Manual abstract: user guide HONEYWELL FY69P

Detailed instructions for use are in the User's Guide.

[. . . ] FY69P Grey cast iron Y-strainer with flange connections Product specification sheet Application FY69P strainers are used in commercial and industrial applications, as well as for central water supply systems within the limits of their specifications. [. . . ] Accumulated dirt particles can then easily be removed during programmed cleaning of the strainer. In addition, if a service valve is fitted instead of the blanking plug, collected dirt and/or condensate in compressed air systems can be flushed out without difficulty. Options FY69P-. . . A = With double sieve, mesh size approx. 0. 50 mm Connection size Connection size Weight Dimensions DN approx. kg mm L H R F 15 2. 0 130 64 3/ " 8 95 1. 4 20 2. 6 150 83 3/ " 8 105 1. 5 25 3. 8 160 90 3/ " 8 115 1. 5 32 6. 3 180 108 3/ " 8 140 1. 6 40 7. 4 200 120 3/ " 8 150 1. 6 50 10. 4 230 143 3/ " 8 165 1. 8 65 15 290 179 1/ " 2 185 1. 9 80 22 310 203 1/ " 2 200 1. 7 100 30 350 222 1" 220 1. 8 125 45 400 267 1" 230 1. 9 150 66 480 320 1" 285 1. 7 200 144 600 382 1" 340 1. 7 Zeta value 90 www. honeywell. com EN0H-1124GE23 R1009 · Subject to change FY69P Grey cast iron Y-strainer Installation Example Installation Guidelines · If possible install in horizontal pipework with blanking plug downwards o This position ensures optimum cleaning efficiency o Where installed in rising pipework dirt particles will not collect in strainer Install shutoff valves o Enables fast cleaning of the strainer Ensure good access o So that the sieve can be easily removed o Simplified maintenance and cleaning Typical Applications Strainers of this type are essential on inlet pipework to appliances and systems. They can be used for commercial and industrial applications within the limits of their specifications. Strainers must be fitted: · · · Where the presence of dirt can cause premature wear in machines or systems Where it is possible that appliances or systems can become blocked Where the ingress of dirt particles can cause corrosion · · Inspection and Maintenance EN0H-1124GE23 R1009 · Subject to change DIN 1988, Part 8 specifies that the following operations be carried out regularly. A scheduled maintenance scheme is recommended. [. . . ] EN0H-1124GE23 R1009 Subject to change without notice © 2009 Honeywell GmbH [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL FY69P

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL FY69P will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag