminal voltage [V] -30. 0 -29. 0 -28. 0 -27. 0 -26. 0 -25. 0 -24. 0 -23. 0 -22. 0 -21. 0 -20. 0 -19. 0 -18. 0 -17. 0 -16. 0 -15. 0 -14. 0 -13. 0 -12. 0 -11. 0 -10. 0 -9. 0 -8. 0 -7. 0 -6. 0 -5. 0 -4. 0 -3. 0 -2. 0 -1. 0 0. 0 1. 0 2. 0 3. 0 4. 0 5. 0 6. 0 7. 0 8. 0 9. 0 397 399 401 403 404 406 408 410 412 413 415 417 419 421 423 425 426 428 430 432 434 436 438 440 442 444 445 447 449 451 453 455 457 459 461 463 465 467 469 471 0. 157 0. 158 0. 158 0. 159 0. 160 0. 160 0. 161 0. 162 0. 163 0. 163 0. 164 0. 165 0. 165 0. 166 0. 167 0. 168 0. 168 0. 169 0. 170 0. 171 0. 171 0. 172 0. 173 0. 174 0. 174 0. 175 0. 176 0. 176 0. 177 0. 178 0. 179 0. 179 0. 180 0. 181 0. 182 0. 183 0. 183 0. 184 0. 185 0. 186 10. 0 11. 0 12. 0 13. 0 14. 0 15. 0 16. 0 17. 0 18. 0 19. 0 20. 0 21. 0 22. 0 23. 0 24. 0 25. 0 26. 0 27. 0 28. 0 29. 0 30. 0 31. 0 32. 0 33. 0 34. 0 35. 0 36. 0 37. 0 38. 0 39. 0 40. 0 41. 0 42. 0 43. 0 44. 0 45. 0 46. 0 47. 0 48. 0 49. 0 473 475 477 479 481 483 485 487 489 491 493 495 497 499 501 503 506 508 510 512 514 516 518 520 522 524 527 529 531 533 535 537 539 542 544 546 548 550 553 555 0. 186 0. 187 0. 188 0. 189 0. 190 0. 190 0. 191 0. 192 0. 193 0. 193 0. 194 0. 195 0. 196 0. 196 0. 197 0. 198 0. 199 0. 200 0. 201 0. 201 0. 202 0. 203 0. 204 0. 205 0. 205 0. 206 0. 207 0. 208 0. 209 0. 210 0. 210 0. 211 0. 212 0. 213 0. 214 0. 215 0. 215 0. 216 0. 217 0. 218 50. 0 51. 0 52. 0 53. 0 54. 0 55. 0 56. 0 57. 0 58. 0 59. 0 60. 0 61. 0 62. 0 63. 0 64. 0 65. 0 66. 0 67. 0 68. 0 69. 0 70. 0 71. 0 72. 0 73. 0 74. 0 75. 0 76. 0 77. 0 78. 0 79. 0 80. 0 81. 0 82. 0 83. 0 84. 0 85. 0 86. 0 87. 0 88. 0 89. 0 557 559 561 564 566 568 570 572 575 577 579 581 584 586 588 590 593 595 597 600 602 604 607 609 611 614 616 618 621 623 625 628 630 632 635 637 639 642 644 647 0. 219 0. 220 0. 220 0. 221 0. 222 0. 223 0. 224 0. 225 0. 226 0. 226 0. 227 0. 228 0. 229 0. 230 0. 231 0. 231 0. 233 0. 233 0. 234 0. 235 0. 236 0. 237 0. 238 0. 239 0. 240 0. 241 0. 241 0. 242 0. 243 0. 244 0. 245 0. 246 0. 247 0. 248 0. 249 0. 249 0. 250 0. 251 0. 252 0. 253 90. 0 91. 0 92. 0 93. 0 94. 0 95. 0 96. 0 97. 0 98. 0 99. 0 100. 0 101. 0 102. 0 103. 0 104. 0 105. 0 106. 0 107. 0 108. 0 109. 0 110. 0 111. 0 112. 0 113. 0 114. 0 115. 0 116. 0 117. 0 118. 0 119. 0 120. 0 649 651 654 656 659 661 664 666 668 671 673 676 678 681 683 686 688 691 693 696 698 701 703 706 708 711 713 716 718 721 724 0. 254 0. 255 0. 256 0. 257 0. 258 0. 259 0. 260 0. 261 0. 261 0. 262 0. 263 0. 264 0. 265 0. 266 0. 267 0. 268 0. 269 0. 270 0. 271 0. 272 0. 273 0. 274 0. 275 0. 276 0. 276 0. 278 0. 278 0. 280 0. 280 0. 281 0. 283 EN1B-0375GE51 R0709 84 Excel 800 Appendix 3: Sensor Characteristics NTC 20 k Temp. [°C] Resistance [k] Terminal voltage [V] Temp. [°C] Resistance [k] Terminal voltage [V] Temp. [°C] Resistance [k] Terminal voltage [V] Temp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EXCEL 800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EXCEL 800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag