Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL F76CS. We hope that this HONEYWELL F76CS user guide will be useful to you.
Lastmanuals help download the user guide HONEYWELL F76CS.
You may also download the following manuals related to this product:
HONEYWELL F76CS SPECIFICATION DATA (494 ko)
Manual abstract: user guide HONEYWELL F76CS
Detailed instructions for use are in the User's Guide.
[. . . ] Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. Immediately rectify any malfunctions which may influence safety. Installation position Operating pressure Vertical or horizontal, with filter bowl downwards Minimum 1. [. . . ] During reverse rinsing, an inlet pressure of at least 1. At the latest every 2 months, reverse rinsing should be carried out according to DIN 1988, Part 8. to ensure convenient and regular adherence to the reverse rinsing interval , we recommend installing an automated reverse rinsing system Z11S. Filtered water can also be tapped during reverse rinsing. If reverse rinsing water is not to be discharged via a direct connection, a collecting container must be positioned beneath before reverse rinsing. Open ball valve by turning the reverse rinsing button to the stop point o Select bar must be upright o The patented reverse rinsing system starts o When filtering with Double Spin Technology, a visual function check is possible through the rotating red rotor 2. Repeat procedure three times o If the filter is extremely dirty, the procedure may have to be repeated additional times With aid of the memory ring, the next deadline for manual reverse rinsing can be booked. The reverse rinsing water must be routed to the drain channel in such a way that no backwater can occur. Direct connection: o Connector DN 50/70 as well as the necessary pipes and siphon (3 elbows 90°) in DN 70. *at 4 bar inlet pressure and 3 x 3 seconds reverse rinsing duration The automated system reliably takes over reverse rinsing of the filter at intervals which can be set between 4 minutes and 3 months. Close shutoff valve on inlet Release pressure on outlet side (e. Through water tap) Close shutoff valve on outlet Loosen slotted screw o Do not remove slotted screw Slacken tension in compression spring o Turn control handle to the left (-) until it does not move any more Slowly open shutoff valve on inlet Turn control handle until the setting scale shows the desired value Retighten slotted screw Slowly open shutoff valve on outlet We recommend a planned maintenance contract with an installation company In accordance with DIN 1988, part 8, the following measures must be taken: Interval: once a year 1. Check back pressure using a pressure meter when there is zero through-flow o If the pressure is increasing slowly, the valve may be dirty or defective. In this instance, carry out servicing and cleaning 3. Interval: every 2 months · The filter must be cleaned by reverse rinsing regularly, at the latest every 2 months · Non-compliance can lead to the filter becoming blocked This results in a drop in pressure and decreasing water flow · the filter meshes are made of stainless steel. A red coating as a consequence of rust from the pipelines has no influence on function or the way the filter works Do not forget to do a visual check of the ball valve. Loosen slotted screw o Do not remove slotted screw 5. Interval: every 2 months · The filter must be cleaned by reverse rinsing regularly, at the latest every 2 months · Non-compliance can lead to the filter becoming blocked This results in a drop in pressure and decreasing water flow · the filter meshes are made of stainless steel. [. . . ] To be carried out by an installation company or the operator. Detergents must not be allowed to enter the environment or the sewerage system!Red bronze housing Red bronze connector piece High-quality synthetic material spring bonnet High-quality synthetic material valve insert Stainless steel fine filter Shock-resistant, clear transparent synthetic material filter bowl · A new setting can be achieved using a pressure gauge. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL F76CS
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL F76CS will begin.