User manual HONEYWELL F PLUS ED 1 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL F PLUS ED 1. We hope that this HONEYWELL F PLUS ED 1 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL F PLUS ED 1.


Mode d'emploi HONEYWELL F PLUS ED 1
Download
Manual abstract: user guide HONEYWELL F PLUS ED 1DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] For further details see Datasheet AZ. Pressure FN. . . + ED 1 Differential pressure FHBN. . . + ED 1 Characteristic of a transmitter (nominal range) Product Summary Operating range (nominal range) P0­PN Smallest adjustable operating range Max. Sensor permissible material pressure (approx. values) Type Overpressure 0 ­ 50 mbar 0 ­ 100 mbar 0 ­ 250 mbar 0 ­ 500 mbar 0­ 1 bar 0­ 2. 5 bar Vacuum ­1 to 0 ­1 to 1 ­1 to 5 ­250 to+250 20 25 65 125 250 0. 7 mbar mbar mbar mbar mbar bar 2. 5 bar 5 bar 6 bar 6 bar 6 bar 16 bar 1. 4104 + 1. 4571 FN FN FN FN FN FN 505 + 510 + 025 + 05 + 1+ 3+ ED ED ED ED ED ED 1 1 1 1 1 1 bar bar bar mbar 250 500 1. 5 125 mbar mbar mbar mbar 6 6 25 3 bar bar bar bar 1. 4104 + 1. 4571 FVN FVN FVN FVN 111 + 112 + 105 + 125 + ED ED ED ED 1 1 1 1 Differential pressure 0 ­ 500 mbar 0­ 1 bar 0­ 2. 5 bar 0­ 5 bar 0 ­ 10 bar 125 mbar 250 mbar 0. 7 bar 1. 25 mbar 2. 5 mbar 10 15 15 15 25 bar bar bar bar bar 1. 4305 + 1. 4571 FHBN FHBN FHBN FHBN FHBN 05 1 3 5 10 + ED 1 + ED 1 + ED 1 + ED 1 + ED 1 + Accessories AZ 331 APV 630 · Plug-in display module · Programmable display For differential pressure · Valve combination VKD 3, VKD 5 · Threaded joint with male adapter union MAU 8 i Note · If measured values diverge due to higher static (system) pressure, observe the adjustment instructions on page 71. s Degree of protection: IP 65 70 Pressure transmitters Ty p e s e r i e s F Te c h n i c a l d a t a Supply voltage Power consumption Outputs (short-circuit proof) 24 V AC ± 20% or 24­36 V DC Signal and supply voltage is connected to the sensor module. [. . . ] ­20 to +70°C Load impedance Direction of action Output signal 0­10 V and 0­20 mA Operating mode Sensor element Pressure connection Cable entry Degree of protection Installation Materials Linearity Hysteresis All plugged-in modules are powered via the terminal strip of the sensor module (on ED 1) or via the plug connection. The output signal is sent from each module for further evaluation via the same route. The power consumption increases by approx. 1 W for each additional module plugged in. Long-term drift Repetition accuracy Accuracy class Temperature drift Influence of static pressure Mounting position Ambient temperature Max. medium temperature Connection schemes Terminal connection Storage temperature Plug connection !Important: When connecting to control systems with a common AC supply, the ground conductor must be looped through. That is to say, on all devices in the system, the same reference potential must be present at the corresponding ground terminal (terminal 2). In the case of a DC supply, ensure correct polarity. ED 3 output signal 0­10 V Pressure transmitters 71 Ty p e s e r i e s F Adjustment and operation Operating ranges and output signals are adjustable over a wide range. An outstanding characteristic of the pressure transmitters is the variability of the characteristic curve, which means that the pressure range and output signal can be adapted to any subsequent control system. P0 = starting pressure of nominal range PN = nominal pressure (end point of nominal range) PA = starting pressure of set range PE = end pressure of set range Operator interface ED 1 1 = Setting spindle for setting the final value PE 2 = Setting potentiometer for setting the initial value PA 3 = Slide switch for selecting the output signal 0­20 mA (0­10 V) or 4­20 mA (2­10 V) 4 = Slide switch for inverting the output signal 5 = Slide switch for changing the steepness of the characteristic in a ratio of 8:5. Normal position: 8 For smaller operating ranges (< approx. 70% of the nominal range), select position 5 6 = Plug connector for further evaluation modules Output signals for module ED 1 Basic setting The factory default setting covers the nominal range P0 (usually 0 bar) to PN. Altering the range The range can easily be altered by shifting the end point and adjusting the steepness of the characteristic curve. Inversion The output signal can be inverted by means of a slideswitch. Operator interface ED 3 1 = Setting spindle for setting the final value PE 2 = Setting potentiometer for setting the initial value PA 4 = Slide switch for inverting the output signal 6 = Plug connector for further evaluation modules Output signals for module ED 3 Range alteration and inversion as above. The current signal can be reduced below 4 mA (down to approx. If the installation has a fault alarm system, the response threshold should be set below 2. 5 mA. 72 Pressure transmitters Ty p e s e r i e s F Setting and testing Altering the operating range To check functioning or change the settings from outside the system, a test set-up is required which meets the following requirements: 1. It must be possible to apply pressure to the pressure transmitter up to the desired final value. The pressure must be displayed by a sufficiently accurate pressure gauge. To display the output signal a voltmeter with a measuring range of 0­10 V (preferably 0­15 V) or an ammeter with a measuring range of 0­20 mA (preferably 0­25 or 0­30 mA) are required. To supply power to the transmitter, a 24 V AC or 24 V DC voltage source is needed. Setting operations must be carried out in the correct sequence 1. Set the slide switches (3) and (4) to the correct position (switch 3 is only present on ED 1) Switch (3): Output signal 0­10 V / 0­20 mA or 4­20 mA / 2­10 V (only on ED 1) Switch (4): Direction of action Switch up rising pressure = rising output signal Switch down (INV): rising pressure = falling output signal 3. [. . . ] A differential pressure must not be active, i. e. Remove the plastic cover and check slide switches 3 + 4. The FHBN is supplied with the correct voltage and the output voltage is displayed. Loosen the spindle locking screw above the inspection window. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL F PLUS ED 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL F PLUS ED 1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag