Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL KOMBI-FC. We hope that this HONEYWELL KOMBI-FC user guide will be useful to you.
Lastmanuals help download the user guide HONEYWELL KOMBI-FC.
You may also download the following manuals related to this product:
HONEYWELL KOMBI-FC DATASHEET (502 ko)
Manual abstract: user guide HONEYWELL KOMBI-FC
Detailed instructions for use are in the User's Guide.
[. . . ] The V5012C Kombi-DP diaphragm unit can be fitted to the Kombi-Valves at any time, even when the system is under pressure and in operation operation of the system does not have to be interrupted to install the V5012C Kombi-DP.
Features
· Retrofittable without interrupting operation of the system · Rugged design · Two pre-setting ranges available: 0. 1. . . 0. 3 bar or 0. 3. . . 0. 6 bar differential pressure · Suitable for V5010 Kombi-3-plus BLUE DN10. . . DN40 and V5032 Kombi-2-plus DN15. . . DN40
Design
The diaphragm unit consists of: · Diaphragm housing with connections for impulse tube and valve · Spindle and tappet · Supply valve adapter to install impulse tube to supply mains valve (suitable for V5000 Kombi-3-plus RED and V5100 Stop Valve-3) · 4 x 1 mm impulse tube with compression fittings, length 800 mm · 4 mm Allan key to change the pre-setting
Specifications
Medium pH-value Operating temperature Operating pressure Differential pressure Differential pressure pre-setting range Water or glycol-water mixture, quality to VDI 2035 8. . . 9. 5 2. . . 130°C (36. . . 266°F) max. 2. 0 bar (29 psi) V5012C0103: 0. 1. . . 0. 3 bar (1. 45. . . 4. 35 psi) V5012C0306: 0. 3. . . 0. 6 bar (4. 35. . . 8. 70 psi) Factory setting kvs (cv)-values V5012C0103: 0. 1 bar (1. 45 psi) V5012C0306: 0. 3 bar (4. 35 psi) see flow diagram and remarks on page 5
Materials
· Diaphragm housing, spindle and diaphragm spring made of stainless steel · Connection for impulse tube and valve, supply valve adapter, compression fittings and tappet made of brass · Diaphragm and soft seals made of EPDM · Impulse tube made of copper
Honeywell · All rights reserved
EN0H-0281GE25 R0805
V5012C KOMBI-FC
Function
The V5012C Kombi-DP diaphragm unit is installed onto a V5010 Kombi-3-plus or V5032 Kombi-2-plus return mains balancing valve and connected to a supply mains valve with the supplied 4 x 1mm copper impulse tube and compression fittings. [. . . ] Suitable supply valves are the V5000 Kombi-3-plus RED or the V5100 Stop Valve-3 which are both compatible with the supply valve adapter of the V5012C Kombi-DP kit. The pressure of the supply pipeline is led to the Kombi-DP via the impulse tube and acts onto the top of the diaphragm, the pressure of the return pipeline is led to the Kombi-DP through the return valve and acts onto the bottom of the diaphragm. When the supply pressure increases, the diaphragm inside the Kombi-DP is pushed down against the return pressure. The diaphragm acts onto the insert of the connected return valve and the flow is throttled. When the supply pressure decreases, the diaphragm inside the Kombi-DP is pushed open by the return pressure. The diaphragm moves up, releasing the insert of the return valve and the flow increases. The desired differential pressure can be preset from 0. 1. . . 0. 3 or from 0. 3. . . 0. 6 bar, depending on the type used.
Dimensions
Additional space required for optional VA2503B001 Installation space required
Additional space required for optional VA2503B001
Installation space required
Fig. In that case the control curve as displayed in Fig. 4 moves in parallel to the pre-setting value. The V5012C0306 is factory set to 0. 3 bar. The pre-setting can be increased to max. 4 moves in parallel to the pre-setting value. heating systems with unrestrichted TRVs, the flow can additionally be throttled by reducing the pre-setting value of the balancing valve. Effect of different valve pre-settings on kvs-value Pre-setting of Balancing Valve DN 10 15 20 25 32 40 1. 5 1. 50 1. 50 3. 50 3. 50 -- -- 1. 4 1. 45 1. 45 3. 40 3. 40 -- -- 1. 2 1. 35 1. 35 3. 30 3. 30 -- -- 1. 0 1. 25 1. 25 3. 10 3. 10 5. 50 5. 50 0. 8 1. 15 1. 15 2. 80 2. 80 5. 20 5. 20 0. 6 0. 95 0. 95 2. 45 2. 45 4. 45 4. 45 0. 4 0. 70 0. 70 1. 80 1. 80 -- --
NOTE: The V5010 Kombi-3-plus BLUE or V5032 Kombi-2-plus balancing valve has to be pre-set to 1. 5 (sizes DN10. . . DN25) or to 1. 0 (sizes DN32. . . DN40) when used with the V5012C Kombi-DP diaphragm unit. [. . . ] heating systems with unrestrichted TRVs, the flow can additionally be throttled by reducing the pre-setting value of the balancing valve. Effect of different valve pre-settings on kvs-value Pre-setting of Balancing Valve DN 10 15 20 25 32 40 1. 5 1. 50 1. 50 3. 50 3. 50 -- -- 1. 4 1. 45 1. 45 3. 40 3. 40 -- -- 1. 2 1. 35 1. 35 3. 30 3. 30 -- -- 1. 0 1. 25 1. 25 3. 10 3. 10 5. 50 5. 50 0. 8 1. 15 1. 15 2. 80 2. 80 5. 20 5. 20 0. 6 0. 95 0. 95 2. 45 2. 45 4. 45 4. 45 0. 4 0. 70 0. 70 1. 80 1. 80 -- --
NOTE: The V5010 Kombi-3-plus BLUE or V5032 Kombi-2-plus balancing valve has to be pre-set to 1. 5 (sizes DN10. . . DN25) or to 1. 0 (sizes DN32. . . DN40) when used with the V5012C Kombi-DP diaphragm unit. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL KOMBI-FC
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.