User manual HONEYWELL EXCEL SMART I-O COMPACT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL EXCEL SMART I-O COMPACT. We hope that this HONEYWELL EXCEL SMART I-O COMPACT user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL EXCEL SMART I-O COMPACT.


Mode d'emploi HONEYWELL EXCEL SMART I-O COMPACT
Download
Manual abstract: user guide HONEYWELL EXCEL SMART I-O COMPACT

Detailed instructions for use are in the User's Guide.

[. . . ] NOTE: All relay and power supply terminal blocks are orange-colored. NOTE: According to VDE guidelines, it is not allowed to mix low-voltage and high-voltage signals on the relays. The Excel Smart I/O Compact is equipped with an adhesive terminal assignment label on the top of the housing (see Fig. Overview of terminals and functions terminal # function removable LONWORKS connection plug digital input #1 analog input #1 analog input #2 GND terminals serving all signals digital input #2 digital input #3 analog input #3 not used relay common for relays 1, 2, and 3 relay #1, normallyopen contact relay #2, normallyopen contact relay #3, normallyopen contact not used removable power supply plug 230 Vac 24 Vac X X X X X X X X model XFCL2A1 The Excel Smart I/O Compact can be mounted onto the DIN rail simply by snapping it into place. [. . . ] 5. LonWorks Communications General Information The Excel Smart I/O Compact is equipped with a freetopology transceiver for communication on LONWORKS® networks. The LONWORKS network is insensitive to polarity, eliminating the possibility of installation errors due to miswiring. Different network configurations (daisy-chain, loop, and star configurations, or any combination thereof) are possible (see also Excel 50/500 LONWORKS Mechanisms Interface Description, EN0B-0270GE51). Connecting to the LONWORKS Network IMPORTANT Do not bundle wires carrying field device signals or LONWORKS communications together with highvoltage power supply or relay cables. separation of 3 inches (76 mm) between such cables. Local wiring codes may take precedence over this recommendation. IMPORTANT Try to avoid installing in areas of high electromagnetic noise (EMI). The unit must be wired to the LONWORKS network using level IV 22 AWG (Belden part number 9D220150) or plenum-rated level IV 22 AWG (Belden part number 9H2201504) nonshielded, twisted-pair, solid-conductor wire. When possible, use Honeywell 111AK3781, AK3782, AK3791, or AK3792 cable (US part numbers). See Excel 50/5000 LONWORKS Mechanisms, EN0B-0270GE51, for details, including maximum lengths. Use wire with a minimum size of 20 AWG (0. 5 mm2) and a maximum size of 14 AWG (2. 5 mm2). Excel Smart I/O Compact XFCL2A1 Excel Smart I/O Compact XFCL3A1 device 3 device 2 device 1 230 Vac 25 230 Vac 26 device 2 device 1 24 Vac 25 24 Vac 26 230 Vac 25 230 Vac 26 24 Vac 25 24 Vac 26 230 Vac 25 230 Vac 26 24 Vac (+/-20%) N L N L 230 Vac (15% / +10%) 50 / 60 Hz 230 Vac (15% / +10%) 50 / 60 Hz Fig. Connection to power supply NOTE: Do not reverse the polarity of the power connection cables, and avoid ground loops (i. e. avoid connecting one field device to several controllers) as this may result in short circuits damaging your device. Excel Smart I/O Compact D-71101 Schönaich Made in Germany Excel Smart I/O Compact D-71101 Schönaich Made in Germany 12 12 termination module Fig. Connection to LonWorks network and termination module (here: daisy-chain network configuration) The Excel Smart I/O Compact is connected to the LONWORKS network via a removable terminal plug (attached to terminals 1 and 2) permitting individual Excel Smart I/O Compacts to be connected / disconnected from the LONWORKS network without disturbing the operation of other devices. XFCL2A1 with 230 Vac Power Supply The XFCL2A1 with 230 Vac power supply is equipped with a built-in 24 Vac transformer. Power supply: 230 Vac [-15% / +10%], 50/60 Hz). Power consumption: < 6 VA (device unloaded) 3 EN1B-0282GE51 R0305B EXCEL SMART I/O COMPACT Depending upon the chosen network configuration, one or two terminations (see section "LONWORKS Termination" on page 6) may be required. Analog Inputs The Excel Smart I/O Compact is equipped with three analog inputs. The analog inputs may be used as NTC20k temperature sensor inputs or as slow digital inputs. The analog inputs do not support 0. . . 10 V input. Slow digital input characteristics Inputs/Outputs Wiring the Inputs/Outputs Use a minimum size of 20 AWG (0. 5 mm ) and a maximum of 14 AWG (2. 5 mm2) for all input/output connections. The maximum length of all input/output cables is 400 m. Two wires with a total thickness of 14 AWG can be twisted together and connected using a wire nut (include a pigtail with this wire group and attach the pigtail to the individual terminal block). Deviations from this rule can result in improper electrical contact. Local wiring codes may take precedence over this recommendation. 2 software de- resistive input tects inputs as (dry contact) closed open < 200 > 50 k high/low switching at < 1. 5 Vdc > 3. 5 Vdc current out of terminal < 0. 3 mA < 0. 1 mA Table 4. [. . . ] See Table 5 for a description of the meaning of the various different possible behaviors of the LONWORKS service LED. For more information on standard service LED behavior, refer to Motorola LONWORKS Technology Device Data Manual, page AL-190. 6d 7 8 Possible Problems and Recommended Actions Check to see if the LONWORKS service LED's behavior is changed when you switch the power OFF/ON. Please contact Honeywell if this does not solve the problem. 9 LED flashes continuously in following pattern: 4x Neuron communication failure or ON/OFF followed by 5 sec sensor break. pause. 5 EN1B-0282GE51 R0305B EXCEL SMART I/O COMPACT Accessories order no. : Terminal Protection Cover Required for wall/ceiling mounting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EXCEL SMART I-O COMPACT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EXCEL SMART I-O COMPACT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag