User manual HONEYWELL F50F DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL F50F. We hope that this HONEYWELL F50F user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL F50F.


Mode d'emploi HONEYWELL F50F
Download
Manual abstract: user guide HONEYWELL F50FDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] ELECTROSTATIC AIR CLEANER PRODUCT DATA F50F FEATURES · · · · · · · · · · Available in two sizes to suit most standard duct sizes Adaptable to suit airflow from either side One or two electrostatic cells depending on cabinet size Pressure drop approximately equal to that of an average fibreglass filter Neon indicator light tells if the Air Cleaner is powered and if high voltage is present Performance jumper allows operation with reduced ozone production Solid state self regulating power pack Test button checks system operation High efficiency, commercial grade collecting cells provide excellent dirt holding capacity Approvals - meets all relevant EU directives DESCRIPTION The high efficiency F50F Electronic Air Cleaner is mounted in the return air duct of a forced air heating, cooling or ventilation system. [. . . ] Firstly a high voltage is applied to the stream of air in the ionising stage. This charges the dirt particles which are then attracted onto oppositely charged plates in the collecting stage, similar to the way in which iron filings are attracted to a magnet. The cleaned air is then ducted back into the room or living space. Weight Model F50F1008 F50F1024 Weight Shipping Weight Installed Weight Shipping Weight Installed Weight Approvals : kg 17. 2 15. 0 11. 3 9. 5 After a period of time the cell can be removed and the collected dirt washed off with water and detergent. Meets all relevant EU Directives DIMENSIONS Two-stage electrostatic precipitation APPLICATION The F50F range of Electrostatic Air Cleaners is designed for use in forced air heating, cooling and ventilating systems in offices, bars, restaurants and other commercial and public buildings. The Air Cleaner should be mounted in the return air duct close to the fan so that it can help keep the fan motor and evaporator coils clean thus reducing maintenance. Model F50F1008 F50F1024 Dim. A 475 475 Dim. B 515 513 Dim. C 600 282 Dim. D 650 333 Dim. E 70 92 All dimensions in millimetres EN0R 8478 R1 2 F50F ELECTROSTATIC AIR CLEANER INSTALLATION AND LOCATION Note 1. For most efficient air cleaning, air flow must be spread evenly across the face of the air cleaner. Do not mount in the discharge air duct. Turning Vanes If the Air Cleaner is installed close to an elbow or angle fitting, install turning vanes inside the angle to distribute airflow more evenly across the face of the cell. Determine Duct Design Requirements The Air Cleaner is adaptable to all new and existing forced air heating, cooling and ventilating systems used in commercial buildings. Transitions, turning vanes, or offsets may be needed in some applications for effective operation. Choose a location that is readily accessible for regular inspection and cleaning. [. . . ] This test gives the most accurate comparison of high efficiency filtration for sub-micron particles. Pressure Drop Pa Efficiency % AIR FLOW m /hr 3 3 EN0R 8478 R1 F50F ELECTROSTATIC AIR CLEANER WIRING To W8600E Wall Panel (Optional) ON/OFF Switch Interlock Switch Power Pack Models featuring 2 Electrostatic Collecting Cells Air Flow Switch Board Performance Jumper Resistor for W8600E wash indication threshold Air flow switch disable jumper ORDERING SPECIFICATION Model F50F1008 F50F1024 Cells 2 1 To Fit Standard Duct (mm) 600 x 450 250 x 450 Maximum Airflow (m /h) 3400 1700 3 Honeywell Control Systems Limited Newhouse Industrial Estate Motherwell ML1 5SB United Kingdom EN0R 8478 R1 Helping You Control Your World [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL F50F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL F50F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag